Mini current transformer Technical Support PCB Mount Current Transformer 150A Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-875 Max. Current 10~200 A Turns Ratio 1:1000/2000/2500 ...
... Ratio 1:1000/2500/5000/10000 Primary Current 10 A Secondary Current 1/2/4/10 mA Burden (Rb) 5~100 Ω Accuracy Class 0.1/0.2/0.5 Class DC Immunity Error <3% Busbar Type as required Mounting ......
...current transformer Toroidal Current Transformer for Ammeter 1:1250 Product Description 1. Double Insulation & DC Immunity 2. Accuracy 0.1 Class, very low phase error 3. Big through hole, easy to fix and ins...
...current transformer 120A AC Current Instrument Transformer for Inrush Isolation Product Description 1. Lead wire with plug 2. Accuracy 0.1 Class, very low phase error 3. Big through hole, easy to fix and ins...
...Current Transformer for I-P close link meter ratio 1:1 KE6322 Isolation current transformer KE6322 is a two phase 1:1 current transformer, which mainly used to test I-P close link meter. It has high accuracy...
...close link meter Features: Adpot active electronic error compensation technology to realize high accuracy. Current cable is wired through perforation on the ICT Wide current dynamic range: 10mA --200A (Prima...
...Current Transformer-CT04 Series Split core Current Transformer, Current Sensor We sell several different families of current transformers (CTs) in various window sizes, current ranges, and accuracy grades. A...
... 4. Compact size Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-872 Max. Current 10~600 A Turns Ratio 1:1000/2500/5000/10000 Primary Current 10 A Secondary Current 1/2/4/10 mA B...
...current transformer Cast Resin Current Transformer for Watt Meter 120A Product Description 1. Plastic Case & DC Immunity 2. Accuracy 0.1 Class, very low phase error 3. Busbar built-in, easy to fix and instal...
...Current Transformer-CT04 Series Split core Current Transformer, Current Sensor We sell several different families of current transformers (CTs) in various window sizes, current ranges, and accuracy grades. A...
...current transformer: Excitation curve and parameters test Turns ratio test Ratio and phase error test Polarity mark check Winding resistance measurement Secondary loop burden measurement Error line curve tes...
... phase to three phase. With wide current range, it is perfect for the test of I-P close link meter. Features: High accuracy through active electronic error compensation. Direct perforated installation Wide c...
... 12 Ω Primary Current 4 mA Insulation (Winding to Body) 4 kV Secondary Voltage 20 Ω Core Materail Coiled Silicon Steel Sheet Outer ......
Zero phase current transformer Zero Sequence Current Transformer for SMPS 4KV Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-03-03B-1 Turns Ratio 1:200 Resistance 12 Ω Primary Curr...
...Current Transformer 1.rated insulation level: 12/42/75kV 2.rated frequency: 50/60Hz 3.burden power factor): COSØ=0.8 lagging 4.technical standard accords with):outdoor 5. technical standard according with:IE...