| Sign In | Join Free | My burrillandco.com |
|
...: 2.9 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Reset Delay Time: Programmable Supp...
...: 4.7 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Supply Voltage - Max: 10 V Minimum ...
... Voltage: 4.5 V Number of Inputs Monitored: 1 Input Output Type: Active High, CMOS Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Supply Voltage - Max: 10 V Minim...
...: 3 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: No Backup Reset Delay Time: 1.2 s Supply Voltag...
...: 1.7 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Supply Voltage - Max: 10 V Minimum ...
... Voltage: 3.3 V Number of Inputs Monitored: 1 Input Output Type: Active Low, CMOS Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Reset Delay Time: Programmable Su...
...: 2.5 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Reset Delay Time: Programmable Supp...
... Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: No Backup Reset Delay Time: 1.2 s Supply Voltage - M...
...: 1.5 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Reset Delay Time: Programmable Supp...
...: 3 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Supply Voltage - Max: 10 V Minimum Op...
...: 1.8 V Number of Inputs Monitored: 1 Input Output Type: Active High, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Supply Voltage - Max: 10 V Minimum...
... Voltage: 2.7 V Number of Inputs Monitored: 1 Input Output Type: Active Low, CMOS Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Reset Delay Time: Programmable Su...
...: 2.2 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Reset Delay Time: Programmable Supp...
...: 2.4 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Reset Delay Time: Programmable Supp...
... mV Number of Inputs Monitored: 1 Input Output Type: Active Low, CMOS Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Supply Voltage - Max: 10 V Minimum Operating ...
...: 4 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: No Backup Reset Delay Time: 460 ms Supply Vo...
...: 1.5 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: Backup Supply Voltage - Max: 10 V Minimum ...
...: 3.3 V Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: Manual Reset Watchdog Timers: No Watchdog Battery Backup Switching: No Backup Reset Delay Time: 300 ms Supply Vol...
...-5 Number of Inputs Monitored: 1 Input Output Type: Active Low, Open Drain Manual Reset: No Manual Reset Watchdog Timers: Watchdog Battery Backup Switching: No Backup Reset Delay Time: 210 ms Supply Voltage ...
... V Number of Inputs Monitored: 1 Input Output Type: Active Low, Push-Pull Manual Reset: No Manual Reset Watchdog Timers: Watchdog Battery Backup Switching: Backup Reset Delay Time: 200 ms Supply Voltage - Ma...