Sign In | Join Free | My burrillandco.com
Home > Relays >

ZXDU58 W121 V4.0R01M08 For Communications Equipment

    Buy cheap ZXDU58 W121 V4.0R01M08 For Communications Equipment from wholesalers
     
    Buy cheap ZXDU58 W121 V4.0R01M08 For Communications Equipment from wholesalers
    • Buy cheap ZXDU58 W121 V4.0R01M08 For Communications Equipment from wholesalers
    • Buy cheap ZXDU58 W121 V4.0R01M08 For Communications Equipment from wholesalers
    • Buy cheap ZXDU58 W121 V4.0R01M08 For Communications Equipment from wholesalers

    ZXDU58 W121 V4.0R01M08 For Communications Equipment

    Ask Lasest Price
    Brand Name : ZTE
    Model Number : ZXDU58 W121
    Certification : CE, RoHS
    Price : negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 1000 sets/month
    Delivery Time : within 10 days of payment
    • Product Details
    • Company Profile

    ZXDU58 W121 V4.0R01M08 For Communications Equipment

    ZXDU58 W121 V4.0R01M08 ZTE Outdoor DC Power System For Communications Equipment


    System introduction


    The ZXDU58 W121 system is an outdoor DC power. It provides -53.5 V DC power for communications equipment.
    AC input mode: Three-phase five-wire (L1/L2/L3/N/PE), 220 V - 240 V (phase voltage) / 380 V - 415 V (line voltage), 50 Hz / 60 Hz.
    In full configuration, the ZXDU58 W121 system is equipped with four ZXD1500 rectifiers, which form a rated output current of 120 A.
    For the ZXDU58 W121 system appearance, see Figure 1-1.


    ZXDU58 W121 (V4.0R01M08) DC Power System3


    System features


    The ZXDU58 W121 system has the following features:
    *A wide range of input phase voltage (80 VAC - 300 VAC) makes the system suitable for areas with unstable voltage.
    *Integrating the power distribution, rectifiers, CSU and batteries in a single cabinet, and thus saving installation space.
    *The rectifier is hot-pluggable, and convenient for installation and maintenance.
    *Intelligent CSU.
    *With heat exchanger and Thermoelectric Cooler (TEC) for heat dissipation.
    *High reliability with Mean Time Between Failures (MTBF) ≥ 2.2 × 105 h.
    *Multiple networking interfaces: input relays, output relays, RS232 interfaces, and RS485 interface.


    ZXDU58 W121 (V4.0R01M08) DC Power System4


    ItemDescription
    Cabinet dimensions (H × W × D)Without thermoelectric cooler: 2200 mm × 700 mm × 700 mm
    With thermoelectric cooler: 2200 mm × 700 mm × 850 mm
    Communications equipment space19 inches in width, 14U in height (1U = 44.45 mm)
    Battery space (H × W × D)Two battery racks
    Each rack provides a net installation space of 335 mm × 537 mm × 552 mm.
    Dimension of the floor-mounting holes8–Ø16 mm

    Internal Structure


    The internal space of the ZXDU58 W121 cabinet is divided into the equipment space and the battery space.
    For the internal structure, see
    For a description of the components, refer to Figure 2-2.


    ZXDU58 W121 (V4.0R01M08) DC Power System5


    1. Heat exchanger
    2. Thermoelectric cooler
    3. Heater for battery space (optional)
    4. Battery space
    5. Power supply chassis
    6. Signal Interface Board (SIB)

    7. Communications equipment space
    8. Ventilation subrack
    9. Emergency light (optional)
    10. Smoke sensor (optional)
    11. Fan control board (FCTL)
    12. PE busbar
    13. Relay board (RLY)

    14. Environment Monitoring Board (EMB)
    15. Heater for equipment space (optional)
    16. Internal cabling holes
    17. External cabling holes
    18. Door sensor
    19. GND terminals


    Table 2-2 Component Description


    S.N.ComponentDescription
    1Heat exchangerFor heat dissipation of the equipment space
    2Thermoelectric coolerFor heat dissipation of the battery space
    3Heater for battery spaceOptional, to heat the battery space if needed
    4Battery spaceTwo battery racks. Each rack provides a net installation space of 335 mm × 537 mm × 552 mm (H × W × D)

    S.N.ComponentDescription
    5Power supply chassisProvides power input/output distribution and converts AC to DC
    For the further details, refer to 2.3 Power Supply Chassis.
    6Signal Interface Board (SIB)Provides background communication interfaces and supervision interfaces
    For the further details, refer to 2.6.1 Interface of SIB Board.
    7Communications equipment spaceInstalls the communications equipment. 19 inches in width, and 14 U in height
    8Ventilation subrackFor internal air circulation of the equipment space
    9Emergency lightOptional, for emergency lighting
    10Smoke sensorOptional, for smoke detection
    11Fan control board (FCTL)Controls the operation of the fans in the heat exchanger and the ventilation subrack
    12PE busbar-
    13Relay board (RLY)Provides eight output relaysFor the further details, refer to 2.6.2 Interface of RLY Board.
    14Environment Monitoring Board (EMB)Provides environment monitoring interfacesFor the further details, refer to 2.6.3 Interface of EMB Board.
    15Heater for equipment spaceOptionalHeats the power & communications equipment space if needed
    16Internal cabling holes-
    17External cabling holes-
    18Door sensorFor door status detection
    19GND terminals-


    Power Supply Chassis


    The power supply chassis provides power input/output distribution and converts AC to DC. For the layout of the components of the power supply chassis.


