| Sign In | Join Free | My burrillandco.com |
|
...Transformer Test Bench OEM Customized Transformer Test Bed Automatic Transformer Test Bench Product Description Transformer test bench, integrated transformer test bed, transformer characteristic test bed Th...
... 1 @ 20°C RDC 6 mΩ max. DC Resistance 2 @ 20°C RDC 6.50 Ω max. Turns ratio W1 : W2 n 1 : 125 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 68 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V ...
... 6 mΩ max. DC Resistance 2 @ 20°C RDC 1.75 Ω max. Turns ratio W1 : W2 n 1 : 60 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 30 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E General...
... 6 mΩ max. DC Resistance 2 @ 20°C RDC 0.90 Ω max. Turns ratio W1 : W2 n 1 : 40 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 20 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E General...
... Ω max. DC Resistance 3 @ 20°C RDC3 4.0 mΩ max. Leakage inductance 100 kHz/ 100 mV LS 1.4 μH max. Insulation test voltage N1,2 => N3,4,5...
...Transformer For Triggering Power Thyristors D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 650 μH min. Leakage inductance 100 kHz/ 100 mV LS 2.9 μH max. DC Re...
...Transformer For power driver D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 750 μH min. Leakage inductance 100 kHz/ 100 mV LS 4.0 μH max. DC Resistance 1 RDC ...
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 370 μH min. Leakage inductance 100 kHz/ 100 mV LS 1.8 μH max. DC Resistance 1 RDC 520 mΩ max. DC Re...
...Transformer For LED D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 112 μH ±10% Turns ratio LS 3 : 1 : 0.5 ±3% Saturation current |ΔL/L| < 20% Isat 3.2 A typ. ...
...Transformer For Mobile Charger D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 150 μH ±10% Rated current ΔT = 40 K IR 1.5 A max. Saturation current |ΔL/L| < 20...
... and capacitive voltage transformers directly at the site of installation. Comprehensive Testing Functions: It performs on-site testing for voltage transformer ratio and phase angle errors, including checks ...
...250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the CT and PT Rated current: 5A, 1A Rated voltage: 100V, 110V, 115V, 120V, ......
...250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the CT and PT Rated current: 5A, 1A Rated voltage: 100V, 110V, 115V, 120V, ......
....The integrated intelligent transformer test bench produced by Wuhan Rising is mainly to test the no-load and load characteristics of electric transformer and distribution transformer, but also to test the t...
....The integrated intelligent transformer test bench produced by Wuhan Rising is mainly to test the no-load and load characteristics of electric transformer and distribution transformer, but also to test the t...
...Transformer H5015NL with RoHS Description: 17.65*12.19*4.57mm size lan transformer 10/100/1000Base-T Transformer 4 Core number transformer Small Electrical Stabilized Voltage Transformer low inductance modul...
...accord with national related protocol . It has solved the problem of big working intensity, trivial operation when on site test current transformer, voltage transformer. Meanwhile the product has a reliable ...
... for online measurement of primary current and secondary current size, conversion ratio, phase difference and polarity judgment of current transformers and transformers below 35kV.The product is composed of ...
1:0.083:0.208 Turns ratio SMPS Flyback Transformer EP-312SG with RoHS Description: RoHS Compliant Surface Mount Device Operating temperature range: -40 to +125 Turns Ratio: 1:0.083:0.208 (3%) Inductance: 253...