...Cable NO.7101202 Construction Parameters: Inner Conductor 19×0.287mm Copper Dielectric 3.94mm Foamed PE Shield 1 95% Coverage TC Jacket 6.15mm PVC Jacket Thickness Application Electrical Characteristics: Cap...
...Cable NO.7101203 Construction Parameters: Inner Conductor 19×0.287mm Copper Dielectric 3.94mm Foamed PE Shield 1 95% Coverage TCCA Jacket 6.15mm PVC Jacket Thickness Application Electrical Characteristics: C...
...Cable NO.7101207 Construction Parameters: Inner Conductor 19×0.18mm Copper Dielectric 2.95mm Solid PE Shield 1 Nom. 3.50mm Copper Jacket 4.95mm PVC Jacket Thickness Application Electrical Characteristics: Ca...
...Cable NO.7101209 Construction Parameters: Inner Conductor 7×0.17mm Bare Copper Dielectric 1.52mm Solid PE Shield 1 Nom. 1.90mm Tinned Copper Jacket 2.79mm PVC Jacket Thickness Application Electrical Characte...
...Cable NO.7101210 Construction Parameters: Inner Conductor 7×0.17mm CCS Dielectric 1.52mm Solid PE Shield 1 Nom. 1.90mm Tinned Copper Jacket 2.79mm PVC Jacket Thickness Application Electrical Characteristics:...
...Cable NO.7100386 Construction Parameters: Inner Conductor 0.68 mm Cu Dielectric 4.30mm FPE Shield 64/ 0.15mm CCAM Jacket 6.7mm PE black Jacket Thickness Application For Use in Longer CATV Run Lengths Electri...
KX8+21.00 PVC - Figure 8(NO.7102073) Construction Parameters: Inner Conductor: 7 0.40mm Bare Copper Insulation: 7.24mm SPE Shield: 168 x 0.16mm CCA (95%) Jacket: 10.00mm PVC Green Power Wire Conductor: 2 x 3...
...Cable QR540 75 Ohm CATV Coaxial Cable NO.7100416 Construction Parameters: Inner Conductor 9AWG 3.15mm CCA Dielectric 13.03mm Foamed PE Outer Conductor 13.72mm Welding Aluminum Tube Jacket 15.49mm PE Black Ja...
... Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <1.90 Ω/km Capacitance 50 ± 3 pF/m Impedance 75 ± 2 Ω Return loss between 5 and 1000MHz:...
... Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <3.34 Ω/km Capacitance 50 ± 3 pF/m Impedance 75 ± 2 Ω...
... Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <1.90 Ω/km Capacitance 50 ± 3 pF/m Impedance 75 ± 2 Ω...
... Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <1.33 Ω/km Capacitance 50 ± 3 pF/m Impedance 75 ± 2 Ω...
...Cable 75 Ohm CATV coaxial Cable NO.7100501 Construction Parameters: Inner Conductor 1.00mm Copper Dielectric 4.75mm Foamed PE Shield 1 Aluminum PET Shield 2 CuSn braid wire 38% coverage Jacket 6.60±0.10mm PV...
... Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be < 34.3 Ω/km Capacitance 54 ±3 pF/m Impedance 75 ± 3 Ω Return loss between 5 and 1000MHz:...
...Cable 75 Ohm CATV coaxial Cable NO.7100503 Construction Parameters: Inner Conductor 1.00mm Copper Dielectric 4.30mm±0.10 Foamed PE Shield 1 Aluminum PET Shield 2 CuSn braid wire 40% coverage Jacket 6.60±0.10...
...Cable 75 Ohm CATV coaxial Cable NO.7100504 Construction Parameters: Inner Conductor 1.13mm±0.02mm Copper Dielectric 4.8mm±0.10 Foamed PE Shield 1 Aluminum PET Shield 2 CuSn braid wire 45% coverage Shield 3 6...
... Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be < 17.5 Ω/km Capacitance 54 ±3 pF/m Impedance 75 ± 3 Ω Return loss between 5 and 1000MHz:...
... Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be < 17.5 Ω/km Capacitance 54 ±3 pF/m Impedance 75 ± 3 Ω Return loss between 5 and...
...Cable NO.7100261 Construction Parameters: Inner Conductor 0.064"/1.63mm/14AWG BC Dielectric 0.144"/7.11mm Foamed Polyethylene Shield Bare Copper(95%) Jacket 0.4"±0.006"/10.3mm±0.15mm PE Application For Use i...
...Cable NO.7100905 Construction Parameters: Inner Conductor 7×0.18mmBC Dielectric 3.1mm SPE Shield 0.14mm×6×25 BC Braid(L=26) Jacket 5.4±0.5mmPVC Jacket Thickness 0.08mm Application For Use in Longer CCTV Run ...