Sign In | Join Free | My burrillandco.com
Home >

G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V

    Buy cheap G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V from wholesalers
     
    Buy cheap G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V from wholesalers
    • Buy cheap G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V from wholesalers
    • Buy cheap G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V from wholesalers
    • Buy cheap G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V from wholesalers
    • Buy cheap G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V from wholesalers

    G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V

    Ask Lasest Price
    Brand Name : Brando
    Model Number : ADK11-20
    Certification : CE
    Price : negotiation
    Payment Terms : L/C, T/T, Western Union,Paypal, MoneyGram
    Supply Ability : 300000 set per month
    Delivery Time : 4-8 days
    • Product Details
    • Company Profile

    G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V

    G3/4'' DN20 ADK11-20G/20A/20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V


    The ADK11-20G/20A/20N CKD Type Pilot Kick 2 Way Solenoid Valve is a direct-acting electromagnetic valve that uses the medium pressure difference to work. It adopts a diaphragm structure and has the characteristics of quick opening and closing, stable performance, convenient use, high reliability and long service life.


    The solution to the problem that the ADK11-20G/20A/20N CKD Type Pilot Kick 2 Way Solenoid Valve cannot be turned off after the power is turned off:
    (1) The solenoid valve body arrow is inconsistent with the direction of fluid flow. The detachable solenoid valve can be reinstalled so that the directions are the same;


    (2) Blockage of debris makes the valve not tight. The solenoid valve and filter should be cleaned. Under special circumstances, the pore diameter of the filter guide hole can be enlarged by about 0.1mm, and the pressure can be balanced to make the piston move normally downward and press the valve seat;


    Individual Specifications of G3/4'' ADK11-20 CKD Type Pilot Kick Type 2 Way Solenoid Valve:

    ItemPort sizeOrifice sizeMin working pressure diff.(MPa)Max working pressure diff.(MPa)Rated voltageWeight (Kg)
    Model no.AirWater, KeroseneOil(50mm²/s)
    ACDCACDCACDC
    NC (normally closed) type
    ADK11-81/4''12mm010.710.70.70.6100 VAC 50/60 Hz
    110 VAC 60 Hz
    200 VAC 50/60 Hz
    220 VAC 60 Hz
    12 VDC
    24 VDC
    48 VDC
    100 VDC
    0.65
    ADK11-103/8''12mm
    ADK11-151/2''16mm0.60.60.60.50.9
    ADK11-203/4''23mm1
    ADK11-251''28mm1.4
    NO (normally open) type
    ADK12-151/2''16mm00.60.60.60.60.50.51
    ADK12-203/4''23mm1.2
    ADK12-251''28mm1.6

    Common specifications of DN20 CKD Type ADK11-20G/20A/20N Pilot Kick 2 Way Solenoid Valve:

    ItemStandard specificationsOptional specifications
    Working fluidAir, Low Vacuum, Water, Paraffin, OilHot water
    Working pressure differential range (MPa)0 to 1.0 (refer to max. working pressure differential in individual specifications.)
    Max. working pressure (MPa)2
    Withstanding pressure (water) (MPa)4
    Fluid temperature °C-10 to 60-10 to 90
    Ambient temperature °C-10 to 60
    Heat proof classBH
    AtmospherePlace free of corrosive gas and explosive gas
    Valve structurePilot kick type poppet, diaphragm structure
    Valve seat leakage (cm³/min)1 or less (air)
    Mounting attitudeFree
    Body, sealantBronze, nitrile rubberBronze, ethylene propylene diene rubber

    Main dimension of G3/4'' ADK11-20G CKD Type Pilot Kick 2 Way Solenoid Valve:


    Materail diaplay of DN20 CKD Type ADK11-20A Pilot Kick Type 2 Way Solenoid Valve:


    Production display of CKD Type ADK11-20 Brass Body Pilot Operated Solenoid Valve:


    More details about CKD Type ADK11-25G Pilot Kick Solenoid Valve in below Youtube Video:


    Select solenoid valve according to different media:

    There are many kinds of solenoid valves, and the fluid medium is also different. It is difficult for non-professionals to distinguish. In order to facilitate the non-professionals to distinguish the fluid medium parameters of the solenoid valve, the technicians of Ningbo Bolande Hardware Co., Ltd. Introduction to media parameters:


    1. High temperature medium: The medium temperature should be selected within the allowable range of the solenoid valve. For example, hot water, steam, and heat transfer oil should be selected from high-temperature electromagnetic coils and sealing materials, and piston type types should be selected. For example, steam should be selected or stainless steel. In this case, the selection of copper is not good, because when the temperature exceeds the expansion coefficient of copper, the contradiction between the piston component of the solenoid valve and the piston cavity is contradictory, resulting in malfunction.


    2. Corrosive medium: It is recommended to use plastic king solenoid valve all stainless steel solenoid valve; for strong corrosive medium, it is necessary to use isolation diaphragm type, such as: neutral medium, copper alloy should also be used as the valve shell material solenoid valve, otherwise, There is often rust in the valve casing, especially in occasions where movement is not frequent. Ammonia valves cannot be made of copper. For the production of wine and milk process pipes, food grade stainless steel solenoid valves are used.


    3. Media cleanliness: If the medium contains a small amount of tiny impurities, the diaphragm structure may be selected, but if the impurities are large and large, the filter should be installed in front of the solenoid valve.


    4. Medium viscosity: Usually it can be arbitrarily selected below. If it exceeds this value, high viscosity solenoid valve should be used.


    5. Medium state: There are roughly gaseous, liquid or mixed states. Different types of solenoid valves should be used for this purpose, that is, for gas or liquid for different media. The medium should be noted, otherwise it is not conducive to the stable performance of the valve.


    Welcome to your question and inquiry!

    Quality G3/4'' DN20 ADK11-20G / 20A / 20N CKD Type Pilot Kick 2 Way Brass Solenoid Valve DC24V AC220V for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Ningbo Brando Hardware Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Brass Solenoid Valve products from this supplier
    Inquiry Cart 0