| Sign In | Join Free | My burrillandco.com |
|
...Transformer 117V 234V 2.27A Features 1). Installation method:Sub-plate mount 2). Flame resistance:UL94-V0 3). Work temperature:-30℃~+40℃ 4). Withstand voltage:4.5KV AC 5). Waterproof:IP00 6). Use:Audio,Light...
...Welding Power Over Ethernet Transformer ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 3-5 @20°C 0.043 ohms max D.C. RESISTANCE 2-1 @20°C 0.130ohms ma...
Small Signal Transformer In Ferrite Core PCB Mounted ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 1-2 @20°C 0.270 ohms max D.C. RESISTANCE 3-5 @20°C 0....
...Transformer D Electrical Properties: Properties Test conditions Value Unit Tol. Inductance 10 kHz/ 100 mV L 1080 μH min. Leakage inductance 100 kHz/ 100 mV LS 5.0 μH max. DC Resistance 1 RDC 1300 mΩ max. DC ...
... max D.C. RESISTANCE 10-6 @20°C 0.286 ohms max INDUCTANCE 2-4 10KHz,10mVAC,Ls 72uH min LEAKAGE INDUCTANCE 2-4 tie(6+7+8+9+10),......
...Transformer for Analog Devices AduM347x Quad-Channel Digital Isolators ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 2-4 @20°C 0.124 ohms max D.C. RE...
...High Frequency Small Signal Transformer ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C. RESISTANCE 1-2 @20°C 0.092 ohms max D.C. RESISTANCE 3-5 @20°C 0.036ohms ma...
Electrical Specifications of 7490240140 SMT Transformer: Parameter Test conditions Value Unit Tol. Turn Ratio(2%) 11 Inductance 100 kHz / 100 mV @ 8 mA 350 H min. Insulation Test Voltage 1 min. 4000 V (RMS) ...
ZX-YJS Insulation Oil Tan Delta Tester Product introduction ZX-YJS Insulation Oil Tan Delta Tester is a high-precision integrated testing instrument designed and manufactured according to GB/T5654-2007 measurem...
...accords with: IEC 60044-2/IEC 61869-1&3 Voltage transformer with fully enclosed cast insulation structure, the primary and secondary windings and toroidal cores are all encapsulated in epoxy casting body for...
...transformer winding due to its excellent electrical conductivity and other favorable properties. Here are some details about the use of 1060 aluminum coil for transformer winding: Electrical Conductivity: 10...
Toroidal Power Transformer Coil Winding Machine Wire Guide Nozzle/Stainless Steel Nozzle/Wire Guide Tube Description of tungsten carbide coil winding nozzle : Tungsten carbide wire guide nozzles(Coil winding no...
EP-182DG Power Over Ethernet Transformer Led Driver Electronic Transformer ELECTRICAL SPECIFICATIONS @ 25°C UNLESS OTHERWISE NOTED: PARAMETER TEST COMDITIONS VALUE D.C. RESISTANCE 1-3 @20°C 0.315 OHMS ±10%. D.C...
MID-PPTI Push-Pull Transformers SMPS Flyback Transformer 760390013 ELECTRICAL SPECIFICATIONS @25°C unless otherwise noted: PARAMETER TEST CONDITIONS VALUE D.C RESISTANCE 1-3 @20°C 0.419 ohms max D.C RESISTANCE ...
... chargers Metering Process controls Factory automation Security systems Garage door opener auxiliary supplies Electrical Properties: PARAMETER TEST CONDITIONS VALUE D.C.RESISTANCE 3-1 @20℃ 0.650 ohms ±10% D....
...Resistance , True RMS Megohmmeter I. Product Introduction : UT505A is a kind of handled insulation resistance tester, which has the parameters such as insulation resistance, AC/DC voltage and etc. This machi...
...Resistance , True RMS Megohmmeter I. Product Introduction : UT505A is a kind of handled insulation resistance tester, which has the parameters such as insulation resistance, AC/DC voltage and etc. This machi...
This tester is mainly used to measure the transformer on-load tap-changer transition waveform, transition time, the instantaneous transition resistance, three-phase synchronization and so on. The instrument fea...
...Transformer 24VAC 1600mA Universal Ac Power Adapter With CE Approval Application: Audio,Air Pum,LED lighting. Specification Datasheet Table Primary rated voltage and frequency: 230VAC 50Hz. FULL LOAD RATED ...
...Transformer EI#57 AC-AC ADAPTOR Used For Outdoor LED Lighting ~ SPECIFICATION ~ Input 230VAC 50Hz Output 24VAC 1.6A D.C.Resistance:Primary /Ω±15%,measured at25℃. Insulation resistance 500VDC supplied,100M oh...