...-type) with inductive position transducer (LVDT) Nominal Size NG6 (CETOP 3) Max. Operating Pressure P, A, B: 315 bar T port (return): 250 bar Rated Flow 24 L/min (at Δp = 70 bar for the...
...-type) with inductive position transducer (LVDT) Nominal Size NG6 (CETOP 3) Max. Operating Pressure P, A, B: 350 bar T port (return): 250 bar Rated Flow 40 L/min (at Δp = 70 bar for the valve) Max. Fl...
...-type) with inductive position transducer (LVDT) Nominal Size NG6 (CETOP 3) Max. Operating Pressure P, A, B: 350 bar T port (return): 250 bar Rated Flow 12 L/min (at Δp = 70 bar for the valve) Max. Fl...
...) with inductive position transducer (LVDT) Nominal Size NG6 (CETOP 3, Size 6) Max. Operating Pressure P, A, B: 350 bar T port (return): 210 bar Rated Flow 24 L/min (at Δp = 70 bar for the valve) Max....
...) with inductive position transducer (LVDT) Nominal Size NG6 (CETOP 3, Size 6) Max. Operating Pressure P, A, B: 350 bar T port (return): 250 bar Rated Flow 40 L/min (at Δp = 70 bar for the valve) Max....
... position transducer (LVDT) Nominal Size NG10 (CETOP 5, Size 10) Max. Operating Pressure P, A, B: 315 bar T port (return): 250 bar Rated Flow 100 L/min (at Δp = 70 bar for the valve) Max. Flow...
... position transducer (LVDT) Nominal Size NG10 (CETOP 5, Size 10) Max. Operating Pressure P, A, B: 315 bar T port (return): 250 bar Rated Flow 100 L/min (at Δp = 70 bar for the valve) Max. Flow...
... position transducer (LVDT) Nominal Size NG10 (CETOP 5, Size 10) Max. Operating Pressure P, A, B: 315 bar T port (return): 250 bar Rated Flow 50 L/min (at Δp = 70 bar for the valve) Max. Flow...
... position transducer (LVDT) Nominal Size NG10 (CETOP 5, Size 10) Max. Operating Pressure P, A, B: 315 bar T port (return): 250 bar Rated Flow 100 L/min (at Δp = 70 bar for the valve) Max. Flow...
... position transducer (LVDT) Nominal Size NG10 (CETOP 5, Size 10) Max. Operating Pressure P, A, B: 315 bar T port (return): 250 bar Rated Flow 100 L/min (at Δp = 70 bar for the valve) Max. Flow...
...valve (servo performance) Function 4/3-way (4 ports, 3 positions) Nominal Size NG10 (CETOP 5, Size 10) Max. Operating Pressure P, A, B: 315 bar Pilot supply (X): 315 bar T port (return): 250 bar Rated ...
...valve (servo performance) Function 4/3-way (4 ports, 3 positions) Nominal Size NG16 (CETOP 7, Size 16) Max. Operating Pressure P, A, B, X: 350 bar T port (return): 210 bar Rated Flow 200 L/min (at Δp...
...valve (servo performance) Function 4/3-way (4 ports, 3 positions) Nominal Size NG25 (CETOP 8, Size 25) Max. Operating Pressure P, A, B, X: 350 bar T port (return): 210 bar Rated Flow 370 L/min (at Δp...
...valve (seat type) Function 2-port, normally closed (P → T) Nominal Size NG6 (Size 6) Max. Operating Pressure Port P: 420 bar Port T (return): Must be depressurized to tank Adjustable Pressure Range 0 –...
... Size NG6 (Size 6) Max. Operating Pressure Port P: 420 bar Port T (return): Must be depressurized to tank Adjustable Pressure Range 0 – 200 bar (electrically proportional) Rated Flow 2 L/min (maximum ...
... Size NG6 (Size 6) Max. Operating Pressure Port P: 420 bar Port T (return): Must be depressurized to tank Adjustable Pressure Range 0 – 315 bar (electrically proportional) Rated Flow 2 L/min (maximum ...
... Size NG6 (Size 6) Max. Operating Pressure Port P: 420 bar Port T (return): Must be depressurized to tank Adjustable Pressure Range 0 – 350 bar (electrically proportional) Rated Flow 2 L/min (maximum ...
...valve (main stage spool + pilot poppet) Function 2-port, normally closed (P → T pressure limiting) Nominal Size NG6 (Size 6) Max. Operating Pressure Port P: 315 bar Port T (return): 250 bar Adjustable ...
...Nominal Size NG6 (CETOP 3, Size 6) Max. Operating Pressure Port P: 420 bar Port T (return): Must be depressurized to tank Adjustable Pressure Range 0 – 315 bar (electrically proportional) Rated Flow 2 ...
... center position flow pattern, e.g., O, M, H, etc.) Max. Operating Pressure 315 bar (Ports P, A, B) 160 bar (Port T - Return) Max. Flow Rate 60 L/min (Recommended for standard pressure drop) Port Connec...