Sign In | Join Free | My burrillandco.com
Home > Other Chemical Reagents >

Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA

    Buy cheap Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA from wholesalers
     
    Buy cheap Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA from wholesalers
    • Buy cheap Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA from wholesalers
    • Buy cheap Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA from wholesalers
    • Buy cheap Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA from wholesalers
    • Buy cheap Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA from wholesalers
    • Buy cheap Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA from wholesalers

    Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA

    Ask Lasest Price
    Brand Name : Zecen
    Model Number : Inflammation Monitoring Test Kit
    Certification : CE, ISO13485
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000 Set/Sets per Month
    Delivery Time : 10 workdays
    • Product Details
    • Company Profile

    Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA

    Inflammation Monitoring Test Kit for Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA




    Inflammation MonitoringIL-6

    IL-6 is mainly produced by macrophages, T cells, B cells and other cells. It can regulate the growth and differentiation of various cells, regulate immune response, acute phase response and hematopoietic function, and play an important role in the body's anti-infection immune response. IL-6 is significantly altered in a variety of diseases. The dysregulation of IL-6 expression can cause many diseases, and its clinical manifestations are mainly increased IL-6 levels during the onset. The elevated level of IL-6 is closely related to the active stage of the disease, the development and change of the tumor, the degree of rejection and the treatment effect. Therefore, the detection of the level of IL-6 in the patient's body fluid can reflect the change of the patient's condition. This product can be used to evaluate infections, tissue damage and inflammatory diseases, and can also be used as an aid in the identification of cardiovascular disease risk.

    PCTElevated PCT levels are seen in bacterial sepsis, especially severe sepsis and septic shock.
    PCT can be used as a prognostic indicator of sepsis, as well as for acute severe pancreatitis and its major complications
    On target. PCT can be used as anti-respiratory agent in patients with community-acquired respiratory tract infections and air-conditioned pneumonia
    The index of biogenic selection and efficacy judgment.
    CRPRoutine CRP assays include qualitative, semi-quantitative, and quantitative assays and can be used to evaluate infections, tissue damage, and inflammatory diseases. For routine CRP assays, reference values are generally considered to be clinically higher than 10 mg/L. CRP levels in the blood of healthy people are less than 5 mg/L, while under various conditions, CRP values reach about 20 to 500 mg/L within 4 to 8 hours of acute inflammation. Conventional CRP is more sensitive and reliable than erythrocyte sedimentation rate (ESR) and white blood cell count as an assessment of acute inflammation.
    SAAThe full name of SAA is serum amyloid A, which is an acute phase reaction protein secreted into serum after being produced by hepatocytes.
    White, when the body is infected or injured, it can ly increase by about 1000 times within 4-6 hours. After the body's antigens are cleared, it can quickly return to normal levels, so SAA can be used as a sensitive indicator to reflect the body's infection and inflammation recovery. Compared with the current widely used CRP in clinical practice, the difference of SAA is that its elevation is commonly seen in viral, mycoplasma, and bacterial infections, and its sensitivity is higher than that of C-reactive protein.
    Elevated C-reactive protein is more common in bacterial infections, but only mildly elevated in pathogens such as viruses and mycoplasma
    or not elevated. While SAA is a sensitive indicator for diagnosing viral and bacterial infections, SAA and C.
    Compared with reactive protein, the main advantage is that it rises earlier and the rise range is larger, and the sensitivity is higher. Especially in the early stage of acute bacterial infection, the advantage of detecting SAA is more obvious, and SAA is significantly increased in viral infections, but C-reactive protein does not increase. Therefore, SAA can be used as a sensitive indicator for the diagnosis of viral infection.




    Quality Inflammation Monitoring Test Kit IVD Products For Chemiluminescence Immunoassay Analyzer IL-6 PCT CRP SAA for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Taizhou Zecen Biotech Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more IVD Products products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0