| Sign In | Join Free | My burrillandco.com |
|
...testing, analyzing and assessing power system circuit breakers, mechanical characteristics of load switches and isolated switches and other AC high voltage switches, contact resistance, Arcing contacts and v...
... 50Hz, rated voltage 440V and below, dc voltage 240V below and rated current to the electrical wiring 63A for manual less frequent switching circuit breaker or controlling and conversion, may also directly c...
...voltage vacuum circuit breaker The ZW7-40.5 outdoor HV vacuum breaker is a kind of outdoor HV switching devices used in three-phase AC 50Hz. 40.5kV. It uses spring operating mechanism or electromagnetic oper...
...Voltage Protection Devices , Dynamic Reactive Power Regulator General Description KCS series capacitive no-contact switch is electronic power controller for switching quickly on/off power shunt capacitor, co...
... , 3150A and 4000A contact box , club contact , fix contact, arm contact and jaw contact . 630A and 1250A VS1 circuit breaker . 630A and 1250A ZN85-40.5 circuit breaker . 12KV and...
... and other AC high voltage switches, contact resistance, Arcing contacts and vibration characteristics etc. This Circuit Breaker Timing Test Set covers all testing items of high voltage circuit breaks. Major...
... ZN63A VS1-12 HV Indoor vacuum circuit breaker Main application VS1-12 type indoor high voltage vacuum circuit breaker is the indoor switch device for three-phase AC 50Hz, rated voltage 12kA power system, ca...
...voltage 12kv vacuum circuit breaker ZW32-12 series pillar type outdoor vacuum high-voltage circuit breaker is a kind of outdoor high-voltage switch equipment of three phase frequency 50HZ,rated voltage 12kv....
...Switch 126KV with Earthing Switch GW4 series outdoor AC HV disconnecting switch is an outdoor HV switch of three-phase AC50 Hz, it is suitable for power system of rated voltage 35kV, is used for disconnectin...
...Voltage Disconnecting Switch Disconnect for Power Station GW4 Disconnect Switch: This type disconnector is a kind of HV outdoor electric equipments used in three-phase AC 50Hz electrical system . It is used ...
...-60Hz. Used for breaking and isolating the circuit, maintenance personnel can clearly see whether the circuit is separated, to ensure their safety. The innovative structure of disconnector is also fabricated...
... 33kv 40.5kv 72.5kv , three phase, AC 50-60Hz. Used for breaking and isolating the circuit, maintenance personnel can clearly see whether the circuit is separated, to ensure their safety. The innovative stru...
...voltage load breaker switch Product Description vZhejiang xinkou power equipment co.,ltd is a high-tech enterprise, specializing in developing, design, manufacture, sales, import and export of low voltage an...
...Switch Disconnector Pole mounted Isolating Switch Of High Voltage Description of GW4 Disconnect Switch: This type disconnector is a kind of HV outdoor electric equipments used in three-phase AC 50Hz electric...
... ZW7-40.5 outdoor high voltage vacuum circuit breaker is used for AC three-phase power system with 50Hz and voltage of 40.5KV, which is used for breaking, closing load current, overload current and short cir...
...Circuit Switch Fast Switching Times Battery Powered 3Ohm Product Status Active Switch Circuit SPST - NO Multiplexer/Demultiplexer Circuit 1:1 Number of Circuits 1 On-State Resistance (Max) 3Ohm Channel-to-Ch...
...Circuit Switch Signal Switching Rail-To-Rail Operation 200Ohm Product Status Active Switch Circuit SPST - NC Multiplexer/Demultiplexer Circuit 1:1 Number of Circuits 4 On-State Resistance (Max) 200Ohm Channe...
...Circuit Switch Fast Switching Audio And Video Routing Product Status Active Switch Circuit SP4T Multiplexer/Demultiplexer Circuit 4:1 Number of Circuits 2 On-State Resistance (Max) 100Ohm Channel-to-Channel ...
...Circuit IC Switch Continuous Current Fast Switching 100mA Product Status Active Switch Circuit SPST - NC Multiplexer/Demultiplexer Circuit 1:1 Number of Circuits 4 On-State Resistance (Max) 5Ohm Channel-to-C...