| Sign In | Join Free | My burrillandco.com |
|
6+6pins Switch Mode Transformer for switching power Properties Test conditions Value Unit Tol. Inductance base 10 kHz/ 100 mV Lbase 14.7 μH ±20% Turns ratio N1:N2:N3:N4:N5:N6 n 1:1:1:1:1:1 Rated Current base ΔT...
Flyback Converter / inverter Power Over Ethernet Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 128 μH ±25% Turns ratio N 3.2:1:1:2.8 ±3% Saturation ...
EE EFD ER EPC PQ type electrical power Small Signal Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 100 mV L 100 μH ±25% Turns ratio n 6:1:1:3 ±3% Saturation ...
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 1080 μH min. Leakage inductance 100 kHz/ 100 mV LS 5.0 μH max. DC Resistance 1 RDC 1300 mΩ max. DC ...
Ferrite Magnet Electronic Switch Mode Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance base 10 kHz/ 100 mV Lbase 10.9 μH ±20% Turns ratio N1:N2:N3:N4:N5:N6 n 1:1:1:1:1:...
SMD 6+6 Pins Horizontal Switch Mode Transformer Electrical Properties: Properties Test conditions Value Unit Tol. Inductance Base 100 kHz/ 100 mV LBASE 14.7 μH ±20% Turns Ratio n 1:1:1:1:1:1 Voltage-μSecond Bas...
...Transformer ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C RESISTANCE 1-3 @20°C 0.33 ohms max D.C RESISTANCE 6-4 @20°C 0.33 ohms max INDUCTANCE 1-3 100KHz, 100mVA...
...Transformers SMPS Flyback Transformer 760390013 ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C RESISTANCE 1-3 @20°C 0.419 ohms max D.C RESISTANCE 6-4 @20°C 0.335 ...
...°C 0.481 ohms max INDUCTANCE 1-3 100KHz, 100mVAC,Ls 340uH min DIELECTRIC 1-6 6250Vrms, 1 second 5000Vrms,1 minute TURNS RATIO (6-4):(1-3) 1.7:1,±2% GENERAL SPECIFICATIONS: OPERATING TEMPERATURE RANGE: -40°C ...
...(6+7+8+9+10),100KHz,10mVAC,Ls 160nH typ,24nH max DIELECTRIC 2-10 3125vac,1 second 2500VAC, 1 minute TURNS RATIO (9-7):...
...Transformer For Self Defense Equipment ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C RESISTANCE 1-3 @20°C 0.100 ohms max D.C RESISTANCE 6-4 @20°C 0.080 ohms max ...
...,Ls 110uH min. CAPACTANCE 1-6 100KHz,100mVAC,Cs 18pF max DIELECTRIC 1-6 6250vac,1 second 5000Vrms, 1 minute TURNS RATIO (6-4):(1-3) 1...
6+6 Pin Power over Ethernet Small Signal Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 100 kHz/ 100 mV L 400V μH ±10% Turns ratio n 1:0.25:0.08:0.08:0.08 ±3% Saturat...
...Transformer For Medical Equipment ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C RESISTANCE 1-3 @20°C 0.35 ohms max D.C RESISTANCE 6-4 @20°C 0.57 ohms max INDUCTA...
Pulse Encapsulated Power Over Ethernet Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 21 μH ±10% Turns ratio N 6:9:9:4 ±3% Saturation current |ΔL/L| ...
EP-816SG SMPS Flyback Transformer Use For Small Electronic Equipment D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance Base 100 kHz/ 100 mV LBASE 46.3 μH ±10% Turns Ratio N1:N2:N3:N...
... is up to 18A. Frequency range is 1kHz to 1MHz. Five standard turns ratio options are available: 1:50, 1:100, 1:150, 1:200, and 1:300, suitable for different detection accuracy requirements. Withstand voltag...
... instrument developed on the basis of traditional transformer VA characteristic, ratio and polarity testers that rely on voltage regulators, boosters and current boosters. Adopting a high-performance DSP and...
Product Description: This Transformer Oleic Acid Value Tester is designed for testing transformer oil quality with a measuring range from 0.001~1.000mgKOH/g. It has a LCD display and offers an accuracy of 0.1. ...
Two Phase Isolation Current Transformer for I-P close link meter ratio 1:1 KE6322 Isolation current transformer KE6322 is a two phase 1:1 current transformer, which mainly used to test I-P close link meter. It ...