| Sign In | Join Free | My burrillandco.com |
|
... 12 Ω Primary Current 4 mA Insulation (Winding to Body) 4 kV Secondary Voltage 20 Ω Core Materail Coiled Silicon Steel Sheet Outer Case Materail Insulation Tape Busbar Type None Mounting Method Through Hole ...
...current transformer Zero Sequence Current Transformer for SMPS 4KV Brand WSD Structure Of Winding Toroidal Phase Single Usage Current Model WSD-03-03B-1 Turns Ratio 1:200 Resistance 12 Ω Primary Current 2A/1...
...Type 10kv 11kv 12kv Outdoor CT Current Transformer 1.rated insulation level: 12/42/75kV 2.rated frequency: 50/60Hz 3.burden power factor): COSØ=0.8 lagging 4.technical standard accords with):outdoor 5. techn...
...:common product not exceed 1000m,plateau type product not exceed 4000m. Main Technical data: Rated insulation:12/42/75kV(10kV products),40.5/95/185kV(35kV products). Rated frequency:50Hz or 60Hz Rated second...
Single Phase Split Core Current Transformer CT Clamps For Protection Measurement 1.Product Description A Split Core Current Transformer is a specialized type of current - measuring device that stands out for it...
High Accuracy Clamp On Current Transformer CT 0.1A~2000A Split Core Current Transformer Clamp On Type The HM-CTC1535 is a high performance AC clamp on Current transformer with excellent transformation and low p...
High Accuracy Clamp On Current Transformer CT 0.1A~2000A Split Core Current Transformer Clamp On Type The HM-CTC1535 is a high performance AC clamp on Current transformer with excellent transformation and low p...
... resin casting type CT Technical data The current transformers are in accordance with GB20840.2 and IEC61869-2 standards Rated insulation level: 12/42/75kV Rated frequency: 50Hz or 60Hz Rated secondary curre...
...current transformer U type brass terminal doule hinge 2 phase 2000T CT with Busbar Suitable for high precision, small phase error requirments of three-phase electric energy meters More space in the meter...
...current transformer power stealing prevention DC immune magnetic interference 300mT - 500mT bus type CT Suitable for high precision, small phase error requirments of three-phase electric energy meters Mo...
...type Zero-phase earth leakage output 22mA What is the APPLICATION of our WSD-ZCT529 Zero-phase earth leakage current transformer ? electronic energy meter power transducer precision power meter and other pow...
... a current in its secondary which is proportional to the current in its primary. Current transformers, along with voltage or potential transformers, are instrument transformers. Instrument transformers scale...
...Current Transformer Indoor Bushing Current Transformer 1. Main technical parameter Rated primary current: 50-1500A Rated secondary current: 5A or 1A Rated voltage: 30kV or 33kV or 34.5kV or 35kV etc Accuracy...
... metering,submetering applications,which hasSmall size,easy installation,it is safer and portable than other current transformer. Drawing Size Model I.D. Ratio Rated Amps Accuracy YM-SCT-T06 6mm 1000:1 1, 5,...
... device because it converts high AC current to small easily manageable value. 2.Current transformers consist of primary winding, secondary winding, magnetic core and insulated body. 3.If current transformers...
Small Split Core LV Current Transformers , Ac Ct Current Transformer Safety small current transformer with split core current transformer BH-0.66 II series current transformer is new in its magnetic circuit des...