    Ask Lasest Price
    Brand Name : MICH
    Model Number : EHTTSLNGI
    Certification : ISO9001
    Price : USD0.5-USD5 per meter
    Supply Ability : 10 million meters per year
    Delivery Time : in one month
    • Product Details
    • Company Profile

    39W Electric Heat Tracing For Liquefied Natural Gas Industry

    Electric Heat Tracing Technical Solution for Liquefied Natural Gas Industry heat tracing has the function of temperature control, which can self-adjust the temperature demand, that is, when the temperature is lower than the set value, the heat tracing will automatically open, and when the temperature is too high, the power supply will automatically shut down.


    Liquefied natural gas (LNG) plays a very important role in modern life. Under the condition of low temperature in winter, the liquefied condensate and water in natural gas are easy to cause freezing and blocking pipelines, which affects normal supply of natural gas to production and life.In order to alleviate the contradiction between supply and demand of natural gas, many liquefied natural gas companies use electric heat tracing products to take anti-freezing measures, which can ensure the stable supply of natural gas.


    Liquefied natural gas uses electric tracing heat preservation measures, which can be directly wound on the pipelines and valves of liquefied natural gas, and used with various accessories. Electric heat tracing can generate electricity to compensate the heat loss of the pipeline, and then wrap insulation cotton or felt to play the role of heat storage and insulation, forming a complete electric heat tracing and insulation system.
    Because liquefied natural gas belongs to explosive media and located in outdoor humid area, it is necessary to consider the problems of explosion-proof, protection and corrosion protection when choosing electric heating. Considering comprehensively, it is recommended to choose low-temperature explosion-proof anti-corrosion electric heat tracing products. This electric heat tracing can effectively eliminate static electricity and resist external machinery to touch the environment. There is also a layer of anti-corrosion coat with good protection and anti-corrosion performance.This type of electric heat tracing is mainly used in heat preservation places with explosion-proof and anti-corrosion requirements.


    Liquefied natural gas electric heat tracing is made of flame retardant materials, which has high safety. It will be more reliable with the addition of shielding layer and anticorrosive outer sheath.After electric tracing heating, the heating temperature is uniform, which reduces the probability of accident.In addition, electric heat tracing can be arbitrary shear, will not affect the use of the effect.Liquefied natural gas heat tracing can also be installed superposition, simple and convenient, easy to install and dismantle, improve the efficiency of maintenance equipment.


    Liquefied natural gas electric heating has a wide range of applications, with the characteristics of safety and reliability, environmental protection and energy saving, uniform heating, long service life, suitable for pipeline, equipment and containers of temperature control, heat tracing, heat preservation, heating.



    Table 2 Heating Cable Specification (600V Single Conductor)


    Cable CodeDiameterHDPE DiameterStandard resistance value at +20Maximum Production LengthUnit weight
    mmmmΩ/mmkg/km
    16C1.78.2100.0017350366.54
    16C2.27.69.40.0022380307.77
    16C2.97.08.80.0029400264.45
    16C45.97.70.004600190.88
    16C75.37.10.007600154.08
    16C114.96.70.011600132.25
    16C134.66.40.013600 (300)☆125.7
    16C174.66.40.017600 (300)☆117.16
    16C214.66.40.021600 (300)☆111.9
    16C253.75.50.025600 (480)☆68.83
    16C333.75.50.033600 (480)☆63.76
    16C403.45.20.04600 (560)☆58.87
    16C633.250.06360051.47
    16K806.88.60.08370 (140)☆254.18
    16K1005.270.1450 (240)☆162.11
    16K1404.96.70.14600 (270)☆122.55
    16K1974.456.250.197600 (330)☆111.32
    16K2204.56.30.22600 (330)☆102.89
    16K3154.36.10.315600 (350)☆91.44
    16K3454.26.00.345600 (370)☆85.9
    16K4504.05.80.45600 (400)☆80.73
    16K6304.05.80.63600 (400)☆77.26
    16K8003.55.30.8600 (530)☆61.48
    16K12502.84.61.2560040.83
    16K20002.84.62.060038.96

    Table 3 Heating Cable Specification (600V Double Conductors)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    26C3.412.90.0034150783.76
    26C4.412.20.0044160701.56
    26C5.811.30.0058170606.16
    26C8.69.900.0086180451.43
    26C11.49.300.0114200400.05
    26C13.89.000.0138210375.20
    26C17.28.600.0172220344.90
    26C238.000.023250303.25
    26C34.47.500.0344280269.20
    26C49.27.100.0492300243.84
    26K2409.900.24180451.43
    26K3209.300.32200400.05
    26K3849.000.384210375.20
    26K4808.600.48220344.90
    26K6408.000.64250303.25
    26K9607.500.96280269.20

    Table 4 Heating Cable Specification (300V Double Cores)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    23C3.412.00.0034200708.10
    23C4.411.30.0044220629.07
    23C5.810.40.0058240537.73
    23C8.69.000.0086260392.56
    23C11.48.400.0114280343.89
    23C13.88.000.0138300314.57
    23C17.27.600.0172320286.27
    23C237.100.023340252.98
    23C34.46.600.0344360221.19
    23C49.26.200.0492380197.64
    23K16010.40.16220508.37
    23K2409.000.24240392.56
    23K3208.400.32265343.89
    23K3848.000.384280314.57
    23K4807.700.48300291.91
    23K6407.100.64320252.98
    23K9606.500.96350216.11

    Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

    For the use of 660V voltage occasions, please contact our company professionals;

    Mark of (300)☆ is a recommended production length by MICH


    Selection Parameters:


    Constant Wattage Heating CableHigh Temperature Heating cablePolyamide/Fiberglass Heating CableHarsh Environment Heating CableGeneral Purpose Heating Cable
    Available Voltages120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC120, 208, 240, 277 & 480 VAC

    Available Wattages


    4, 8 & 12 watts/ft (13, 26 & 39 watts/m)4, 8 & 12 watts/ft (13, 26 & 39 watts/m)4, 8 & 12 watts/ft (13, 26 & 39 watts/m)3, 5, 8 & 12 watts/ft (10, 16, 26 & 39 watts/m)
    Maximum Exposure Temperature

    500°F (260°C)


    500°F (260°C)


    500°F (260°C)


    400°F (204°C)


    Nominal Dimensions


    0.2"x0.3" (5mm x 8mm) 12 AWG


    0.2"x0.3" (5mm x 8mm) 12 AWG


    0.2"x0.3" (5mm x 8mm) 12 AWG


    0.2"x0.3" (5mm x 8mm) 12 AWG
    Resistance to MoistureGoodGood

    Excellent


    Excellent


    Resistance to ChemicalsGoodGood

    Excellent


    Excellent


    Resistance to FlameExcellentOutstandingExcellentOutstanding
    Dielectric StrengthOver 2000 volts

    Over 2000 volts


    Over 2000 voltsOver 2000 volts
    Quality 39W Electric Heat Tracing For Liquefied Natural Gas Industry for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Pasia Industries Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Electric Heat Tracing products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0