... measuring big pipe diameter, which is built-in RTD module. When it is equipped with PT100 temperature sensor, ST502 can be upgraded into energy meter used for measuring individual energy consumption in any ...
... measuring big pipe diameter, which is built-in RTD module. When it is equipped with PT100 temperature sensor, ST502 can be upgraded into energy meter used for measuring individual energy consumption in any ...
...RTD, T/C, Ohm or mV input Single or dual (difference or average) sensor input DIN form B headmount HART Multidrop capable NAMUR NE43 sensor error response Configurable using STT17C configuration tool and PC ...
...wire) Sensor type PT100,PT200,PT500,PT1000,Nl120 Temperature range Resistance measurement/-200~+ 800 degrees (PT sensor)-79~+ 309 degrees(NI sensor) Resolution 0.1℃/ digit Isolated withstand voltage 0.005 Pr...
1.Features: Using industrial-grade CPU.strong anti-intergerence ability:Multiple input signal and output types are available. Multiple alarm types,Suitable for the use of different applications,Stable and relia...
1.Features: Using industrial-grade CPU.strong anti-intergerence ability:Multiple input signal and output types are available. Multiple alarm types,Suitable for the use of different applications,Stable and relia...
... input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HAR...
... of the TTH200 transmitter with the addition of two indicator LEDs. A green LED indicates that the transmitter is powered. A red LED would indicate a fault in either the unit or the sensor. TTR200 units can ...
... of the TTH200 transmitter with the addition of two indicator LEDs. A green LED indicates that the transmitter is powered. A red LED would indicate a fault in either the unit or the sensor. TTR200 units can ...
...Filter Rating Configurable:0-3, default: 1 Supported Sensor Types PT100 / PT1000/ PT200 / PT500 / Cu100 / KTY84-130 / KTY83-122 / NTC5K/NTC10K/NTC10K221/resistance2000Ω/Ni120 Temperature Range Resistance mea...
Bently Nevada 3500/65 16-Channel Temperature Monitor 3500/65-01-00 145988-02 172115-01 Description The 3500/65 monitor provides 16 channels of temperature monitoring and accepts both resistance temperature dete...
...Temperature Pressure Flow Rate Monitoring System >>Overview The AG-TPF07 Temperature-Pressure-Flow Monitor consists of a Pitot tube, resistance temperature detector (RTD), differential/absolute pressure sens...
...Temperature Transmitters YTA50/YTA70 The YTA50 and YTA70 are head mount type of temperature transmitters that conform to the standard DIN formB head mounting. Features: Outstanding performance Microprocessor...
...Temperature Transmitters YTA50/YTA70 The YTA50 and YTA70 are head mount type of temperature transmitters that conform to the standard DIN formB head mounting. Features: Outstanding performance Microprocessor...
... are temperature-sensing instruments that are easily portable, have permanent probes, and a convenient digital display. The way a digital thermometer works depends upon its type of sensor. Sensor types inclu...
... are temperature-sensing instruments that are easily portable, have permanent probes, and a convenient digital display. The way a digital thermometer works depends upon its type of sensor. Sensor types inclu...
... The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accep...
ROHS Endress Hauser iTEMP TMT31 temperature transmitter TMT31-AAA1B1A1 4-20 mA temperature transmitter as head or DIN rail device with one RTD or one TC sensor input suitable for use in zone 2 (Ex ec) / Div. 2 ...
Ceramic Thermocouple Head Terminal Block 1. Terminal Block Brief Introduction Terminal block (also called connection blocks, connection board), material is ceramic, means terminating the process sensor (therm...
... input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HAR...