Sign In | Join Free | My burrillandco.com
Home > Egg Boilers >

Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy

    Buy cheap Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy from wholesalers
     
    Buy cheap Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy from wholesalers
    • Buy cheap Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy from wholesalers
    • Buy cheap Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy from wholesalers
    • Buy cheap Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy from wholesalers
    • Buy cheap Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy from wholesalers

    Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy

    Ask Lasest Price
    Brand Name : iqualitrol
    Model Number : QTS-80-3
    Certification :
    Price :
    Delivery Time : 30 Working Days
    Payment Terms : T/T
    Supply Ability : 5 Sets per Month
    • Product Details
    • Company Profile

    Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy


    Cold , heat and ambient test, Thermal Shock Test Chamber with high accuracy


    Brief Introduction:

    Air-to-air thermal shock chambers circulate cold, hot, or ambient air as needed. The conditioned air is pre-cooled or pre-heated beyond the set point, allowing quicker recovery of the desired condition after transfer


    Features:

    1. Automatically setting of pro-cooled and pre-heated air.

    2.Testing samples don’t move, cable port is available for power on testing.


    3.Powerful interactive touch screen controller, easy operation and setting


    4.High accurate temperature recovery with PID auto tuning

    5.Auto defrost function


    Testing Standards:

    MIL-STD-883E Method 1011.9 Thermal Shock

    MIL-STD-202G Method 107G thermal Shock

    JIS C 0025 Change of temperature

    IEC 61300-2-47 Tests-Thermal Shocks

    JESD22-A104C Temperature cycling

    GB/T 2423.22-2012 Test N: Change of temperature


    Model Selection:

    ModelTEMP. RANGE

    interior dimensions

    (W ×H × D)cm

    Exterior dimensions

    (W ×H × D)cm

    QTS-80-3-40~150℃50*40*40145*195*155
    QTS-150-360*50*50155*205*165
    QTS-225-370*50*60175*205*185
    QTT-80-3-65~150℃50*40*40145*195*155
    QTT-150-360*50*50155*205*165
    QTT-225-370*50*60175*205*185

    Note:
    Two-zone are the same size as the three; accept the above standard specifications,support customer purchase non-standard machine.



    Technical Specifications:

    StructurePre-cooling Zone, Pre-heating Zone, Testing Zone (Selectable 2-Zone or 3-Zone Test for stationary object test)
    Damper DeviceForced Air Damper
    Interior MaterialSUS#304 Stainless Steel
    Exterior Materialstainless steel with environmentally baking paint
    Testing ShelvesStainless Steel Plate
    RefrigerationCascade Refrigeration System
    Cooling MethodWater/Air Cooling
    Ambient Temperature5℃~30℃
    Pre-heating Temperature80℃~200℃
    Pre-cooling Temperature-40℃ (-60℃/-75℃)~-10℃
    High Temp. Shocking60℃~150℃
    Low Temp. Shocking

    A=―35℃~0℃

    B=―55℃~10℃

    C=―65℃~10℃

    Temp. UniformityLess than ±2℃
    Transition time<10 seconds
    High Temp. Recovery timeRT℃~150℃/5min
    Low Temp. Recovery timeRT℃~-75℃/5min
    Pre-heating Time35min
    Pre-cooling Time85min
    ControllerPowerful interactive LCD touch screen controller
    Setting Range

    Temperature: -200℃~300℃

    Time: 0H1m~9999H59m

    Cycle: 1~9999cycle

    Resolution

    Temperature: 0.01℃

    Time: 1min

    Control MethodPID+SSR
    Power supplyAC380V/50Hz/3P
    Accessories

    Viewing Window, Cable Port, Chamber Illumination,

    LCD touch screen controller, Power cable

    Security SystemOverheat Protector, Compressor overload protector, Controller protector, Motor overload protector

    Test conditions:

    1. Ambient temperature of +23℃ and a cooling water temperature of +25℃

    2. During pre-heating, prevention for temperature heat-up may be worked

    3. Performance shown above conforms to IEC61300-2-47

    4. Temperature heat-up/pull-down time is applicable only during independent chamber operation.


    Quality Cold , Heat And Ambient Thermal Shock Test Chamber QTS-80-3 With High Accuracy for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: DongGuan Q1-Test Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Temperature Humidity Chamber products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0