| Sign In | Join Free | My burrillandco.com | 
 | 
| Ask Lasest Price | |
| Brand Name : | TOKEN | 
| Model Number : | TBC-HXS5 | 
| Certification : | CE;ROHS | 
| Price : | Price Reconsideration | 
| Supply Ability : | 2.2K pcs per month | 
Multi Range Closed Loop Hall Effect Current Sensor Precision
Current Transducer
TBC-HXS5 series multi range current sensor is a closed loop device
based on the principle of the hall effect, with a galvanic
isolation between primary and secondary circuit, it provides
accurate electronic measurement of DC, AC or pulsed currents.
| Electrical data(Ta=25℃±5℃) | 
| Type Parameter | TBC10HXS5 | TBC20HXS5 | TBC30HXS5 | TBC50HXS5 | 
 | 
| Rated input(Ipn) | 10 | 20 | 30 | 50 | A | 
| Measuringrange(Ip) | 30 | 60 | 90 | 150 | A | 
| Secondary Turns(Ns) | 1600±2 | 1600±2 | 1200±1 | 1000±1 | T | 
| Internal measuring resister | 100±0.1% | 50±0.1% | 25±0.1% | 12.5±0.1% | Ω | 
| Rated output voltage | 0.625±0.5% | 0.625±0.5% | 0.625±0.5% | 0.625±0.5% | V | 
| Supply voltage | +5±5% | V | |||
| Power consumption | 20+Ip/Ns | mA | |||
| Reference voltage | +2.5±0.4% | V | |||
| Zero voltage | @ Ip=0 2.5±0.4% | V | |||
| Offset voltage drift | @ -40~+85℃ ≤±0.5 | mV/℃ | |||
| Linearity | @ Ip=0-±Ipn ≤0.1 | %FS | |||
| Magnetic offset voltage | @Ip=3XIpn-0 ≤±0.5 | %Ipn | |||
| di/dt accurately followed | >50 | A/µS | |||
| Response time | @100A/μS,10%-90% ≤500 | nS | |||
| Bandwidth | @ -1db DC~100 | KHZ | |||
| Galvanic isolation | @ 50/60HZ,1min 2.5 | KV | |||
| Applications | 
Variable speed drives
Welding machine
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Electrochemical
| Mechanical dimension(for reference only) | 

Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm
| Pin connections | 
| Item | Turns | N(A) | Vout(V) Rated putout Voltage | [mΩ] | [uH] | Connect point | 
| Single Phase | 1 | ±10(±20,±30,±50) | 2.5±0.625±0.5% | 0.05 | 0.025 |  | 
| 2 | ±5(±10,±15,±25) | 2.5±0.625±0.5% | 0.20 | 0.1 |  | |
| 3 | ±2.5(±5,±7.5,±12.5) | 2.5±0.625±0.5% | 1.00 | 0.4 |  | 
| Directions for use | 
When the current will be measured goes through a sensor ,the
voltage will be measured at the output end.
(Note: The false wiring may result in the damage of the sensor).
Custom design in the different rated input current and the output
voltage available.
| Standards | 
| General date | 
| Value | Unit | Symbol | |
| Operating temperature | -40 to +85 | ºC | TA | 
| Storage temperature | -40 to +125 | ºC | TS | 
| Mass(approx) | 7 | g | M | 
| Characteristics chart | 
Pulse current signal response characteristic Effects of impulse
noise

|   | 
 
                                 
                                 
                                 
                                