Addressable fire alarm systems project DC24V strobe and horn combined Specification: Operating voltage: DC24V (allowable range 20V ~ 28V) Current: Alarm Current ≤120mA @ DC24V Operating environment: Temperature...
... status indicator flashes red once per 6 seconds, alarm status indicator light is lit. Weight: about 100g Dimensions:100mmx55mm Connection: non-polarity two wire Use of the environment: indoor, ......
... indicator flashes red once per 6 seconds, alarm status indicator light is lit. Weight: about 100g Dimensions:100mmx55mm Connection: non-polarity two wire Use of the environment: indoor, ......
Addressable fire alarm systems DC24V 2 wire strobe horn,flash light with sounder Specification: Operating voltage: DC24V (allowable range 20V ~ 28V) Current: Alarm Current ≤120mA @ DC24V Operating environment: ...
Addressable fire alarm systems 24V strobe horn,flash light with hooter Specification: Operating voltage: DC24V (allowable range 20V ~ 28V) Current: Alarm Current ≤120mA @ DC24V Operating environment: Temperatur...
...addressable fire alarm systems strobe horn,flash light with hooter Specification: Operating voltage: DC24V (allowable range 20V ~ 28V) Current: Alarm Current ≤120mA @ DC24V Operating environment: Temperature...
Addressable fire alarm systems project DC24V strobe and horn combined Specification: Operating voltage: DC24V (allowable range 20V ~ 28V) Current: Alarm Current ≤120mA @ DC24V Operating environment: Temperature...
Public address system 20 CH Intelligent Alarming Interface (Y-9709 ) Micro-computer control 20 groups fire alarm short-circuit signal input, has address code, can connect 6 units(120 zones) Model:Y-9709 Power s...
Introduction A fire siren is a type of audible emergency notification device commonly used as part of a fire alarm system or emergency warning system. Here's a more detailed introduction to fire sirens: Purpose...
Introduction A fire siren is a type of audible emergency notification device commonly used as part of a fire alarm system or emergency warning system. Here's a more detailed introduction to fire sirens: Purpose...
... Address Coder For Fire Safety Smoke Alarm System Introduction The CA2080 address encoder is used for the address encode for the smoke detector, heat detector, sounder, manual call point, hydrant button, mod...
Fire Alarm System Addressable Fire Panel for Archives Support Alarm component Technical parameter: No. Product Parameter 1 Brand 2*12 Volt sealed lead acid in series 2 Place of Origin Guangzhou, Guangdong, Chin...
Introduction A monitor module is a device used in addressable fire alarm systems to interface with and monitor the status of other connected devices or systems. The key functions of an input module include: Mon...
Introduction An input module is also known as a monitor module,it is a device used in addressable fire alarm systems to interface with and monitor the status of various system components and auxiliary devices. ...
Introduction A monitor module is a device used in addressable fire alarm systems to interface with and monitor the status of other connected devices or systems. The key functions of an input module include: Mon...
Introduction An input module is also known as a monitor module,it is a device used in addressable fire alarm systems to interface with and monitor the status of various system components and auxiliary devices. ...
Addressable fire alarm systems 2 wire smoke and heat combine detector SPECIFICATIONS: Operating Voltage Range: 16 to 28 VDC Standby Current: 680A @ 24 VDC Maximum Alarm Current (LED on: ) 7 mA @ 24 VDC Operati...
...) Maximum Alarm Current (LED on: ) 7 mA @ 24 VDC Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating ......
Addressable fire alarm systems 2 wire bus output module SPECIFICATIONS: Nominal Operating Voltage: 15 to 28 VDC Standby Current: 1mA @ 24 VDC Maximum Alarm Current (LED on: ) 5 mA @ 24 VDC Maximum(NAC): Regul...
... of the activated smoke alarm. This helps expedite the response and investigation of the potential fire incident. Enhanced Monitoring and Diagnostics: The control panel can continuously monitor the status of...