| Sign In | Join Free | My burrillandco.com |
|
...Controller Module Diesel Model Number DC50D MK3 Working voltage DC8V----36V Continuous Working condition -25-65℃ Storage condition -40-85℃ Overall dimension 210mm*160mm*50mm Panel cutout 186mm*142mm Weight 0...
...Controller Module Working voltage DC8V----36V Continuous Rotate speed sensor Frequency 200-10000Hz MAX Accumulating Time 99999.9Hours(Min Store time:6min) Working condition -20-65℃ Storage condition -40-85℃ ...
...Controller with LCD Display Working voltage DC8V----36V Continuous Working condition -25-65℃ Storage condition -40-85℃ Overall dimension 241mm*177mm*45mm Panel cutout 220mm*160mm Weight 0.9Kg Summary This se...
... -40-85℃ Overall dimension 241mm*177mm*45mm Panel cutout 220mm*160mm Weight 0.9Kg Summary This series controller is specialized for Diesel / Gasoline / Gas Genset Start, Stop, Parameters monitoring,...
... 30VAC-450VAC (ph-N) Overall dimension 106mm×86mm×45mm Panel cutout 78mm×66mm Weight: 0.25Kg Summary This Controller Series is specialized for small diesel, gasoline, gas generator sets’ start, stop, monitor...
...Control Panel High Temperature Alarm Operation Voltage DC8-36V Continuous Rotate speed sensor Frequency 1-10000Hz Working condition -25ºC ~+65 ºC Storage condition -40-85℃ MAX Accumulating Time 9999.9Hours(M...
... time:6min) Overall dimension 210mm*160mm*50mm Panel cutout 186mm*142mm Weight: 0.85Kg Summary This series controller is specialized for Diesel / Gasoline / Gas Genset Start, Stop, Parameters monitoring,...
...Controller Diesel Generator Monitoring Operation Voltage DC8-36V Continuous Rotate speed sensor Frequency 50-10000Hz Working condition -25-65℃ Storage condition -40-85℃ MAX Accumulating Time 9999.9Hours(Min ...
... -25-65℃ Overall dimension 142mm*105mm*45mm Panel cutout 116mm*90mm Weight: 0.6Kg summary This series of controllers is designed for the start, stop, parameter monitoring and fault monitoring of diesel, gaso...
... Model: AJ65BT-64AD Screw, 2 piece type terminal. Voltage / current output module. Number of channels: 2 channels. Number of stations: 2 stops. Station type: remote equipment station. High speed data transfe...
... Model: AJ65BT-64AD Screw, 2 piece type terminal. Voltage / current output module. Number of channels: 2 channels. Number of stations: 2 stops. Station type: remote equipment station. High speed data transfe...
... condition. 2, Stop.Stop the operation of the air compressor under the normal working state 3, Close stop/reset.This button should be shot in an emergency or not allowed to boot, and the AC power supply shou...
... condition. 2, Stop.Stop the operation of the air compressor under the normal working state 3, Close stop/reset.This button should be shot in an emergency or not allowed to boot, and the AC power supply shou...