| Sign In | Join Free | My burrillandco.com |
|
...Wide Selection of Two-circuit Double-break Limit Switch Can be installed in any of the four directions TZ5108-2 Limit Switch Features . Wide selection of two-circuit double-break limit switches . Rifid die-c...
..., loop current, no-load transformer, no-load cable charging current and closing short-circuit current. It equips with grounding load switch that can endure short-circuit current. It is mainly used for contro...
1. FLW34 Type Outdoor Pole-Mounted 12kv 24kv SF6 Load Break Switch FLW34 Type Outdoor Pole-Mounted 12kv 24kv SF6 Load Break Switch is suitable to the distribution network with rated voltage 12/24kV, rated curre...
1. FLW34-12/24 type outdoor pole-mounted HV AC SF6 insulation load break switch FLW34-12/24 type outdoor pole-mounted HV AC SF6 insulation load break switch is suitable to the distribution network with rated vo...
11kv 24kv 36kv Outdoor h.v. high voltage Load Break air disconnector disconnect Switch 1.Product Description Outdoor load break switch is used in outdoor 12/24/40.5kV three phase AC 50/60Hz power system, it com...
...,protective value and safe operation. The operation mechanism is a spring-accumulating and accelerating instant-release device,which makes instant making and breaking of the...
...Break Switch Isolator Switch Load Breaker Switch Disconnector Switch ( RDGL Series ) Product Description RDGL series isolation switch adopts modular design structure and glass fiber reinforced unsaturated po...
...switch Product Description Item Unit Data Power frequency with stand voltage KA 42 48 Rated current A 400 630 Thermal stable current(4s) A 12.5 20 Dynamic stable current(peak) KA 31.5 50 Rated breaking curre...
...Break Switch 3 Phase Isolator Load Break Disconnect Switch 800 A ( RDGL SERIES ) Product Description RDGL series isolation switch adopts modular design structure and glass fiber reinforced unsaturated polyes...
...ree poles + on and off neutral pole),and switches over 1000A are only suitable for electric isolation. 2. The product with observation window can be provided according to the demand to observe directly the o...
...break switch 630A 2000A FN5-12R(L) Model indoor AC HV load isolation switch and fuse combination apparatus is developed and designed based on international technology and national power supply requirement, i...
... Load Break Switch FZN21-12(R)D/T125-31.5 Series Indoor AC high voltage load switch- fuse combination units appliances for three-phase AC 10kV, 50Hz power system, or with the complete power distribution equi...
... Load Break Switch FZN21-12(R)D/T125-31.5 Series Indoor AC high voltage load switch- fuse combination units appliances for three-phase AC 10kV, 50Hz power system, or with the complete power distribution equi...
1. 24KV 3 phase 50Hz outdoor high voltage load break switch/Load interrupter switch 24kv load break switch is used to open medium voltage circuits up to 38 KV, connecting or disconnecting lines or cables, secti...
... Load Break Switch FZN21-12(R)D/T125-31.5 Series Indoor AC high voltage load switch- fuse combination units appliances for three-phase AC 10kV, 50Hz power system, or with the complete power distribution equi...