| Sign In | Join Free | My burrillandco.com |
|
... Temperature Sensor: NTC10K/NTC2.2K/PT100/PT1000 Installation Interface: NPT3/4 Electrode Cable: Standard 10m >>Principle Since water contains various dissolved salts that...
...Conductivity EC 20μS/cm Sensor Resistivity Sensor >>Technical Parameter Conductivity Range: 0.01~20μS/cm Resistivity Range: 0.01~18.2MΩ·cm Electrode Mode: 2-pole Electrode Constant: K≈0.01 Wetted Material:...
...Conductivity Sensor Resistivity Sensor >>Technical Parameter Conductivity Range: 0.01~20μS/cm Resistivity Range: 0.01~18.2MΩ·cm Electrode Mode: 2-pole Electrode Constant: K≈0.01 Wetted Material: 316L Tempe...
...Conductivity EC 20μS/cm Sensor Resistivity Sensor >>Technical Parameter Conductivity Range: 0.01~20μS/cm Resistivity Range: 0.01~18.2MΩ·cm Electrode Mode: 2-pole Electrode Constant: K≈0.01 Wetted Material:...
...Conductivity EC Sensor Resistivity Sensor >>Technical Parameter Conductivity Range: 0.01~20μS/cm Resistivity Range: 0.01~18.2MΩ·cm Electrode Mode: 2-pole Electrode Constant: K≈0.01 Wetted Material: 316L Te...
...: 0℃~150℃ Pressure Resistance: 0~2.0 MPa Temperature Sensor: PT1000 Installation Interface: Chuck 50.5 Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in...
...Conductivity TDS Sensor in 80℃ Working Condition >>Technical Parameter Conductivity Range: 0.01~20 μS/cm Resistivity Range: 0.01~18.2 MΩ·cm Electrode Mode: 2-pole Electrode Constant: K ≈ 0.01 Junction Mate...
... Temperature: 0℃~200℃ Pressure Resistance: 0~2.0 MPa Temperature Sensor: PT1000 Installation Interface: NPT 3/4" Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in the...
... Temperature Sensor: NTC10K/NTC2.2K/PT100/PT1000 Installation Interface: NPT1/2’’ Electrode Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in the form of ions, when...
...Conductivity 200μS/cm EC Sensor TDS Sensor >>Technical Parameter Conductivity Range: 0.01~200μS/cm Electrode Mode: 2-pole Electrode Constant: K≈0.1 Wetted Material: 316L Temperature Range: 0~60℃ Pressure R...
... Rating: 0~2.0MPa Temperature Sensor: PT1000 Installation Interface: Upper NPT3/4, down NPT1/2 Electrode Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in the form of...
...: NTC10K/NTC2.2K/PT100/PT1000 Installation Interface: Upper NPT3/4, down NPT3/4 Electrode Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in the form of ions,...
... Rating: 0~2.0MPa Temperature Sensor: PT1000 Installation Interface: Upper NPT3/4, down NPT3/4 Electrode Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in the form of...
...Conductivity TDS Sensor >>Technical Parameter Conductivity Range: 0.01~1000 μS/cm Electrode Mode: 2-pole Electrode Constant: K ≈ 0.1 Junction Material: 316L Temperature: 0℃~80℃ Pressure Resistan...
... Temperature Sensor: NTC10K/NTC2.2K/PT100/PT1000 Installation Interface: NPT1/2’’ Electrode Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in the form of ions, when...
...Conductivity 5000μS/cm EC Sensor TDS Sensor >>Technical Parameter Conductivity Range: 0~5000μS/cm Electrode Mode: 2-pole Electrode Constant: K≈1 Wetted Material: 316L Temperature Range: 0~60℃ Pressure Rati...
...Conductivity EC 5000μS/cm Sensor TDS Sensor >>Technical Parameter Conductivity Range: 1~5000μS/cm Electrode Mode: 2-pole Electrode Constant: K≈0.1 Wetted Material: 316L Temperature Range: 0~80℃ Pressure Ra...
... Rating: 0~2.0MPa Temperature Sensor: PT1000 Installation Interface: Upper NPT3/4, down NPT1/2 Electrode Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in the form of...
... Rating: 0~2.0MPa Temperature Sensor: PT1000 Installation Interface: Upper NPT3/4, down NPT3/4 Electrode Cable: Standard 10m >>Principle Since water contains various dissolved salts that exist in the form of...
...: 0-0.3MPa Temperature Sensor: NTC10K/NTC2.2K/PT100/PT1000 Installation Interface: PG13.5 Cable: Standard 5m >>Principle Since water contains various dissolved salts that exist in the form of ions, when...