    Ask Lasest Price
    Brand Name : MICH
    Model Number : EHTSCSPS
    Certification : ISO9001
    Price : USD0.5-USD5 per meter
    Supply Ability : 10 million meters per year
    Delivery Time : in one month
    • Product Details
    • Company Profile

    Thermon Self Regulating Heat Trace For Concentrated Solar Power System

    Electric Heat Tracing Solutions for Concentrated Solar Power System is a integrated system for heat trace solution ot the Concentrated Solar Power plant for maintaining a certain temperature for the heat storage media such as molten salt, conduction oil, water etc and its supporting facilities. The heating elements can be mineral insulated cable, self-regulating cable, constant power cable etc.


    Although CSP makes solar electricity by harvesting sunlight like PV, it operates more like a conventional power plant. Once the sunlight is collected as heat, the “back end” – the power block – works the same as any other thermal energy power station.


    Coal, natural gas, and nuclear power plants all operate on thermal energy, but must burn a fuel to make electricity.


    CSP also runs on thermal energy. But instead of having to burn a fuel to generate the next few hours of electricity, CSP can harvest a pretty much endless supply of sunlight to store and deliver solar thermal energy. In contrast with a finite fuel like gas or coal or uranium that must be dug up from below the earth to use up by burning it to make electricity – this sunlight will be available above the earth for centuries.


    Because of its ability to store solar energy thermally, CSP can deliver power on demand (so it’s dispatchable), and it can be made available whenever it’s wanted. In other words, CSP is solar power that can be switched on when needed — in the evening, before sunrise, or at whatever time the regional grid needs power.


    A solar thermal power plant can respond to new demand within the same day. The speed of start-up is limited only by the time it takes to start the turbines, just as it does with other thermal power stations, about 20 minutes.


    This power block technology and the ability to store its solar energy thermally makes CSP a disruptive renewable technology. It can make the energy grid cleaner because it can actively replace fossil energy. Together with the other renewables, CSP plays a role in a cleaner new grid. So CSP does not compete with PV. It competes with natural gas.


    Cable Structure


    Specification

    Heating cable instruction code


    MI CU-B 16K320/60/2520/220/E1

    No. 1 2 3 4 5 6 7


    No.Instruction
    1Sheath materialCU
    2structure of cable componentsshown in table 1
    3cable codesshown in table 2, 3 and 4
    4length of heating cableIn meter
    5Heating cable powerIn Watt
    6heating cable voltageIn Volt
    7heating cable voltageSee table 5

    Cable Code


    1 6 K 320

    No. 1 2 3 4


    Serial NO.Instruction
    1core number1 or 2
    2Voltage grade3=300V, 6=600V
    3conductor materialsC,K
    4cold resistance ×1000320=0.32Ω/m×1000

    Table 1 Structure of Cable Element


    Note: Model C, F and G are suitable for being used at temperature under 65


    Table 2 Heating Cable Specification (600V Single Conductor)


    Cable CodeDiameterHDPE DiameterStandard resistance value at +20Maximum Production LengthUnit weight
    mmmmΩ/mmkg/km
    16C1.78.2100.0017350366.54
    16C2.27.69.40.0022380307.77
    16C2.97.08.80.0029400264.45
    16C45.97.70.004600190.88
    16C75.37.10.007600154.08
    16C114.96.70.011600132.25
    16C134.66.40.013600 (300)☆125.7
    16C174.66.40.017600 (300)☆117.16
    16C214.66.40.021600 (300)☆111.9
    16C253.75.50.025600 (480)☆68.83
    16C333.75.50.033600 (480)☆63.76
    16C403.45.20.04600 (560)☆58.87
    16C633.250.06360051.47
    16K806.88.60.08370 (140)☆254.18
    16K1005.270.1450 (240)☆162.11
    16K1404.96.70.14600 (270)☆122.55
    16K1974.456.250.197600 (330)☆111.32
    16K2204.56.30.22600 (330)☆102.89
    16K3154.36.10.315600 (350)☆91.44
    16K3454.26.00.345600 (370)☆85.9
    16K4504.05.80.45600 (400)☆80.73
    16K6304.05.80.63600 (400)☆77.26
    16K8003.55.30.8600 (530)☆61.48
    16K12502.84.61.2560040.83
    16K20002.84.62.060038.96

    Table 3 Heating Cable Specification (600V Double Conductors)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    26C3.412.90.0034150783.76
    26C4.412.20.0044160701.56
    26C5.811.30.0058170606.16
    26C8.69.900.0086180451.43
    26C11.49.300.0114200400.05
    26C13.89.000.0138210375.20
    26C17.28.600.0172220344.90
    26C238.000.023250303.25
    26C34.47.500.0344280269.20
    26C49.27.100.0492300243.84
    26K2409.900.24180451.43
    26K3209.300.32200400.05
    26K3849.000.384210375.20
    26K4808.600.48220344.90
    26K6408.000.64250303.25
    26K9607.500.96280269.20

    Table 4 Heating Cable Specification (300V Double Cores)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    23C3.412.00.0034200708.10
    23C4.411.30.0044220629.07
    23C5.810.40.0058240537.73
    23C8.69.000.0086260392.56
    23C11.48.400.0114280343.89
    23C13.88.000.0138300314.57
    23C17.27.600.0172320286.27
    23C237.100.023340252.98
    23C34.46.600.0344360221.19
    23C49.26.200.0492380197.64
    23K16010.40.16220508.37
    23K2409.000.24240392.56
    23K3208.400.32265343.89
    23K3848.000.384280314.57
    23K4807.700.48300291.91
    23K6407.100.64320252.98
    23K9606.500.96350216.11

    Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

    For the use of 660V voltage occasions, please contact our company professionals;

    Mark of (300)☆ is a recommended production length by MICH


    Table 5 terminal specifications


    Model: A, D, EModel: B
    Maximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)
    60015E220E115E1
    60020E225E220E1
    60030E340E230E2
    60050E370E250E2
    60070E3100E370E2

    Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

    Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.


    Corresponding reference table between the output power and sheath temperature


    Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.


    Anticorrosive specification


    Material

    MICU

    MIHC
    SulfateNot recommendExcellent
    Hydrochloric acidNot recommendExcellent
    Hydrofluoric acidAcceptableAcceptable
    PhosphateAcceptableAcceptable
    CarbonateNot recommendAcceptable
    Organic acidAcceptableNot recommend
    Alkali metalAcceptableAcceptable
    Sea waterNot recommendAcceptable
    ChlorideData checking requiredAcceptable

    Explosion-proof instructions


    MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.


    Quality Thermon Self Regulating Heat Trace  For Concentrated Solar Power System for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Pasia Industries Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Electric Heat Tracing products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0