...transformer, for DC/DC Converters, Designed for use with Texas Instruments UCC287xx, UCC289xx Trader part number 750312723 Our part number ST2723NL Pin-to-pin equivalent YES Type For DC/DC Converters Applica...
... Chipset Manufacturer Texas Instruments Voltage - Primary - Voltage - Auxiliary - Voltage - Isolation 1500Vrms Inductance @ Frequency 1mH @ 10kHz Frequency 10kHz Operating Temperature -40°C ~ 125°C Mounting ...
...VOLTAGE TRANSFORMER ELECTRONIC DRIVE TRANSFORMER High voltage transformers are normally used in high voltage labs for testing purpose. This transformer is subjected to transient voltages and surges during th...
... is that, as their name implies, they operate at much higher frequencies — while most line voltage transformers operate at 50 or 60 Hz, high-frequency transformers use frequencies from 20 KHz to over 1MHz.Op...
...Transformer 749197111 Characteristics Transformer with 6 identical windings Power up to 300 W possible Isolation voltage 500 VDC Low leakage inductance Operating temperature: –40 °C to +125 °C Applications A...
...Transformer with 6 identical windings 749197221 Characteristics Transformer with 6 identical windings Power up to 300 W possible Isolation voltage 500 VDC Low leakage inductance Operating temperature: –40 °C...
...Transformer 749197301 Characteristics Transformer with 6 identical windings Power up to 300 W possible Isolation voltage 500 VDC Low leakage inductance Operating temperature: –40 °C to +125 °C Applications A...
...Transformer 749196121 Characteristics Transformer with 6 identical windings 4 sizes with 5 different lengths of air gap each Isolation voltage 500 VDC Low leakage inductance Operating temperature: –40 ºC to ...
... VDC Low leakage inductance Operating temperature: –40 ºC to +85 ºC Applications All kind of switching regulators - Flyback converters - Forward converters - Push-pull converters - Step-up/step-down converte...
... VDC Low leakage inductance Operating temperature: –40 ºC to +85 ºC Applications All kind of switching regulators - Flyback converters - Forward converters - Push-pull converters - Step-up/step-down converte...
... leakage inductance Operating temperature: –40 ºC to +125 ºC Switching Frequency : 250KHz to 550KHz Applications All kind of switching regulators - Flyback converters - Forward converters - Push-pull convert...
... leakage inductance Operating temperature: –40 ºC to +125 ºC Switching Frequency : 250KHz to 550KHz Applications All kind of switching regulators - Flyback converters - Forward converters - Push-pull convert...
... leakage inductance Operating temperature: –40 ºC to +125 ºC Switching Frequency : 250KHz to 550KHz Applications All kind of switching regulators - Flyback converters - Forward converters - Push-pull convert...
...Transformer high frequency transfomer Characteristics Transformer with 6 identical windings 4 sizes with 5 different lengths of air gap each Isolation voltage 500 VDC Low leakage inductance Operating tempera...
...Transformer high frequency transfomer Characteristics Transformer with 6 identical windings 4 sizes with 5 different lengths of air gap each Isolation voltage 500 VDC Low leakage inductance Operating tempera...
... widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 36 kV. Remarks: Upon request we ...
...Transformer For Isolated telecom converters 750311692 Characteristics Easy design-in solution Less external components needed Small board space Low cost No optocoupler needed! Long term reliability voltage c...
...Transformer for Isolated telecom converters 750370047 Characteristics Easy design-in solution Less external components needed Small board space Low cost No optocoupler needed! Long term reliability voltage c...
... to measure the current, electric energy and protective relaying in single phase or three phase AC circuit with the frequency 50Hz or 60Hz and highest voltage for equipment 17.5/24 kV. The...
... enclosed construction, is used indoor for measuring current, electric energy and protective relaying in the electric system with the frequency 50Hz or 60Hz and highest voltage for equipment 7.2/12kV, Be sui...