EPIQ 5 No signal at startup Replace Backend PC 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: No signal at startup Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within...
EPIQ 5 Startup Report Error 511 Replace ACQ 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Startup Report Error 511 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within...
GE Voluson E8 Ultrasound Repair Crash During Use And The Control Panel And Touch Screen Unusable 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Crash During Use And The Control Panel And Tou...
Aloka ARIETTA 70 All Probe Images No Echo Ultrasound Repair System 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: ALOKA ARIETTA 70 starts slowly, and there is no probe echo area after enteri...
Medical Equipment Hitachi Arietta 60 CELL Board EU-9160C Ultrasound Parts Repair Solutions 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Model: EU-9160C Note: Different faults are also able to be fixed. Know...
Replace Cell Board Aloka Hivision Ascendus Report Error Ultrasound Solutions 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: After checking the logs, it is found that the system reports a fai...
Repair GE Logiq S7/Logiq S8 Power supply CPS ASSY 6626600 R02, 5413249-3 1. Part number: 6626600 R02, 5413249-3 2. Compatible with GE Logiq S7, Logiq S8 3. With 60 days warranty 4. Maintenance time: 2-4 days Kn...
...h high failure rate&available in stock of this machine:CELL Board, CONT-B Board. ecer({videoId:"cNbtwKu4rME",videoId_local:"20220412_62554b9891dea.mp4",idContainer:"#VaYxuYa"}) Failure analysis and Troublesh...
IE33 Ultrasound Diagnostic System Repair IE33 System Reports Error The parts with high failure rate&available in stock of this machine: 1.CB Board (Channel Board)(453561156011/453561156012/453561156014/45356116...
Ultrasound Machine SIEMENS Acuson Antares The fault phenomenon After the Antares machine starts, the display stays at the SIEMENS interface, and the machine restarts automatically repeatedly. Failure analysis A...
Repair GE Logiq P5 SYSCONPM Board 5177848-3 1. Part number: 5177848-3 2. Compatible with GE Logiq P5 3. With 60 days warranty after fixed 4. Maintenance time: 2-4 days Note: Different faults are also able to be...
GE Vivid E9 Used Ultrasound Systems Repair GE Vivid E9 System Reports Error Failure phenomenon The GE Vivid E9 color Doppler ultrasound device restarts after booting through the Basic Input Output System (BIOS)...
IU22 Probe Frequency Ultrasound Repair IU22 System Reports Error Fault phenomenon After pressing the power button, the screen of the IU22 ultrasound device does not display an image. ecer({videoId:"pPPnJMVvgUU"...
Simens X150 Medical Equipment Assemble Repair Simens X150 System Reports Error Siemens ventilator has internal alarm system test function, technical error should be the test alarm system failure prompt. There a...
CX50 System Reports Error Failure phenomenon The machine has a blue screen when it is turned on and cannot be started normally. ecer({videoId:"Oi7FpnSDfQ4",videoId_local:"20211220_61c03c4e8ae52.mp4",idContainer...