| Sign In | Join Free | My burrillandco.com |
|
... 2 RDC 650 mΩ max. DC Resistance 3 RDC 650 mΩ max. Turns ratio n 3:1:1 Voltage-μSecond B = 280 mT ∫Udt 140 μVs typ. Interwinding capacitance 100 kHz/ 100 mV CWW ......
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 750 μH min. Leakage inductance 100 kHz/ 100 mV LS 4.0 μH max. DC Resistance 1 RDC 1100 mΩ max. DC R...
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 260 μH min. Leakage inductance 100 kHz/ 100 mV LS 1.7 μH max. DC Resistance 1 RDC 600 mΩ max. DC Re...
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 330 μH min. Leakage inductance 100 kHz/ 100 mV LS 1.9 μH max. DC Resistance 1 RDC 620 mΩ max. DC Re...
...Transformer For Pulse Application D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 350 μH min. Leakage inductance 100 kHz/ 100 mV LS 2.3 μH max. DC Resistance 1...
24V 12V Step Down Ferrite Core Small Signal Transformer Properties Test conditions Value Unit Tol. Inductance base 10 kHz/ 100 mV Lbase 8.5 μH ±20% Turns ratio N1:N2:N3:N4:N5:N6 n 1:1:1:1:1:1 Rated Current base...
Laminated Core Switch Mode Transformer Used for LED Light Properties Test conditions Value Unit Tol. Inductance Base 100 kHz/ 100 mV LBASE 27.4 μH ±20% Turns Ratio n 1:1:1:1:1:1 Voltage-μSecond Base ∫Udt Base 4...
...Transformer / Choke for Texas Instruments Description: Size:14.75x8.3x4.2mm Pin:3+3pins Material: Copper wire and core Color:Black D.C. Resistance: 0.170 ohms Inductance:350uH Dielectric: 2500VAC Turns Ratio...
...Transformer For 12V Halogen Lamp ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 1-3 @20°C 0.330 ohms max D.C. RESISTANCE 6-4 @20°C 0.750 ohms max INDU...
...Transformer ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C RESISTANCE 1-3 @20°C 0.436 ohms max D.C RESISTANCE 6-4 @20°C 0.581 ohms max INDUCTANCE 1-3 100KHz, 100m...
...(6+7+8+9+10),100KHz,10mVAC,Ls 160nH typ,240nH max DIELECTRIC 2-10 3125vac,1 second 2500VAC, 1 minute TURNS RATIO (9-7):...
...(6+7+8+9+10),100KHz,10mVAC,Ls 160nH typ,240nH max DIELECTRIC 2-10 3125vac,1 second 2500VAC, 1 minute TURNS RATIO (2-4):...
...(6+7+8+9+10),100KHz,10mVAC,Ls 160nH typ,240nH max DIELECTRIC 2-10 3125vac,1 second 2500VAC, 1 minute TURNS RATIO (9...
...Transformer ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 2-4 @20°C 0.124 ohms max D.C. RESISTANCE 9-7 @20°C 0.103 ohms max D.C. RESISTANCE 10-6 @20°...
...Transformer For Industrial Automation ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C RESISTANCE 1-3 @20°C 0.100 ohms max D.C RESISTANCE 6-4 @20°C 0.150 ohms max I...
...°C 0.125 ohms max INDUCTANCE 1-3 100KHz, 100mVAC,Ls 72uH min DIELECTRIC 1-6 3125VAC, 1 second 2500VAC,1 minute TURNS RATIO (6-4):(1-3) 1.7:1,±2% GENERAL SPECIFICATIONS: OPERATING TEMPERATURE RANGE: -40°C TO ...
...Transformer ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 1-3 @20°C 0.160 ohms max D.C. RESISTANCE 6-4 @20°C 0.110 ohms max INDUCTANCE 1-3 100KHz,10m...
...°C 0.400 ohms max INDUCTANCE 1-3 100KHz,10mVAC,Ls 370uH min. DIELECTRIC 1-6 6250vac,1 second 5000Vrms, 1 minute TURNS RATIO (6-4):(1-3) 2:1±2% GENERAL SPECIFICATIONS: OPERATING TEMPERATURE RANGE: -40°C TO +8...
...(6+7+8+9+10),100KHz,10mVAC,Ls 160nH typ,240nH max DIELECTRIC 2-10 3125vac,1 second 2500VAC, 1 minute TURNS RATIO (9-7):(2...
Power Over Ethernet Transformer For Electrical Equipment D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 40 μH ±10% Turns ratio LS 5 : 1 : 1.25 ±3% Saturation cur...