Sign In | Join Free | My burrillandco.com
Home > Other Metals & Metal Products >

Mineral Insulated Electric Heat Tracing For Molten Salt

    Buy cheap Mineral Insulated Electric Heat Tracing For Molten Salt from wholesalers
     
    Buy cheap Mineral Insulated Electric Heat Tracing For Molten Salt from wholesalers
    • Buy cheap Mineral Insulated Electric Heat Tracing For Molten Salt from wholesalers
    • Buy cheap Mineral Insulated Electric Heat Tracing For Molten Salt from wholesalers

    Mineral Insulated Electric Heat Tracing For Molten Salt

    Ask Lasest Price
    Brand Name : MICH
    Model Number : MIEHTMSCSPS
    Certification : ISO9001
    Price : USD0.5-USD5 per meter
    Supply Ability : 10 million meters per year
    Delivery Time : in one month
    • Product Details
    • Company Profile

    Mineral Insulated Electric Heat Tracing For Molten Salt

    Mineral Insulated Electric Heat Trace for Molten Salt on Concentrated Solar Power System is a integrated system for heat trace solution ot the Concentrated Solar Power plant for maintaining a certain temperature for the molten salt and its supporting facilities. In the CSP system, sunrays are reflected from the heliostats to the receiver at the top of the tower. In order to transport, store and convert this solar energy to power, molten salts must be heated to 550 °C and kept at temperature to prevent them from solidifying and thus clogging. This occurs at +260 °C.


    This is why not just the molten salts, but also carrier and synthetic oils must be held at 15 °C, water above freezing and condensation avoided, too. This is where the electrical heat tracing system performs its major task. Thus, electrical heat tracing fulfils its main task: to maintain temperatures along the entire process. This applies to a wide range of facilities and installations for production, transport and storage, on pipelines, tanks and silos.


    High-temperature heat pipes are typically defined as heat pipes that operate between 400 and 1100°C. However, the fluid properties vary too much across this wide temperature range for any one of those fluids. Three fluids are typically used to cover this range; Cesium, Potassium, and Sodium. The operating range for each fluid is shown below:


    Cesium 300 to 600°C (572 to 1,112°F)

    Potassium 400 to 1000°C (752 to 1,832°F)

    Sodium 500 to 1100°C (932 to 2,012°F)


    Typical applications for high-temperature heat pipes include the following:


    1. Heat Engine Receivers (Steam, Stirling, Brayton, Rankine)

    2. Solar Thermal

    3. Heat exchangers

    4. Hypersonic wing leading edges

    5. Waste heat recovery

    6. Nuclear power

    7. Thermoelectric Generators

    8. Isothermalizing furnace elements


    Cable Structure


    Specification

    Heating cable instruction code


    MI CU-B 16K320/60/2520/220/E1

    No. 1 2 3 4 5 6 7


    No.Instruction
    1Sheath materialCU
    2structure of cable componentsshown in table 1
    3cable codesshown in table 2, 3 and 4
    4length of heating cableIn meter
    5Heating cable powerIn Watt
    6heating cable voltageIn Volt
    7heating cable voltageSee table 5

    Cable Code


    1 6 K 320

    No. 1 2 3 4


    Serial NO.Instruction
    1core number1 or 2
    2Voltage grade3=300V, 6=600V
    3conductor materialsC,K
    4cold resistance ×1000320=0.32Ω/m×1000

    Table 1 Structure of Cable Element


    Note: Model C, F and G are suitable for being used at temperature under 65


    Table 2 Heating Cable Specification (600V Single Conductor)


    Cable CodeDiameterHDPE DiameterStandard resistance value at +20Maximum Production LengthUnit weight
    mmmmΩ/mmkg/km
    16C1.78.2100.0017350366.54
    16C2.27.69.40.0022380307.77
    16C2.97.08.80.0029400264.45
    16C45.97.70.004600190.88
    16C75.37.10.007600154.08
    16C114.96.70.011600132.25
    16C134.66.40.013600 (300)☆125.7
    16C174.66.40.017600 (300)☆117.16
    16C214.66.40.021600 (300)☆111.9
    16C253.75.50.025600 (480)☆68.83
    16C333.75.50.033600 (480)☆63.76
    16C403.45.20.04600 (560)☆58.87
    16C633.250.06360051.47
    16K806.88.60.08370 (140)☆254.18
    16K1005.270.1450 (240)☆162.11
    16K1404.96.70.14600 (270)☆122.55
    16K1974.456.250.197600 (330)☆111.32
    16K2204.56.30.22600 (330)☆102.89
    16K3154.36.10.315600 (350)☆91.44
    16K3454.26.00.345600 (370)☆85.9
    16K4504.05.80.45600 (400)☆80.73
    16K6304.05.80.63600 (400)☆77.26
    16K8003.55.30.8600 (530)☆61.48
    16K12502.84.61.2560040.83
    16K20002.84.62.060038.96

    Table 3 Heating Cable Specification (600V Double Conductors)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    26C3.412.90.0034150783.76
    26C4.412.20.0044160701.56
    26C5.811.30.0058170606.16
    26C8.69.900.0086180451.43
    26C11.49.300.0114200400.05
    26C13.89.000.0138210375.20
    26C17.28.600.0172220344.90
    26C238.000.023250303.25
    26C34.47.500.0344280269.20
    26C49.27.100.0492300243.84
    26K2409.900.24180451.43
    26K3209.300.32200400.05
    26K3849.000.384210375.20
    26K4808.600.48220344.90
    26K6408.000.64250303.25
    26K9607.500.96280269.20

    Table 4 Heating Cable Specification (300V Double Cores)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    23C3.412.00.0034200708.10
    23C4.411.30.0044220629.07
    23C5.810.40.0058240537.73
    23C8.69.000.0086260392.56
    23C11.48.400.0114280343.89
    23C13.88.000.0138300314.57
    23C17.27.600.0172320286.27
    23C237.100.023340252.98
    23C34.46.600.0344360221.19
    23C49.26.200.0492380197.64
    23K16010.40.16220508.37
    23K2409.000.24240392.56
    23K3208.400.32265343.89
    23K3848.000.384280314.57
    23K4807.700.48300291.91
    23K6407.100.64320252.98
    23K9606.500.96350216.11

    Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

    For the use of 660V voltage occasions, please contact our company professionals;

    Mark of (300)☆ is a recommended production length by MICH


    Table 5 terminal specifications


    Model: A, D, EModel: B
    Maximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)
    60015E220E115E1
    60020E225E220E1
    60030E340E230E2
    60050E370E250E2
    60070E3100E370E2

    Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

    Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.


    Corresponding reference table between the output power and sheath temperature


    Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.


    Anticorrosive specification


    Material

    MICU

    MIHC
    SulfateNot recommendExcellent
    Hydrochloric acidNot recommendExcellent
    Hydrofluoric acidAcceptableAcceptable
    PhosphateAcceptableAcceptable
    CarbonateNot recommendAcceptable
    Organic acidAcceptableNot recommend
    Alkali metalAcceptableAcceptable
    Sea waterNot recommendAcceptable
    ChlorideData checking requiredAcceptable

    Explosion-proof instructions


    MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.

    Quality Mineral Insulated Electric Heat Tracing For Molten Salt for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Pasia Industries Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Electric Heat Tracing products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0