...±0.2% Current Input current 3×1(6)A, 3×10(80)A Consumption <1VA Single phase rated current Accuracy class Error±0.2% Power Active, reactive, apparent power, error±0.5% Frequency 45~65Hz, Error±0.2% Metering Energy Active energy(Accuracy class: 0.5...
... Rated Voltage 3x380~456Vac L-L or 3x660~792Vac L-L (via direct connection) 3x100~120Vac L-L (via PTs) Reference Frequency 45~65Hz Power Consumption <0.5VA (each Phase) Current Input Rated Current 3x1(6)A AC...
... 30VA max/phase Resolution 0.01% Accuracy 0.05% Stability 0.01%/ 180s Distortion factor < 0.2% for linear resistance load Current Source Current Range 50mA – 120A Test current output 3*(1mA – 120A) Output Ca...
... Stability 3*(0V-450V) Max.3*20A 0.01% 0.05% 0.02%/120s Current Test current output Power of the current output Resolution Accuracy Stability 3*(1mA-120A) Max.3*100VA 0.01% 0.05% 0.02%/180s Phase angle Range...
...Meter Test Equipment Technical specification 1. Electrical output 1) Voltage and current measurement range Output voltage ranges: 57.7V/63.5V and 220V/240V (480V option) Output current ranges: 0.1A, 1A, 5A, ...
...Meter Multi Function LoRaWAN ELectric Meter Measures some or all of the following parameters: Voltage Current Real Power Reactive Power Apparent Power Power Factor Frequency Real Energy Reactive Energy Appar...
...Meter AC Power Analyzer Overview HS-1011 Energy Meter Power Consumption Tester is used for Measuring Energy Meter’s Power Consumption.This tester adopts high accuracy class current transformer,expanding meas...
... and time-sharing voltage active measurement Total and time-sharing current active measurement Real Time Measurement Real-time measurement of the phase voltage, current,total active power, total power factor...
...Meters With Non-Contact Voltage Detection,NCV and Ture RMS Features of AC Digital Clamp Meter AC Current Measurement AC & DC Voltage Measurement Resistance and buzzer measurement Low Battery Indication Over ...
... on the test line (optional L9788-11 or L9788-10) • 200mA continuous test check • Capable of measuring AC/DC voltage,...
...Current Transformer for Switchgear 1. Product Introduction: LXSZC-36 adopts newly high permeability core with high measuring accuracy. Secondary winding fully enclosed vacuum casting in antiflaming plastic s...
...Meter Test System for Precise AC/DC Voltage and Current Output Specifications Environment Safety Operation Temperature Relative Humidity Altitude IP Class Conformity 20℃-30℃ 40%-85% <2500m 40 IEC General Specification Power supply AC 220V±15% or 110V±15% Frequency 50Hz~60Hz Power consumption 100VA-1000VA Size & Weight 658*440*220(mm),30kg AC Voltage Output DC voltage output Three-phase AC high voltage......
ADL200 Single Phase Electric Meter With Modbus Single-phase electronic energy meter ADL200 is mainly used to measure single-phase active energy of low-voltage network, and can measure voltage, current, power an...
...Meter RS485 electronic power meter AC digital amp meter AMC48-AI Panel Meter RS485 electronic power meter AC digital amp meterUsing AC sampling technology, you can directly or indirectly measure the power, v...
... J increase capacity 1 design serial number 0.66 rated voltage (kV). Mainly used for indoor, rated voltage of 0.66kV and below the rated frequency of AC circuit 50Hz as current and electric energy measuremen...
High Accuracy Split Core Current Transformer for Energy Metering Systems The CP Series Low Voltage Current Transformer delivers precise current measurement and energy monitoring capabilities for electrical syst...
..., it can be used to measure the three phase voltage, current and phase angle, frequency, power, power factor and so on. Features 1. Three-phase voltages and four channel current (including neutral line curre...
...Clamp Meter Current Voltage Resistance Capacitance,LPF, T-RMS Instrument This clamp meter is a portable, handheld professional meter that measures AC/DC voltage, AC current,Capacitance, resistance. Features:...
...Back Light Frequency (Clamp) and Frequency (Voltage) Auto Range and V/Ω/A Auto Scan Continuity and NCV test Specifications Range Accuracy DC Voltage 0.5~600V ±(0.5%+3) AC Voltage 1.0~600V ±(0.8%+5) AC Curren...