Sign In | Join Free | My burrillandco.com
Home > Power Distribution Equipment >

AC220V 160kPa Wire Cable Flammability Test Chamber

    Buy cheap AC220V 160kPa Wire Cable Flammability Test Chamber from wholesalers
     
    Buy cheap AC220V 160kPa Wire Cable Flammability Test Chamber from wholesalers
    • Buy cheap AC220V 160kPa Wire Cable Flammability Test Chamber from wholesalers
    • Buy cheap AC220V 160kPa Wire Cable Flammability Test Chamber from wholesalers
    • Buy cheap AC220V 160kPa Wire Cable Flammability Test Chamber from wholesalers
    • Buy cheap AC220V 160kPa Wire Cable Flammability Test Chamber from wholesalers
    • Buy cheap AC220V 160kPa Wire Cable Flammability Test Chamber from wholesalers

    AC220V 160kPa Wire Cable Flammability Test Chamber

    Ask Lasest Price
    Brand Name : YUYANG
    Model Number : YY611
    Certification : UL1581
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 50/sets
    Delivery Time : 10-15 days
    • Product Details
    • Company Profile

    AC220V 160kPa Wire Cable Flammability Test Chamber

    UL1581 200W Wire and Cable Flame Testing Equipment 0-160kPa​

    Descriptions:

    UL1581 Wire and Cable Flame Test Chamber is used to test the flame retardant performance of insulation layer under abnormal conditions such as overheat and overcurrent.This sect will be manufactured strictly according to UL1581 sect 1080.1~1080.14 and approved by Guangzhou MEIhua UL Co., LTD., which fully meets the VW-1 Flame Test standard and is applicable to FT-1 and FT-2 of UL1581.The equipment has beautiful appearance, reasonable internal structure, simple and fast operation, accurate test. It is widely used by wire and cable manufacturers, colleges ,universities and commodity inspection departments.

    The equipment is composed of test part and control part and adopts integrated design, which is convenient for field installation and commissioning.The control system is highly automated and has the function of automatic ignition.Real-time display of temperature and time, convenient observation and recording, stable and reliable use.

    The back of the chamber body is equipped with a strong exhaust air exhaust system. After the test is completed, it is opened at the same time with air supply system to discharge waste gas to outside in time. The front of the chamber body is equipped with sealed toughened glass window and operation window, which is convenient for the observation of test process and operation of experimenter.

    Main Technical Parameters:


    Spraying time:it can be set
    Burn off time:it can be set
    The number of flame:setting
    U manometer:1M
    Pressure gauge:0-160kPa
    Power supply:AC220V, 50HZ


    Test instructions:

    1.Sample preparation for FT1 combustion test:

    One sample, about 455mm long, is taken from the finished wire and cable or flexible cord.

    2. Operation method of FT1 combustion test:

    2.1. Prepare samples and handle them according to the relevant provisions in the above "Sample Preparation".

    2.2 Open the door of test chamber, clamp both ends of sample into the upper and lower fixtures respectively and fix them.Move the flame spread limit indicator and flame spread start indicator to the appropriate position.Access gas, access air.

    2.3 Power on and turn on the power switch.Turn on "Light" on the touch screen and turn on lighting.Press the "Move fire NOZZLE" on touch screen. Tilt the nozzle 70° and place it (as shown below). Then install a flame nozzle (Long:40mm). Move the nozzle assembly appropriately and compare it to nozzle to determine the nozzle's test position.(Note: Once the position of blowtorch is determined, it does not need to be adjusted)

    2.4 After the nozzle is adjusted, remove flame nozzle and press the "Move fire NOZZLE" on touch screen. Place the nozzle perpendicular to 90°.

    2.5. Rotate the igniter so that it is above flame nozzle.Press the Ignite on touch screen and Ignite the spout.Adjust the gas flow rate, gas pressure and blowtorch fine-tuning valve on panel. Measure and adjust the flame height with flame gauge 125mm blue internal flame 40mm.

    2.6 Press the "Start" button on touch screen to start test.

    2.7. The nozzle will be automatically tilted 70° to apply flame to sample for 15 seconds, and then tilted back to vertical position for 15 seconds.Do this five times.

    2.8 After the 5th casting, observe the afterglow, and press the "Stop" button when the afterglow stops.

    2.9. Open the "Fan" and "Air Inlet" on touch screen means to open the air inlet, smoke exhaust and air inlet holes at both sides of chamber.The test is over.

    Accessories Show:

    Quality AC220V 160kPa Wire Cable Flammability Test Chamber for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN YUYANG INSTRUMENT CO., LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Flammability Testing Equipment products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0