| Sign In | Join Free | My burrillandco.com |
|
... with 1.5mm thickness, and painted, so that the barrier can be used in door and outdoor. Quick Detail: Name: Boom barrier gate Application: Ticket dispenser Speed:3/6 second Feature:...
Security System Automatic Road Barrier Gate Description: 1) Fastest running speed can be 0.4 seconds (model WJCB02E, 0.4~0.9s adjustable) 2) Barrier gate life-span: >5,000,000 times 3) Suit application: indoor ...
... (T90) £30 seconds Linearity Long-term stability < 2% signal value/month Storage time: 6 months (in the box) Storage temperature 0 ℃ to 20 ℃ Service life in air for 2 years Specifications: Operating tempe...
... applications for detection of Phosphine (PH3) in industrial,environmental and life safety protection fileds. Datasheet: Resolution 0.1 ppm Response time T90 ≤60 seconds Operating temperature -20℃ to 50℃ Wor...
...o 100PPM Datasheet: Resolution 1 ppm Response time (T90) ≤30 seconds Working temperature -20℃ to 50℃ Working humidity 15 ~ 90%RH (no condensation) Working pressure 90 to 110 kPa Bias 0 mV Storage temperature...
... element chip (HNF-H2-CS) and a compensation element chip (HNF-H2-CR). It has the characteristics of fast response time (<1 second), low power consumption, long life, large range, high measurement accuracy, high...
..., making it easy to carry and use in various applications. This Oxygen Gas Detector is built to last, with a working life of over 2 years, ensuring long-term performance and durability. Its response time t90...
...: -20℃ ~ 50℃ Pressure range: up to 10 atmospheres; Humidity range: 15% ~ 90%, no condensation; Response time t90:50 seconds (at 20℃) Long-term output drift: < 10% per year Repeatability: <...
... Product Description: Hydrogen sulfide sensor H2S-AH is mainly characterized by two years of life, large current output; Typically used in hydrogen sulfide portable instrument. Second, hydrogen sulfide senso...
... sensor H2S-BH: two years of life, large current output, etc., typically used in stationary hydrogen sulfide transmitters. Second, hydrogen sulfide gas sensor H2S-BH main parameters Measuring range: 50ppm Se...
... dioxide sensor NO2-A1 has the characteristics of no filter screen, two years of life, suitable for industrial environment nitrogen dioxide portable instrument, etc., typical application in nitrogen dioxide ...
...KE-25 characteristics: (1) Long life (2) Not affected by CO2, CO, H2S, NOx, H2 (3) Low cost (4) Work at room temperature (5) Signal output is stable (6) No external power supply is required (7) No heating is...
..., H2 (3) Low cost (4) Work at room temperature (5) Signal output is stable (6) No external power supply is required (7) No heating is required Second, oxygen sensor KE-25F3 performance: (1) Detection range 0...
...KE-50 characteristics: (1) Long life (2) Not affected by CO2, CO, H2S, NOx, H2 (3) Low cost (4) Work at room temperature (5) Signal output is stable (6) No external power supply is required (7) No heating is...
... (resistance ratio) : 0.55-0.65 3) Heater voltage: 5V±0.2V(DC/AC) 4) Circuit voltage: 24V(AC/DC) Second, combustible gas sensor TGS816 features: High sensitivity to flammable gases such as alkanes; Long life...
... ± 0.1 Circuit voltage: 24V(DC/AC) Heater voltage: 5V±0.2V(AC/DC) Second, the main features of the alcohol sensor TGS822: Long life, low power consumption; Later circuit is simple; High sensitivity to alcoho...
... ratio) : 0.50 ~ 0.65 Heater voltage: 5.0±0.2V DC/AC Circuit voltage: 5.0±0.2V DC/AC Second, combustible gas sensor TGS2612 Product features: Low power consumption; LPG and natural gas can be measured simult...
... Operating Life:Two years in air Output Signal:0.003 ± 0.001 µA/ppm Resolution:10ppm Temperature Range:-20°C to +50°C Pressure Range:Atmospheric ± 10% Pressure Coefficient:0.006 % signal/mBar T90 Response Ti...
...Life Two years in air Output Signal 0.37 ± 0.07 µA/ppm Resolution 0.5ppm Temperature Range -20° to +50°C Pressure Range Atmospheric ± 10% Pressure Coefficient 0.015 % signal/mBar T90 Response Time £20 second...
... Life Two years in air Output Signal 0.37 ± 0.07 µA/ppm Resolution 0.5ppm Temperature Range -20° to +50°C Pressure Range Atmospheric ± 10% Pressure Coefficient 0.015 % signal/mBar T90 Response Time £20 secon...