    Mineral Insulated Electrical Tracing On Pipe

    Mineral Insulated Heat Trace to Pistons, Valves, Pumps, Pipes, Pipe bends and Containers for Pharmaceutical Industry are used on the heat trace for the vessels like piston, valve, pump, pipe, bend and containers where the viscous media are stored and transported. Generally speaking, during normal production, electric heat tracing does not work. Only when the equipment is not running, the electric heat tracing system is turned on to ensure that the equipment can work normally when it is restarted.


    MI armoured heating cable is made of single or multiple alloy electric heating wire as heating source, insulated with high purity, high temperature, electric melting crystallization magnesium oxide, sheathed by seamless continuous stainless steel or copper tube and formed using special production process. Used in highly corrosive places, PE or low smoke halogen-free coat can be added.


    This heat tracing solution is suitable for explosion-proof, anti-corrosion areas, with the advantages of cost saving, environmental protection, easy installation and long service life etc.


    Cable Structure


    Specification

    Heating cable instruction code


    MI CU-B 16K320/60/2520/220/E1

    No. 1 2 3 4 5 6 7


    No.Instruction
    1Sheath materialCU
    2structure of cable componentsshown in table 1
    3cable codesshown in table 2, 3 and 4
    4length of heating cableIn meter
    5Heating cable powerIn Watt
    6heating cable voltageIn Volt
    7heating cable voltageSee table 5

    Cable Code


    1 6 K 320

    No. 1 2 3 4


    Serial NO.Instruction
    1core number1 or 2
    2Voltage grade3=300V, 6=600V
    3conductor materialsC,K
    4cold resistance ×1000320=0.32Ω/m×1000

    Table 1 Structure of Cable Element


    Note: Model C, F and G are suitable for being used at temperature under 65


    Table 2 Heating Cable Specification (600V Single Conductor)


    Cable CodeDiameterHDPE DiameterStandard resistance value at +20Maximum Production LengthUnit weight
    mmmmΩ/mmkg/km
    16C1.78.2100.0017350366.54
    16C2.27.69.40.0022380307.77
    16C2.97.08.80.0029400264.45
    16C45.97.70.004600190.88
    16C75.37.10.007600154.08
    16C114.96.70.011600132.25
    16C134.66.40.013600 (300)☆125.7
    16C174.66.40.017600 (300)☆117.16
    16C214.66.40.021600 (300)☆111.9
    16C253.75.50.025600 (480)☆68.83
    16C333.75.50.033600 (480)☆63.76
    16C403.45.20.04600 (560)☆58.87
    16C633.250.06360051.47
    16K806.88.60.08370 (140)☆254.18
    16K1005.270.1450 (240)☆162.11
    16K1404.96.70.14600 (270)☆122.55
    16K1974.456.250.197600 (330)☆111.32
    16K2204.56.30.22600 (330)☆102.89
    16K3154.36.10.315600 (350)☆91.44
    16K3454.26.00.345600 (370)☆85.9
    16K4504.05.80.45600 (400)☆80.73
    16K6304.05.80.63600 (400)☆77.26
    16K8003.55.30.8600 (530)☆61.48
    16K12502.84.61.2560040.83
    16K20002.84.62.060038.96

    Table 3 Heating Cable Specification (600V Double Conductors)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    26C3.412.90.0034150783.76
    26C4.412.20.0044160701.56
    26C5.811.30.0058170606.16
    26C8.69.900.0086180451.43
    26C11.49.300.0114200400.05
    26C13.89.000.0138210375.20
    26C17.28.600.0172220344.90
    26C238.000.023250303.25
    26C34.47.500.0344280269.20
    26C49.27.100.0492300243.84
    26K2409.900.24180451.43
    26K3209.300.32200400.05
    26K3849.000.384210375.20
    26K4808.600.48220344.90
    26K6408.000.64250303.25
    26K9607.500.96280269.20

    Table 4 Heating Cable Specification (300V Double Cores)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    23C3.412.00.0034200708.10
    23C4.411.30.0044220629.07
    23C5.810.40.0058240537.73
    23C8.69.000.0086260392.56
    23C11.48.400.0114280343.89
    23C13.88.000.0138300314.57
    23C17.27.600.0172320286.27
    23C237.100.023340252.98
    23C34.46.600.0344360221.19
    23C49.26.200.0492380197.64
    23K16010.40.16220508.37
    23K2409.000.24240392.56
    23K3208.400.32265343.89
    23K3848.000.384280314.57
    23K4807.700.48300291.91
    23K6407.100.64320252.98
    23K9606.500.96350216.11

    Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

    For the use of 660V voltage occasions, please contact our company professionals;

    Mark of (300)☆ is a recommended production length by MICH


    Table 5 terminal specifications


    Model: A, D, EModel: B
    Maximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)
    60015E220E115E1
    60020E225E220E1
    60030E340E230E2
    60050E370E250E2
    60070E3100E370E2

    Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

    Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.


    Corresponding reference table between the output power and sheath temperature


    Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.


    Quality Mineral Insulated Electrical Tracing On Pipe for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Pasia Industries Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Electric Heat Tracing products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0