Sign In | Join Free | My burrillandco.com
Home > Energy Saving Equipment Parts >

ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler

    Buy cheap ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler from wholesalers
     
    Buy cheap ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler from wholesalers
    • Buy cheap ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler from wholesalers
    • Buy cheap ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler from wholesalers
    • Buy cheap ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler from wholesalers
    • Buy cheap ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler from wholesalers

    ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler

    Ask Lasest Price
    Brand Name : HD Boiler
    Model Number : Boiler Manifold Headers
    Certification : ASME, EN, ISO,SGS
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 1set/month
    Delivery Time : 30 working days
    • Product Details
    • Company Profile

    ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler


    ISO Certification Boiler Manifold Headers For Heat Exchange , ASME


    Function

    The collecting box is the pipe fitting for boiler working medium mixing and ensuring uniform heating of working medium.Industrial boiler furnace wall is usually composed of rows and rows of tubes (water wall) together, but boiler huge volume, complicated structure, cannot guarantee that all the working medium in the pipe of heat absorption capacity is the same, different parts of heat absorption differs a lot, install header can let each pipe working medium inside converge here, the redistribution to the next level in the tube, so that we can reduce the thermal deviation, make the working medium heat, cooling flow, boiler, the boiler thermal efficiency are optimized to improve;In addition, the size, number and layout of the upper, middle and lower sections of the boiler pipes are different.


    In order to improve the efficiency of the boiler, the tube boiler was developed to increase the heat transfer area.The pot water flows into the lower box from the pot drum through the descending tube, and is distributed to each tube bundle by the box. The water in the tube bundle continuously absorbs heat energy, and is collected in the box above and then flows back into the pot drum.We call the top and bottom boxes collection boxes or header boxes.Header (also known as header), is an important part of the boiler, divided into upper header and lower header.


    Product Description
    The headers of boilers include water-cooling hinders of boilers proper, economizer hinders, superheater hinders, etc. They function for gathering, mixing and redistribution in boiler systems. In structure, they include end cover hinders or necking hinders.
    1Headers form an important part of all types of boilers.
    2Steam from the generating tubes is collected in headers which are therefore always under pressure.
    3This pressure may vary from 300 psi to 2000 psi. Since headers are always under pressure, the utmost care is taken by us while fabricating them.
    4Depending on the generating capacity of the boiler the header sizes fabricated by us vary from 100 mm to 600 mm NB. The stubs of various sizes are very carefully welded to the main body of the header to provide the desired openings from the header.


    Details


    The pressures and temperatures that headers have to withstand depend on the component to which they are connected. A header connected to an economizer or to water wall panels is subject to less severe requirements on the material than a header connected to superheaters or reheaters.


    Depending on the temperature and pressure of headers, Vallourec supplies tubes in carbon steel to high-alloy ferritic steels such as T/P91 or T/P92, with sizes ranging from 88.9 mm to 406.4 mm.


    Application

    Steam distribution headers are fabricated out of carbon steel or alloy steel seamless tubes. Customized or tailor made items are offered. Headers, after fabrication, are stress relieved to make the Steam distribution headers free from stresses. They are big pipe headers that transfer water from the downcomers to the risers through a combustion zone where the water gets partially heated to steam from the heat of fuel combustion.



    Quality ISO Certification Boiler Manifold Headers For Heat Exchange , ASME Header In Boiler for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Zhangjiagang HuaDong Boiler Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Boiler Manifold Headers products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0