200A Isolation Current Transformer For I-P Close Link Meter Testing Ratio 1:1 KE632x-200 Isolation Current Transformer KE632 series Isolation Current Transformer is used on multi-position test benches for testi...
... phase to three phase. With wide current range, it is perfect for the test of I-P close link meter. Features: High accuracy through active electronic error compensation. Direct perforated installation Wide c...
...P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency altern...
Transformer Demagnetizer| XHXC110 The XHXC110 transformer demagnetizer is a dedicated device for eliminating residual magnetism hazards after DC resistance testing of large power transformers and instrument tra...
Transformer Demagnetizer| XHXC105 The XHXC105 transformer demagnetizer is a dedicated device for eliminating residual magnetism hazards after DC resistance testing of large power transformers and instrument tra...
Electrical Specifications of 7490240140 SMT Transformer: Parameter Test conditions Value Unit Tol. Turn Ratio(±2%) 1∶1 Inductance 100 kHz / 100 mV @ 8 mA 350 µH min. Insulation Test Voltage 1 min. 4000 V (RMS) ...
...Transformer CT PT Analyzer Product introduction the Transformer CT PT Analyzer can obtain the excitation characteristics of the current and voltage transformers, excitation parameters. The maximum inflection...
...℃ 0.17 ohms max Inductance 1-2 10kHz,100mVAC, Ls 62uH min Dielectric 1-4 3750VAC, 1 second 3000VAC, 1minute Turns ratio (4-3) : (1:2) 1:1, ±1% Product photo: Schematic diagram: How to place the order to us: ...
... and instrument transformers after DC resistance testing. Residual magnetism, caused by the inherent hysteresis of ferromagnetic materials during voltage ratio and DC resistance measurements, can lead to tra...
... 1 @ 20°C RDC 6 mΩ max. DC Resistance 2 @ 20°C RDC 6.50 Ω max. Turns ratio W1 : W2 n 1 : 125 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 68 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V ...
... 6 mΩ max. DC Resistance 2 @ 20°C RDC 1.75 Ω max. Turns ratio W1 : W2 n 1 : 60 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 30 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E General...
... 6 mΩ max. DC Resistance 2 @ 20°C RDC 0.90 Ω max. Turns ratio W1 : W2 n 1 : 40 ±3% Voltage-μSecond Uref*DCmax/f ∫Udt 20 μVs max. Rated voltage UR 80 V Insulation test voltage 3 mA/1 s UT 500 V (AC) E General...
... Ω max. DC Resistance 3 @ 20°C RDC3 4.0 mΩ max. Leakage inductance 100 kHz/ 100 mV LS 1.4 μH max. Insulation test voltage N1,2 => N3,4,5...
...Transformer For Triggering Power Thyristors D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 650 μH min. Leakage inductance 100 kHz/ 100 mV LS 2.9 μH max. DC Re...
...Transformer For power driver D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 750 μH min. Leakage inductance 100 kHz/ 100 mV LS 4.0 μH max. DC Resistance 1 RDC ...
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 370 μH min. Leakage inductance 100 kHz/ 100 mV LS 1.8 μH max. DC Resistance 1 RDC 520 mΩ max. DC Re...
...Transformer For LED D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 112 μH ±10% Turns ratio LS 3 : 1 : 0.5 ±3% Saturation current |ΔL/L| < 20% Isat 3.2 A typ. ...
...Transformer For Mobile Charger D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 150 μH ±10% Rated current ΔT = 40 K IR 1.5 A max. Saturation current |ΔL/L| < 20...
...insulating oil and others insulating liquid. It is composed by insulating loss oil cup, temperature controller, temperature sensor, insulating loss testing bridge, AC testing power source, standard capacitor...
..., ac cascade and ac/dc cascade, it equips with operation unit. The product conforms to the requirement of the standard of "JB-357084 test transformer". Features 1.Small and...