| Sign In | Join Free | My burrillandco.com |
|
...circuit breaker CKVB-12/GB 2.Technical Data Description Unit Parameter Rated voltage kV 12 Short-time withstand voltage kV 42 Lighting impulse withstand voltage kV 75 Rated frequency Hz 50 Rated current A 63...
...circuit breaker CKVB-12/GD 2. Technical Data Description Unit Parameter Rated voltage kV 12 Short-time withstand voltage kV 42 Lighting impulse withstand voltage kV 75 Rated frequency Hz 50 Rated current A 6...
...circuit breaker Kampa EZ9R33263 excellent Quality 2p 63Amp RCCB is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz,rated voltage 1 phase 230V and 3 phase 400V,rated current ...
...Circuit Breaker Kampa 30ma 63amp rccb RCCB is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz,rated voltage 1 phase 230V and 3 phase 400V,rated current up to 63A , When some...
...function of isolation switching and earth leakage protection of electrical circuits. They open a circuit automatically in the event of an earth fault between phase and earth and/or netural and earth. A wide ...
...Circuit Breaker Kampa NO7L4-63 63AMP High Quality rccb Specifications RCCB 1. High Quality. 2. W CE certificate 3. Very Comparative price 4. 2P, 4P 5,Breaking capacity(A): 6000A NO7L4-63 RCCB provide the fun...
...to 63A , When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value,the RCD can cut off the power within the time of 0.1s automatically protecting the equipment from ...
...Circuit Breaker 2p 16A 63A MCB 1.Introduction a.Application iC65N is mainly used in AC50/60Hz single pole230/240V or two,three,four pole 400/415V voltage for overload and short-circuit protection as well as ...
...circuit breaker 1p 3p 16a mcb 1.Introduction a.Application iC65N is mainly used in AC50/60Hz single pole230/240V or two,three,four pole 400/415V voltage for overload and short-circuit protection as well as f...
... the electric arc,and it enhance the safeness in the case of short -case of limited short-circuit.The brilliant characteristic of it's short-circuit current is superior to the related requirement of IEC60989...
...400V 4.5 Ka mini circuit breaker Construction: 1. Protection against both overload and short circuit 2. panel mounting 3. Easy mounting onto 35mm DINrail 4. Connection capacity:Rigid conductor up to 25mm2 5....
C45 Series 4.5ka 230 / 400V MCB Blue Handle Mini Circuit Breaker 1. Protection against both overload and short circuit 2. Rated impulse withstand voltage:6.2kv 3. High short-circuit breaking capacity(Icn):4.5kA...
... Standard 6KA MCB 1 Pole Red Copper Mini Circuit Breaker Construction and Feature: 1. Protection against both overload and short circuit 2. Electro-mechanical endurance:4000 3. High short-circuit capacity 4....
...-circuit capacity(Icn):10000A Rated service short-circuit capacity(Ics):7500A Rated frequency:50/60Hz Rated impulse withstand voltage:6.2kv Electro-mechanial endurance:......
...faulty line. 2. The handle cannot stay in such position when operatedmanually 3. High short-circuit capacity 10 KA for whole range and 15KA capacity for current rating up to 40A thanks to the powerful electr...
... capacity, reliable performance, high inflammable resistance and shock resistance for long service life. 3. It is within the circuit of AC 50/60Hz, rated voltage of single pole up to 240V, two, three or four...
1P / 2P / 3P / 4P MCB Red Copper 6Amp - 63Amp Mini Circuit Breaker Protection against both overload and short circuit High short-circuit capacity Easy mounting onto 35mm DIN rail Connection terminal:Pillar term...
6ka Breaking Capacity Red Copper MCB 230 / 400V Mini Circuit Breaker 1. Protection against both overload and short circuit 2. High short-circuit capacity 3. Easy mounting onto 35mm DIN rail 4. Panel mounting 5....
...63A Electrical Type MCB Mini Circuit Breaker Capable of switch electric circuit with load Capable of quickly releasing stored energy operation Adaptable to padlock device Contact position indication High sho...
...Circuit Breaker 1. Provide protection against earth fault/leakage current and function of isolation. 2. High short-circuit ccurrent withstand capacity. 3. Applicable to terminal and pin/fork type busbar conn...