    ZXDU58 W121 (V4.0R01M08) DC Power System6

    1. AC input circuit breaker
    2. AC auxiliary output circuit breaker
    3. AC SPD
    4. DC output circuit breakers ( LLVD1)
    5. DC output circuit breakers (LLVD2)

    6. Battery input circuit breakers
    7. DC Surge Protection Device (DC SPD)
    8. Centralized Supervision Unit (CSU)
    9. ZXD1500 rectifiers


    For the internal structure of the power input/output distribution part


    ZXDU58 W121 (V4.0R01M08) DC Power System7


    For a description of the components


    S.N.ComponentDescription
    1AC input circuit breakerActivates/deactivates AC input branch
    2AC auxiliary output circuit breakerActivates/deactivates AC auxiliary input branch Reserved for the heaters for the equipment space and the battery space
    3AC SPDProvides AC input surge protection
    4DC output circuit breakers ( LLVD1)Activate/deactivate DC output (LLVD1) branches
    5DC output circuit breakers (LLVD2)Activate/deactivate DC output (LLVD2) branches
    6Battery input circuit breakersActivate/deactivate battery input branches
    7DC Surge Protection Device (DC SPD)Provides DC output surge protection
    8Centralized Supervision Unit (CSU)Monitors the ZXDU58 W121 system
    9ZXD1500 rectifiersConvert AC to DC

    2.2 ZXD1500 (V4.0) Rectifier
    The ZXD1500 (V4.0) rectifiers convert AC to DC, provide power to the loads and charge the batteries.
    Rectifier Appearance


    For the appearance of a ZXD1500 (V4.0) rectifier, see Figure 2-5.


    ZXDU58 W121 (V4.0R01M08) DC Power System8

    1. Indicators
    2. Grille

    3. Handle
    4. Stop pin

    5. Input/output integrated socket


    Indicator LabelStatus and ColorMeaning
    IN(Input )Lit (green)AC input power is normal.
    OUT(Output)Lit (green)DC output power is normal.
    CL(Current limit)Lit (yellow)Output current of the rectifier has reached its limit.
    ALM(Alarm)Lit (red)An alarm has occurred.

    ZXDU58 W121 (V4.0R01M08) DC Power System9


    Centralized Supervision Unit


    The Centralized Supervision Unit (CSU) manages the power distribution unit, rectifiers and batteries of the ZXDU58 W121 system.

    Functions
    Collects the operational data and monitors the operation of the system.
    Provides alarm and necessary protection if the system is operating abnormally.
    Sends data to the background Supervision Center (SC) and receives the commands from the SC. In this way, the system can be monitored remotely.


    ZXDU58 W121 (V4.0R01M08) DC Power System10

    1. Liquid Crystal Display (LCD)
    2. Screen
    3. Indicators

    4. Reset button
    5. Buttons
    6. Handle
    7. Power switch

    8. Fastening screw
    9. (Rear) Interface


    Indicators


    The indicators indicate the current operational status of the CSU. For a description of the CSU indicators.


    Indicator LabelStatus and ColorMeaning
    PWR PowerLit (green)Power is applied to the CSU.
    RUN RunFlashing (green)CSU is operating normally.
    EQU Charge equalizationLit (green)Battery equalized charge is in-process.
    COMM CommunicationFlashing (yellow)CSU is communicating with the connected PC.
    ALM AlarmFlashing (red)An alarm or fault has occurred.

    Buttons


    The reset button is used to restart the CSU.
    Users can perform querying and setting operations through the buttons laid on the front panel of the CSU.
    For the function description of the buttons


    Indicator LabelStatus and Color
    Turns pages (or items) upwards / increases values
    Turns pages (or items) downwards / decreases values
    EscExits and returns to the upper-level interface
    Indicator LabelStatus and Color
    EnterConfirms the current menu items/saves the current parameter setting/enters the lower-lever interface
    ▲ + EnterDisplays help information
    Product Tags:

    ZXDU58 W121

      

    V4.0R01M08

      
    Quality ZXDU58 W121 V4.0R01M08 For Communications Equipment for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Wuhan Unique Mechanical And Electrical Equipment Co.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more 5G Network Equipment products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0