| Sign In | Join Free | My burrillandco.com |
|
...wall mesh, stainless steel rope mesh for plant climbing 1. Brief introduction: X-tend green wall mesh, stainless steel rope mesh for plant climbing is also called Rope mesh, the material is producing by high...
...Wall Charger Fast Charger Mobile Cable Charger Quick Details 1. New GaN technique, PD 45W, fast charging function 2. Small size US wall charger, high power 3. High quality and better overlooking, good shape ...
...wall mesh, stainless steel rope mesh for plant climbing 1. Brief introduction: X-tend green wall mesh, stainless steel rope mesh for plant climbing is also called Rope mesh, the material is producing by high...
... Thickness 0.90mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance Capacitance 54 ±3 pF/m Impedance 75 ± 3 Ω Return loss between 5 and 1000MHz: > 22dB ......
... Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance 87.5Ω/KM at 20℃ Capacitance 67 ±3 pF/m Impedance 75 ± 3 Ω Return ......
... of insulation 0.075"/1.90mm PVC-CM (Red,Black) Jacket 9.5mm PVC-CM Application For Use in Longer CCTV Run Lengths Electrical Characteristics:...
...Cable NO.7102032 Construction Parameters: Inner Conductor 0.032"/0.81mm/20AWG Bare Copper Dielectric 0.144"/3.66±0.05mm Foamed Polyethylene Shield 0.12mm ALMG-Braid(95%) Jacket 0.236"/6.00±0.1mm PVC/PE/LSZH ...
...Cable NO.7102039 Construction Parameters: Inner Conductor 0.58mm Bare Copper Dielectric 0.144"/3.66±0.05mm Solid Polyethylene Shield 0.12mm CCA-Braid(95%) Jacket 0.236"/6.00±0.1mm PVC/PE/LSZH Power Wire Cond...
... braid wire 55% coverage Jacket 6.7±0.15mm PVC Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be < ...
... braid wire 55% coverage Jacket 6.7±0.15mm LSZH Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <...
...Cable NO.7100443 Construction Parameters: Inner Conductor 0.04"/1.00mm/18AWG BC Dielectric 4.6mm FPE Shield 1 4.75mm overlapped copper foil Shield 2 16*4*0.12mm bare copper braid wire 55% coverage Jacket 6.7...
...Cable NO.7100444 Construction Parameters: Inner Conductor 0.04"/1.00mm/18AWG BC Dielectric 4.6mm FPE Shield 1 4.75mm overlapped copper foil Shield 2 16*4*0.12mm bare copper braid wire 55% coverage Jacket 6.7...
... wire Diameter of insulation 1.6mmPVC (Red,Black) Jacket 6.6×8.2mm PVC/PE/LSZH Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The...
...Cable NO.7100445 Construction Parameters: Inner Conductor 0.05"/1.25mm/16AWG BC Dielectric 5.5mm 5 cell air spaced PE Shield 1 4.75mm overlapped copper foil Shield 2 16*6*0.12mm bare copper braid wire 60% co...
... braid wire 60% coverage Jacket 7.8±0.20mm LSZH Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <...
...Cable NO.7100447 Construction Parameters: Inner Conductor 0.065"/1.67mm/14AWG BC Dielectric 7.28mm 5 cell air spaced PE Shield 1 overlapped copper foil Shield 2 16*6*0.12mm bare copper braid wire 55% coverag...
...Cable NO.7100448 Construction Parameters: Inner Conductor 0.065"/1.67mm/14AWG BC Dielectric 7.28mm 5 cell air spaced PE Shield 1 overlapped copper foil Shield 2 16*6*0.12mm bare copper braid wire 55% coverag...
...Cable NO.7100449 Construction Parameters: Inner Conductor 0.091"/2.33mm/11AWG BC Dielectric 10.06mm 5 cell air spaced PE Shield 1 overlapped copper foil Shield 2 16*6*0.15mm bare copper braid wire 55% covera...
...Cable NO.7100450 Construction Parameters: Inner Conductor 0.091"/2.33mm/11AWG BC Dielectric 10.06mm 5 cell air spaced PE Shield 1 overlapped copper foil Shield 2 16*6*0.15mm bare copper braid wire 55% covera...
...(10*0.12mmCCA ) Power wire Diameter of insulation 0.91HDPE(Red,Black) Jacket 3.0mmPVC Application For Use in Longer CCTV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ sha...