... Standard Gate Charge 24nC Td (on/off) @ 25°C 12ns/91ns Test Condition 400V, 10A, 30 Ohm, 15V Reverse Recovery Time (trr) 263ns Operating Temperature -55°C ~ 150°C...
...IGBT Type PT Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 65A Current - Collector Pulsed (Icm) 109A Vce(on) (Max) @ Vge, Ic 2.5V @ 15V, 20A Power - Max 290W Switching Energ...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 14A Current - Collector Pulsed (Icm) 28A Vce(on) (Max) @ Vge, Ic 1.95V @ 15V, 7A Power - Max 24W Sw...
... Type Standard Gate Charge 270nC Td (on/off) @ 25°C 32ns/123ns Test Condition 600V, 100A, 1 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~...
... Standard Gate Charge 22nC Td (on/off) @ 25°C 11ns/115ns Test Condition 400V, 4A, 48 Ohm, 15V Reverse Recovery Time (trr) 40ns Operating Temperature -40°C ~...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 3000V Current - Collector (Ic) (Max) 34A Current - Collector Pulsed (Icm) 150A Vce(on) (Max) @ Vge, Ic 3.2V @ 15V, 20A Power - Max 150W Switching Energ...
...IGBT Type Trench Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 140A Current - Collector Pulsed (Icm) 225A Vce(on) (Max) @ Vge, Ic 2.1V @ 15V, 75A Power - Max 454W Switching ...
... Standard Gate Charge 24nC Td (on/off) @ 25°C 12ns/91ns Test Condition 400V, 10A, 30 Ohm, 15V Reverse Recovery Time (trr) 262ns Operating Temperature -55°C ~ 175°C...
...IGBT Type Trench Field Stop Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 229A Current - Collector Pulsed (Icm) 300A Vce(on) (Max) @ Vge, Ic 1.85V @ 15V, 100A Power - Max 62...
... Standard Gate Charge 24nC Td (on/off) @ 25°C 12ns/91ns Test Condition 400V, 10A, 30 Ohm, 15V Reverse Recovery Time (trr) 262ns Operating Temperature -55°C ~ 150°C...
... Standard Gate Charge 24nC Td (on/off) @ 25°C 12ns/91ns Test Condition 400V, 10A, 30 Ohm, 15V Reverse Recovery Time (trr) 262ns Operating Temperature -55°C ~ 175°C...
... Standard Gate Charge 32nC Td (on/off) @ 25°C 15ns/94ns Test Condition 400V, 15A, 20 Ohm, 15V Reverse Recovery Time (trr) 317ns Operating Temperature -55°C ~ 150°C...
... Standard Gate Charge 22nC Td (on/off) @ 25°C 10ns/116ns Test Condition 400V, 4A, 48 Ohm, 15V Reverse Recovery Time (trr) 41ns Operating Temperature -40°C ~...
... Standard Gate Charge 27nC Td (on/off) @ 25°C 24ns/190ns Test Condition 480V, 9A, 50 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C (TJ)...
... Standard Gate Charge 26nC Td (on/off) @ 25°C 22ns/110ns Test Condition 480V, 6.5A, 50 Ohm, 15V Reverse Recovery Time (trr) - Operating Temperature -55°C ~ 150°C...
... Standard Gate Charge 27nC Td (on/off) @ 25°C 43ns/240ns Test Condition 480V, 9A, 50 Ohm, 15V Reverse Recovery Time (trr) 37ns Operating Temperature -55°C ~ 150°C...
...IGBT Type NPT Voltage - Collector Emitter Breakdown (Max) 600V Current - Collector (Ic) (Max) 11A Current - Collector Pulsed (Icm) 22A Vce(on) (Max) @ Vge, Ic 2.5V @ 15V, 4A Power - Max 63W Switching Energy ...
... Standard Gate Charge 23nC Td (on/off) @ 25°C 17ns/160ns Test Condition 480V, 7.8A, 75 Ohm, 15V Reverse Recovery Time (trr) 28ns Operating Temperature -55°C ~...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 650V Current - Collector (Ic) (Max) 30A Current - Collector Pulsed (Icm) 45A Vce(on) (Max) @ Vge, Ic 2.15V @ 15V, 15A Power - Max 214W Switching Energy...
...IGBT Type - Voltage - Collector Emitter Breakdown (Max) 430V Current - Collector (Ic) (Max) 20A Current - Collector Pulsed (Icm) - Vce(on) (Max) @ Vge, Ic 1.75V @ 5V, 14A Power - Max 125W Switching Energy - ...