| Sign In | Join Free | My burrillandco.com |
|
... Three Phase Electric Meter Test Bench 1) Standard Meter accuracy: 0.05%, 0.02% (optional) 2) Meter Error test, start current test, black mark catch, creep test, warm up test, dial test, influence quantities...
... Three Phase Electric Meter Test Bench 1) Standard Meter accuracy: 0.05%, 0.02% (optional) 2) Meter Error test, start current test, black mark catch, creep test, warm up test, dial test, influence quantities...
... Stability 0.05% or better Output Power ≥ 30VA/position (total power depends on meter positions) Current output Adjusting Range 3* (1mA~ 120A), can be up to 200A (optional) Adjustment Resolution 0.01% Output...
... Stability 0.05% or better Output Power ≥ 30VA/position (total power depends on meter positions) Current output Adjusting Range 3* (1mA~ 120A), can be up to 200A (optional) Adjustment Resolution 0.01% Output...
...Phase Electric Meter Test Bench Major Application and Functions: 1) Touch screen operation for control source panel 2) With standard meter together show all necessary parameters in one screen 3) Majorly used...
...Phase Electric Meter Test Bench Major Application and Functions: 1) Touch screen operation for control source panel 2) With standard meter together show all necessary parameters in one screen 3) Majorly used...
...Phase Energy Meter Testing Equipment Accuracy : 0.05 , Used for the test of three phase CT/PT meter with a accuracy class below 0.2, and can test single phase meter if adding an isolation voltage transformer...
...Phase:0-360 deg,Macro-adjustable phase:30°/shift, Micro-adjustable phase:0.1° Multiplex voltage separation PT is provided for each meter hanger carrier to ensure equal battery level of each meter station dur...
...Phase Energy Meter Test System for Versatile Applications Description GENY’s meter test systems adopt the most advanced electronic measurement technique, and modular concept, combining the different referenc...
...single phase energy meter calibration equipment KE8102 has multiple switchable channels for current output, used for testing 2 or 3 elements single phase mechanical and electric meter, Number of meter positi...
...Meter Testing Bench single phase accuracy 0.05 12 position 120A current KE8101 single phase meter testing bench KE8101 is used for the test of various single phase electric and mechanical meter, multi-functi...
...phase Meter Test Equipment Accuracy : 0.02 , Used for the test of standard meter and mounted meter with a accuracy class below 0.1, Number of meter position : 3-12 Features: High accuracy: 0.02% Integrated /...
...-function meter, PLC meter, multi-rate meter and prepayment meter. Features: • Integrated / Separated aluminum alloy structure, light and reliable, flexible choices • The number of meter positions can be cho...
...Single Phase Meter Test Equipment Suit for Lab Output voltage and current distortion not larger than 0.3%(if it is a linear load) The variation of pre-set output power within 180S will not exceed 0.02% compa...
...single phase meter test bench KE8104 has double current channels with ICT isolation, used for 2 element single phase mechanical and electric meter, Number of meter position: 3-48 Features: 1. Integrated / Se...
...Phase Electric Meter Testing Equipment Accuracy : 0.01 , Used for the test of standard meter and mounted meter with a accuracy class below 0.05, Number of meter position : 3-12 Features: · High accuracy: 0.0...
...Single Phase Meter Test Bench for Industrial Applications Product Description Meters under testing: 1P2W Testing mode active power, reactive power With MSVT, can test single phase meters with closed links be...
...Phase Stationary Meter Test Bench for Electric Energy Meter Testing Stationary Three Phase Meter Test Bench The YC1893D meter test system is a full-automatic test system for testing and calibration of both s...
Single Phase Meter Test Bench SYS12D series Meter position numbers optional: 3…….48 Error Test, Creep test, warm up test, start test, dial test, Standard Deviation Test,etc Harmonic test 2-21 times with analysi...
Single Phase Meter Test Bench SYS12D series Meter position numbers optional: 3…….48 Error Test, Creep test, warm up test, start test, dial test, Standard Deviation Test,etc Harmonic test 2-21 times with analysi...