| Sign In | Join Free | My burrillandco.com |
|
4R-PID Photoionization PID Gas Sensor VOC High Performance 4R-PID is a high performance photoionization PID sensor. The sensor has the characteristics of high sensitivity, wide range and broad spectrum, which c...
ME3-H2S Hydrogen Sulphide Gas Sensor Constant Potential Electrolytic Type 500ppm ME3-H2S sensor is a constant potential electrolytic H2S sensor. H2S and O2 undergo corresponding redox reactions at the working e...
ME3-HCN Electrochemical Hydrogen Cyanide HCN Gas Sensor 150ppm Potential Electrolytic ME3-HCN hydrogen cyanide sensor is a constant-potential electrolytic sensor. Hydrogen cyanide reacts with oxygen on the work...
ME4-H2S Hydrogen Sulfide Gas Sensor H2S Industry And Environmental Protection Field ME4-H2S sensor is a constant potential electrolytic H2S sensor. H2S and O2 undergo corresponding redox reactions at the workin...
ME4-NO2 Nitrogen Dioxide Gas Sensor Industry And Environmental Protection 20PPM ME4-NO2 sensor is a constant potential electrolytic NO2 sensor. The corresponding redox reaction between NO2 and O2 occurs on the ...
ME4-NO2-E4 Outdoor Nitrogen dioxide Gas Sensor 50ppm Constant Potential Electrolytic Type ME4-NO2-E4 sensor is a constant potential electrolytic NO2 sensor. The corresponding redox reaction between NO2 and O2 o...
PID-AH5 Photoion VOC Detector Small Range Fast Response Time PID gas sensor/VOC detection sensor PID-AH5 (small range) product introduction: PHOTO IONIZATION DETECTORS can measure VOCs (volatile organic compoun...
...Gas Sensor Ultra Low Power 80kPa Features: Warranty period or any extended warranties would be confirmed with the order confirmation. The warranty is invalidated if the sensor is used under conditions or spe...
... Monoxide CO Gas Sensors Electrochemical 2000PPM Range Specifications are more ideal when the sensor is used at 20°C, 50% rH and 1013 mBar.using manufacturer recommended circuitry. Performance characteristic...
...Gas Sensors 4 Electrode Electrochemical 3 Series None Filter EnviroceLs are designed for operation in a wide range of environments and harsh conditions. important that exposure to high concentrations of solv...
MH-Z1911A CO2 Gas Sensor NDIR Principle and 1 Minute Response Time Description MH-Z1911A infrared CO2 sensor is intelligent sensor with small size, using non-dispersive infrared (NDIR) principle to detect the c...
...Gas Sensors Detects Most Flammable Vapours and Gases The MP7227-DA pellistor is a low power, hazardous area safe,extremely robust and poison-resistant device in a certified flameproof enclosure. The MP7227-D...
... on a sample of about 16 sensors. The results are shown in the graph as a mean for the batch, and expressed as a percentage of the signal at 20°C. From a statistical viewpoint, for a sample of this size, the...
... concentration. It operates on the three - electrode electrochemical principle. This design not only enhances the stability of the sensor but also effectively reduces signal drift during long - term operatio...
... recommended circuitry. · Sensor performance is temperature dependant; please contact SGX for temperature performance other than 20°C. · Do not solder to the connector pins as this may damage the sensor and ...
Product Description: NH3-B1 electrochemical ammonia gas sensor for various ammonia detection applications Features: Ammonia sensor NH3-B1 Details: First, ammonia sensor NH3-B1 main parameters Overload: 200ppm Z...
...Gas Sensor For Sulfur Dioxide Portable Alarm Features: First, sulfur dioxide sensor SO2-AF main parameters Overload: 75ppm Response time: <35s Size: Φ20×16.5 Sulfur dioxide detection range: 0-50ppm Sensitivity: 300-550nA /ppm Resolution: < 0.1ppm Linearity: 0~10ppm is linear, the full range linearity error is < ±0.3ppm 2. Typical application of sulfur dioxide sensor......
3LEL 3R CLL-6112-300 0 – 100%LEL Combustible Gas Sensor 2.3V LEL Sensor Operation Conditions: Temperature Range -20oC to 50oC Operating Humidity 15-90%RH non-condensing Operating Voltage 2.......
...Gas Sensor For Hydrogen Alarm Features: First, hydrogen (H2) sensor TGS821 main parameters: Hydrogen detection range: 10-5000ppm Sensitivity (resistance ratio) : 0.60-1.20 Heater voltage: 5V±0.2V(AC/DC) Circ...
... and general Oxygen monitors. Stabilisation time Allow at least 15 minutes to stabilise in instrument before calibration. Cleaning and Sterilisation In case of contamination the sensor may be cleaned with...