| Sign In | Join Free | My burrillandco.com |
|
Standard:IEC61032 test probe 31 figure 14. Application:It is used for checking food waste disposal units of milling system of hazardous mechanical parts whether is touched or not. Test sample:Easily accessible ...
Test Probe 32 HT-I15 Standard:IEC61032 test probe 32 figure 15. Application:It is intended to verify the protection provided by fan guards against access to hazardous mechanical parts. It is equipped with nylon...
Blender Probe HT-I24 Standard:IEC60335-2-14 CI.20.102. Application:It is used to test whether the blade of hand-held stirrer is completely concealed from above and flat surface can be touched when the blade is ...
Hazardous Live Parts Probe HT-I27 Standard:IEC60065 clause 9.1.3,EN61010-1, UL3101-1 and CSA 1010-1. Application:This testing probe is used to verify the protection against access to hazardous parts through top...
Young Adult Arm Probe HT-I36 Standard:EN 50636-2-100 figure 1 and IEC 50636-2. Application:It is used to simulate the young adult to test whether the hazardous parts can be touched. Test sample:Hand held power ...
Adult Arm Probe HT-I37 Standard:EN 50636-2-100 figure 2 and EN13683-2003:clause 5.2.1.3 figure 5 Application: It is used to simulate the adult to test whether the hazardous parts can be touched. Test sample:Han...
UL Probe for Uninsulated Live Parts HT-U02 Standard: UL507-2006(PA135A)Fig 9.1, UL749 Fig 1, UL982 Fig 58.6 and UL1278 Fig 8.1(PA130A). Application:It is used for the performance of the electrical equipment enc...
Probe for Film-Coated Wire HT-U03 Standard:UL398 Fig 8.2(PA170B),UL507(PA170D),UL749 Fig 2,UL982 Fig 58.6 and UL1278 Fig 8.2(PA140A). Application:It is used for the testing of coating lines of the enamel (i.e.,...
Product Details Triangle probe UL1278 Figure 10.3 SM208 : It conforms to standard requirement of UL1278 Figure 10.3. The handle is made of nylon and the probe is made of stainless steel. The heating element and...
Product Details Rod probe UL1278 Figure 10.4 SM209 : It conforms to standard requirement of UL1278 Figure 10.4. The handle is made of nylon and the probe is made of hard steel. Reference Standard of UL1278 belo...
Product Details Product information: The test rod probe confirms to IEC61032 figure 15 requirements. It is intended to verify the protection provided by fan guards against access to hazardous mechanical parts. ...
Product Details Product details: This probe conforms to the standard requirement of UL1278 Fig 10.1. The handle is made of nylon while the probe is made of stainless steel. Standard:UL1278 Fig 10.1. Application...
Product Details Telecom Test Probe Complies With IEC60950 Figure 2C Product information: Telecom test probe complies with IEC60950 figure 2C and UL6500 figure B.1 standards. It is used for the bare parts of TNV...
Product Details Product information: The adult arm probe conforms to EN 50636-2-100 figure 2 and EN13683-2003: 5.2.1.3 fig 5. It is used to simulate the adult to test whether the hazardous parts can be touched....
UL982 PA190 Test Probes For Electrode Type Heating Appliances UL982-2006 Figure 58.5(PA190) Test Probe For Protection Test Of Portable Electrode-Type Heating Appliances Product details: It conforms to the stand...
..., or recording of functional oxygen saturation of arterial hemoglobin(SpO2), pulse rate and pulse strength for Adult, Pediatric and Neonate. Technical Specifications 1, Parameters: SpO2 and pulse rate 2, Fou...
1. Product Description : SpO2 sensor for Biolight patient monitor , Adult finger clip Biolight adult finger clip SpO2 sensor,10ft, 5pin 2. Specifications: Technical Parameter Connector type 5pin Patient end Adu...
1. Product Description : SpO2 sensor for Biolight patient monitor , Adult finger clip Biolight adult finger clip SpO2 sensor,10ft, 5pin 2. Specifications: Technical Parameter Connector type 5pin Patient end Adu...
1. Product Description : SpO2 sensor for Biolight patient monitor , Adult finger clip Biolight adult finger clip SpO2 sensor,10ft, 5pin 2. Specifications: Technical Parameter Connector type 5pin Patient end Adu...
...Finger Clip spo2 sensor 2.Model Cross References: Creative Medical K12,K15 3.Compatibility: Creative Medical K12,K15 4.Specification Monitor type Spo2 Material medical TPU Probe type Pediatric Finger Clip Wa...