    Single Safety One Endo Rotary Files 3.0 N / CM Torque For Root Canal Preparation

    Ask Lasest Price
    Brand Name : Feihuan
    Model Number : Single File
    Certification : CE/ISO/FDA/FSC
    Price : negotiatable
    Payment Terms : T/T, MoneyGram, Western Union
    Supply Ability : 500,000pcs per month
    Delivery Time : 10-15 working days after received the payment
    • Product Details
    • Company Profile

    Single Safety One Endo Rotary Files 3.0 N / CM Torque For Root Canal Preparation

    Single Use File One File Gold For Root Canal Treatment Assorted Size 25 ISO Red

    Taper

    .06


    Torque3.0 N/CM
    Rotary Speed Range250-350 RMP
    Size#25
    ISO ColorRed
    Using TimesGenerally difficult root canals10-15 times
    Moderately difficult root canals8-10 times
    Difficult root canals1-2 times
    Cross SectionGradient cross sections: Triangle, Irregular shape,S-shape

    Description:

    Operation Sequence:

    1. Open the crown: Taking X-ray film before operation, dissecting shape of root canal , evaluating working length, open the crown to establish straight pathway for dental treatment.

    2. Smooth the root canal: Using 10 # K file directly determination the root length if it could, and then preparation to WL smoothly with hand file 15 # .

    3. Root canal preparation: Flushing the canal with sodium hypochlorite then use EDTA to preparation:


    (1) Using One file preparation of 2/3 canal apical narrow area, slightly pull up and down. After that exploration by using 10 # K file .

    (2) Using One file preparation of -3mm part apical narrow area , preparation without pressure,then exploration by using of 10 # file .

    1. Access Cavity Preparation

    a) Take a preoperative radiograph to assess canal anatomy and establish Estimated Working Length (EWL)

    b) Establish straight-line access preparation to expose canal orifices.

    c) Remove coronal constrictions with burs(or use current flaring technique). Canal penetration of burs is limited to 3mm below the pulp chamber floor.

    d) Irrigate thoroughly with sodium hypochlorite.


    2. Establishing the Glide Path

    Prepare the glide path using #10 Stainless Steel K-type hand file. (for example MMC 10)

    If the #10 K file easily reaches the EWL and if it is possible to take a #15 K file down to this EWL: Copiously irrigate the canal and use Mono file according to the established protocol.


    3. Shaping the Root Canal

    Irrigate thoroughly with sodium hypochlorite.

    Place One file down to the 2/3 of the WL using an in and out movement without pressure. Perform an upward circumferential filing movement in order to pre-enlarge the canal.

    Withdraw the One file instrument into the root canal and clean it. Irrigate and check canal patency with a #10 K file.

    Reintroduce the One file instrument into the root canal and place it dowm to 3mm from WL using an in and out movement without pressure.

    Withdraw the One file instrument into the root canal and clean it. Irrigate and re-check canal patency with a #10 K file.

    Reintroduce the One file instrument into the root canal and take it dowm to the WL by performing the recommended in and out movement.

    The WL can be reached in one or more passages(file withdrawal, cleaning of the file, irrigation and patency check) depending on the complexity of the canal anatomy. An upward circumferential filing movement can then be performed if necessary and according to the root canal anatomy.

    Remove and clean the instrument and irrigate the canal when apical resistance or a slight apical pull is encountered Repeat steps until the WL is reached.

    Quality Single Safety One Endo Rotary Files 3.0 N / CM Torque For Root Canal Preparation for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Feihuan Medical Instruments Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Endo Rotary Files products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0