Sign In | Join Free | My burrillandco.com
Home > Other Wires, Cables & Cable Assemblies >

Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal

    Buy cheap Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal from wholesalers
     
    Buy cheap Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal from wholesalers
    • Buy cheap Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal from wholesalers
    • Buy cheap Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal from wholesalers

    Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal

    Ask Lasest Price
    Brand Name : MICH
    Model Number : EHTTSOTU
    Certification : ISO9001
    Price : USD0.5-USD5 per meter
    Supply Ability : 10 million meters per year
    Delivery Time : in one month
    • Product Details
    • Company Profile

    Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal

    Electric Heat Tracing Technical Solution for Oil Terminal Use is an electric heat trace technology package which can be selected to be used on the pipelines, tanks, valves etc related to the oil terminals based on the project conditions and requirement. In winter, the climate is cold and the temperature is too low, which may lead to serious blockage of the oil pipeline when it arrives at the gathering and transmission pump station due to the heat loss and wind speed, etc., and the material in the pipeline cannot be normally transported. In order to solve the problem of oil pipeline freezing, the electric heat tracing solution should be used to heat all the main pipelines on the wharf.


    Through the field investigation, including the local temperature, low temperature, wind speed, and from the safety point of view, for the long oil transmission pipeline of large diameter, the occasion of high heat tracking temperature, and combined with the heat loss of comprehensive consideration, the constant power electric heating trace should be used, because the highest maintenance temperature can reach 150℃, and the highest exposure temperature is 205 degrees, which can completely maintain the normal operation of the oil pipeline. For longer pipelines, the use of series constant power electric heating insulation products, the electric tracing is large and the service length is longer, up to thousands of meters. While for the transmission distance is not long, for higher safety, corrosion resistance consideration and other high requirements, mineral insulation heating cable can be considered. For the distance to be at least 5 kilometers, the skin effect heating solution can be considered.


    The series constant power electric heating tracing product is 5~12 times longer than the general constant power and self-limiting temperature electric tracing, so it is especially suitable for long distance transmission pipelines in petroleum, chemical industry, electric power, wharf and other industries.


    In the performance of electric heat trace products, the outer layer of electric tracing belt has metal shielding braided layer, which not only has the function of heat transfer and heat dissipation, but also can improve the overall tensile strength of electric heating, and can also be used as a safe grounding wire.


    Table 2 Heating Cable Specification (600V Single Conductor)


    Cable CodeDiameterHDPE DiameterStandard resistance value at +20Maximum Production LengthUnit weight
    mmmmΩ/mmkg/km
    16C1.78.2100.0017350366.54
    16C2.27.69.40.0022380307.77
    16C2.97.08.80.0029400264.45
    16C45.97.70.004600190.88
    16C75.37.10.007600154.08
    16C114.96.70.011600132.25
    16C134.66.40.013600 (300)☆125.7
    16C174.66.40.017600 (300)☆117.16
    16C214.66.40.021600 (300)☆111.9
    16C253.75.50.025600 (480)☆68.83
    16C333.75.50.033600 (480)☆63.76
    16C403.45.20.04600 (560)☆58.87
    16C633.250.06360051.47
    16K806.88.60.08370 (140)☆254.18
    16K1005.270.1450 (240)☆162.11
    16K1404.96.70.14600 (270)☆122.55
    16K1974.456.250.197600 (330)☆111.32
    16K2204.56.30.22600 (330)☆102.89
    16K3154.36.10.315600 (350)☆91.44
    16K3454.26.00.345600 (370)☆85.9
    16K4504.05.80.45600 (400)☆80.73
    16K6304.05.80.63600 (400)☆77.26
    16K8003.55.30.8600 (530)☆61.48
    16K12502.84.61.2560040.83
    16K20002.84.62.060038.96

    Table 3 Heating Cable Specification (600V Double Conductors)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    26C3.412.90.0034150783.76
    26C4.412.20.0044160701.56
    26C5.811.30.0058170606.16
    26C8.69.900.0086180451.43
    26C11.49.300.0114200400.05
    26C13.89.000.0138210375.20
    26C17.28.600.0172220344.90
    26C238.000.023250303.25
    26C34.47.500.0344280269.20
    26C49.27.100.0492300243.84
    26K2409.900.24180451.43
    26K3209.300.32200400.05
    26K3849.000.384210375.20
    26K4808.600.48220344.90
    26K6408.000.64250303.25
    26K9607.500.96280269.20

    Table 4 Heating Cable Specification (300V Double Cores)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    23C3.412.00.0034200708.10
    23C4.411.30.0044220629.07
    23C5.810.40.0058240537.73
    23C8.69.000.0086260392.56
    23C11.48.400.0114280343.89
    23C13.88.000.0138300314.57
    23C17.27.600.0172320286.27
    23C237.100.023340252.98
    23C34.46.600.0344360221.19
    23C49.26.200.0492380197.64
    23K16010.40.16220508.37
    23K2409.000.24240392.56
    23K3208.400.32265343.89
    23K3848.000.384280314.57
    23K4807.700.48300291.91
    23K6407.100.64320252.98
    23K9606.500.96350216.11

    Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

    For the use of 660V voltage occasions, please contact our company professionals;

    Mark of (300)☆ is a recommended production length by MICH


    Selection Parameters:


    Constant Wattage Heating CableHigh Temperature Heating cablePolyamide/Fiberglass Heating CableHarsh Environment Heating CableGeneral Purpose Heating Cable
    Available Voltages120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC

    Available Wattages


    4, 8 & 12 watts/ft (13, 26 & 39 watts/m)4, 8 & 12 watts/ft (13, 26 & 39 watts/m)4, 8 & 12 watts/ft (13, 26 & 39 watts/m)3, 5, 8 & 12 watts/ft (10, 16, 26 & 39 watts/m)
    Maximum Exposure Temperature

    500°F (260°C)


    500°F (260°C)


    500°F (260°C)


    400°F (204°C)


    Nominal Dimensions


    0.2"x0.3" (5mm x 8mm) 12 AWG


    0.2"x0.3" (5mm x 8mm) 12 AWG


    0.2"x0.3" (5mm x 8mm) 12 AWG


    0.2"x0.3" (5mm x 8mm) 12 AWG
    Resistance to MoistureGoodGood

    Excellent


    Excellent


    Resistance to ChemicalsGoodGood

    Excellent


    Excellent


    Resistance to FlameExcellentOutstandingExcellentOutstanding
    Dielectric StrengthOver 2000 volts

    Over 2000 volts


    Over 2000 voltsOver 2000 volts
    Quality Anti Corrosion Pipe Tracing Heating Tape Cables For Oil Terminal for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Pasia Industries Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Electric Heat Tracing products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0