| Sign In | Join Free | My burrillandco.com |
|
3⅚ bit true RMS handheld multimeter 3⅚ bit true RMS multimeter with bar chart display, DCV accuracy up to 0.5%. Additional measurement functions include capacitance, frequency, duty cycle, and temperature. High...
...: Fluke 283 FC/PV Solar Digital Multimeter and Wireless Current Clamp Unmatched safety and convenience for solar professionals The CAT III 1500 V/CAT IV 1000 V True-RMS Fluke 283 FC Digital Multimeter and a2...
High Performance Digital Multimeter Voltage Tester 200Ω 2kΩ 233g High Performance Drawbar Clamp Force Gauge Voltage Tester Description: True RMS The instrument can accurately measure the sine wave signal, but i...
...true RMS, DC voltage, frequency, duty cycle, resistance, capacitance measurement and line off, diode testing, temperature measurement. - The instrument has an automatic range function. - The meter has a read...
... ~ 500 Hz, true RMS), basic accuracy: ±1.5 % rdg. ±5 dgt. DC voltage 419.9 mV ~ 600 V, 5 ranges, basic accuracy: ±1.3 % rdg. ±4 dgt. AC ......
... test 6. True RMS Measurement 7. Average Measurement, 8. Date Hold 9. LCD Backlight 10. Low battery tips Specifications: Instrument in line with GB / T 13978-92 digital multimeter general technical condition...
...Digital Multimeter Multipurpose Keysight Agilent 34401A Digital Multimeter 6½ Digit 10 Measurement Functions The Agilent 34401A multimeter is a comprehensive testing toolkit. Beyond standard digital multimet...
Automatic Shutdown Diode Test Infrared Themometer IEC1010-I CAT 100V Description: - instrument for AC current, DC current, AC voltage sine wave true RMS, DC voltage, frequency, duty cycle, resistance, capacitan...
... (shorted at the AC voltage range and the input terminal) Word between a reading. These deviations are normal. Within the specified measuring range, they do not affect the accuracy of the multimeter to...
... safety certification for hazardous locations. Accuracy Specifications Accuracy specifications are displayed as ± (% of reading + digits) Measurement Range Accuracy DC Voltage: 0.1 mV to 1000 V ±(0.05% + 1) ...
Product overview: Fluke 287 True-RMS Electronics Logging Multimeter Now compatible with Fluke Connect® Mobile App The Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture quickly documents design...
kaemeasu 09A OEM ODM Digital Multimeter Ture RMS Current Voltage Measuring 2000 Counts Clamp Meter Product Overview Mini Digital Multimeter Household / Electrician / Circuit enthusiast A multimeter, short for "...
Fluke 233C Remote Display Digital Multimeter | Wireless True RMS Meter Accuracy Specifications Measurement Type Range Accuracy DC Voltage 0.1 mV to 1000 V 0.25% + 2 AC Voltage 0.1 mV to 1000 V 1.0% + 3 DC Curre...
... 600.0 A/2000 A (10 Hz to 1 kHz, true RMS rectification), basic accuracy 45 - 66 Hz: ±1.3% rdg. ±0.3 A (at 600 A) crest factor Measuring range 600.0 A: below 3; Measuring range ......
HIOKI AC Clamp Meter CM4141-50 Technical Specifications Parameter Specifications AC Current Range 60.00 A to 2000 A, 3 ranges (45 to 1 kHz, true RMS rectified) Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (range...
... CM4141-50 Technical Specifications Parameter Specifications AC Current Range 60.00 A to 2000 A, 3 ranges (45 to 1 kHz, true RMS rectified) Basic accuracy 45-66 Hz: ±1.5% rdg. ±0.08 A (range 60 A) Crest Fact...
... Parameter Specification AC Current Range 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 600.0 A (5 ranges, true RMS) Basic Accuracy (45-66 Hz) ±1.5% rdg ±5 dgt (60.00 mA to 6.000 A) ±2.5% rdg ±5 dgt (60.00 A to ......
...) AC current range 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A, 6 ranges, true RMS rectification Basic accuracy 45 Hz - 400 Hz: ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A), ±1.5% rdg ±5 dgt (60.......
... AC Current Range 6.000 mA, 60.00 mA, 600.0 mA, 6.000 A, 60.00 A, 200.0 A (6 ranges, true RMS rectification) Basic Accuracy (45 Hz - 400 Hz) ±1.0% rdg ±5 dgt (6.000 mA to 6.000 A) ±1.5% rdg ±5 dgt (60.......
Measuring DC & AC voltage Pocket multimeter Digital Multimeter Description: 1. Diode Test 2. Continuity Test, Automatic shutdown 3. Input impedance 4. Continuity Buzzer 5. Non-Contact Voltage test 6. True RMS M...