| Sign In | Join Free | My burrillandco.com |
|
... 55% coverage Jacket 0.268"±0.006"/6.81±0.15mm PVC Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall b...
... Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance 87.5Ω/KM at 20℃ Capacitance 67 ±3 pF/m Impedance 75 ± 3 Ω ......
... copper braid wire 55% coverage Jacket 6.7±0.15mm PVC Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shal...
... copper braid wire 55% coverage Jacket 6.7±0.15mm LSZH Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ sha...
...CATV coaxial Cable NO.7100443 Construction Parameters: Inner Conductor 0.04"/1.00mm/18AWG BC Dielectric 4.6mm FPE Shield 1 4.75mm overlapped copper foil Shield 2 16*4*0.12mm bare copper braid wire 55% covera...
...CATV coaxial Cable NO.7100444 Construction Parameters: Inner Conductor 0.04"/1.00mm/18AWG BC Dielectric 4.6mm FPE Shield 1 4.75mm overlapped copper foil Shield 2 16*4*0.12mm bare copper braid wire 55% covera...
...CATV coaxial Cable NO.7100445 Construction Parameters: Inner Conductor 0.05"/1.25mm/16AWG BC Dielectric 5.5mm 5 cell air spaced PE Shield 1 4.75mm overlapped copper foil Shield 2 16*6*0.12mm bare copper brai...
... copper braid wire 60% coverage Jacket 7.8±0.20mm LSZH Jacket Thickness 0.030"/0.76mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ sha...
...CATV coaxial Cable NO.7100447 Construction Parameters: Inner Conductor 0.065"/1.67mm/14AWG BC Dielectric 7.28mm 5 cell air spaced PE Shield 1 overlapped copper foil Shield 2 16*6*0.12mm bare copper braid wir...
...CATV coaxial Cable NO.7100448 Construction Parameters: Inner Conductor 0.065"/1.67mm/14AWG BC Dielectric 7.28mm 5 cell air spaced PE Shield 1 overlapped copper foil Shield 2 16*6*0.12mm bare copper braid wir...
...CATV coaxial Cable NO.7100449 Construction Parameters: Inner Conductor 0.091"/2.33mm/11AWG BC Dielectric 10.06mm 5 cell air spaced PE Shield 1 overlapped copper foil Shield 2 16*6*0.15mm bare copper braid wi...
...CATV coaxial Cable NO.7100450 Construction Parameters: Inner Conductor 0.091"/2.33mm/11AWG BC Dielectric 10.06mm 5 cell air spaced PE Shield 1 overlapped copper foil Shield 2 16*6*0.15mm bare copper braid wi...
... 0.030"/0.76mm Messenger 0.109" /2.77mm Steel Max.Breaking Strength of Messenger(kgf) 816 Application For Use in Longer CATV Run Lengths Electrical Characteristics:...
...CATV coaxial Cable NO.7100403 Construction Parameters: Inner Conductor 0.137"/3.48mm/7AWG CCA Dielectric 0.565"/14.35mm Foamed PE Shield 1 0.625"/15.88mm Welding Smooth Aluminum Tube Shield Thickness 0.030"/...
...CATV coaxial Cable NO.7100404 Construction Parameters: Inner Conductor 0.163" /4.14mm/ 6AWG CCA Dielectric 0.653"/16.59mm Foamed PE Shield 1 0.703"/17.86mm Welding Smooth Aluminum Tube Shield Thickness 0.025...
...CATV coaxial Cable NO.7100405 Construction Parameters: Inner Conductor 0.167" /4.24mm/ 6AWG CCA Dielectric 0.681"/17.32mm Foamed PE Shield 1 0.75"/19.05mm Welding Smooth Aluminum Tube Shield Thickness 0.034"...
...CATV coaxial Cable NO.7100411 Construction Parameters: Inner Conductor 0.129"/3.28mm/8AWG CCA Dielectric 0.519"/13.2mm Foamed PE Shield 1 0.565"/14.35mm Welding Smooth Aluminum Tube Shield Thickness 0.023"/0...
... PE Black Jacket Thickness 1.27mm Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <1.33 Ω/km Capacitance 50 ± 3 pF/m ......
....03mm PE Black Jacket Thickness 0.76mm Messenger 2.11mm Steel Wire Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <10.76 Ω/km Capacitance 50 ± 3 ......
... 15.49mm PE Black Jacket Thickness 0.89mm Messenger 2.77mm Steel Wire Application For Use in Longer CATV Run Lengths Electrical Characteristics: Inner Conductor Resistance The Max. at 20℃ shall be <3.34 Ω/km Capacitance 50 ± 3 pF/m ......