| Sign In | Join Free | My burrillandco.com |
|
Compatible Nelllcor Adult soft Direct-Connect SpO2 Sensor #detail_decorate_root .magic-0{border-bottom-style:solid;border-bottom-color:#53647a;font-family:Roboto;font-size:24px;color:#53647a;font-style:normal;b...
Medical consumables Compatible reusable M-o adult soft spo2 sensor Compatibility: Manufacturer Model Bitmos sat 800, sat 801, sat 805, sat 816, satPuls CAS Med 511 Cardio Aid 200 Covidien > Nellcor N-3000, N-39...
...Probe for Uninsulated Live Part Conforms to UL507 Introduction UL accessiliby test probe for uninsulated live part is designed according to UL507 figure 9.1 (PA135A) and UL1278 figure 8.1 (PA130A). The handl...
...,UL1310 test finger probe This is the “UL” test finger, researched and designed by UL and required by most UL Standards. Palm simulator and restricted joint movement simulates human finger movement. Made of ...
1. Product Description : Ms neonate disposable SpO2 sensor,0.9m,DB7pin,medaplast, Adult spo2 sensor probe Ms adult disposable SpO2 sensor,0.45m,DB7pin,medaplast 2. Specifications: Technical Parameter Connector ...
IEC61032 Figure 16 Test Probe 41 Test Thorn Probe Product information: The test thorn probe is intended to verify the protection against access to glowing heating elements. It complies with IEC61032 figure 16 T...
... 4, Dam- board Length:100mm 5.M6 thread at the end of the probe(can be connected to the push-pull gauge) Packaging and Shipping 1. Aluminium box and carton box, careful and tight package, make sure the ......
Hazardous Moving Parts Probe UL1310 Fig.16.4 Product details: It conforms to standard requirement of UL1310 Fig 16.4(S3252). It is used for testing accessibility to hazardous moving parts such as access to fan ...
Rigid Finger Probe HT-I07 Standard:IEC61032 figure 7 device 11,IEC60884,IEC60598,IEC60335,IEC60065. Application:It is used to verify the protection of persons against access to hazardous parts, and to verify th...
Cone Probe Conform to the UL1278 Fig 10.1 UL Test Probe Product details: This probe conforms to the standard requirement of UL1278 Fig 10.1. The handle is made of nylon while the probe is made of stainless stee...
IEC60598-2-20 clause 20.11.2. Flat Probe Product information: This flat probe conforms to IEC60598-2-20 clause 20.11.2. It is used for testing the string lights which can not make all of the metal intertexture ...
...,250,Pepita 203, R204,204R,205, Pepita 205R Reliable Supplier 3m Direct Connect Reusable Adult finger clip Spo2 Sensor FOR Hellige Servomed 4.Generation SCP 844 http://www...
Biolight A5 digital SpO2 sensor with adult finger clip 1. Product Description : Biolight A5 digital SpO2 sensor with adult finger clip, Round 9pin 2. Specifications: Technical Parameter Connector type Round 9pi...
Biolight A5 digital SpO2 sensor with adult finger clip 1. Product Description : Biolight A5 digital SpO2 sensor with adult finger clip, Round 9pin 2. Specifications: Technical Parameter Connector type Round 9pi...
Biolight A5 digital SpO2 sensor with adult finger clip 1. Product Description : Biolight A5 digital SpO2 sensor with adult finger clip, Round 9pin 2. Specifications: Technical Parameter Connector type Round 9pi...
... technical parameters Emitting light waven length 660±5nm Absorbed light wavelength 905±5nm or 940±5nm SpO2 testing range 70%-100% SpO2 testing precision ±1% in 90%~100% ±2% in 80%~89% ±3% in 70%~79%...
HP Neonatal Wrap spo2 sensor Probe For M1025A/B M1205A M1350B M1722A/B V24E 1. Product Description : neonate SpO2 sensor for PH patient monitor 2. Specifications: Technical Parameter Connector type for machine ...
... 16.2, UL6500 Fig14, UL60065 Fig14 and UL60950 Fig NAF.1. Palm simulator and restricted joint movement simulates human finger movement. It is...
Test Bar Probe 43 Person Against Access to Hot or Glowing Parts Introduction: It is designed according to IEC61032 figure 17. This bar is intended to verify the protection of fixed and portable visibly glowing ...
IEC61032 Figure 8 Test probe 12 , 50mm Long Test Pin Probe Product information: This pin is intended to be used on appliances for verifying the inaccessibility of hazardous live parts or hazardous mechanical pa...