Quaternary Pump HPLC Cromatografía with UV Detector High
Performance Liquid Chromatography Instrument
Introduction of Liquid Chromatography Instrument
High Performance Liquid Chromatography (HPLC) is a form of column chromatography that pumps a sample mixture or analyte in a solvent (known as the mobile phase) at high pressure through a column with chromatographic packing material (stationary phase). HPLC has the ability to separate, and identify compounds that are present in any sample that can be dissolved in a liquid in trace concentrations as low as parts per trillion.
Parameters of Liquid Chromatography Instrument
| Quaternary Pump HPLC Cromatografía with UV Detector High Performance Liquid Chromatography Instrument | |
| Pump | |
| Gradient | Quadratic Low Pressure | 
| Flow Rate Range | 0-11.0000mL/min | 
| Min Injection Unit | 0.0001mL/min | 
| Flow Rate Error | ±0.2% | 
| Flow Rate Repeatability | ≤ 0.08% RSD | 
| Gradient Stability | < 0.5% RSD | 
| Max Operating Pressure | 42MPa | 
| In-line Degassing | |
| Column Oven | |
| Temperature Range | 4 ℃ ~ 85 ℃ | 
| Temperature Stability | ≤±0.02 ℃ | 
| Autosampler | |
| Sampling Volume | 0.1-20.0uL (in 0.1μL increments) | 
| Sample Capacity | 120 vials, 2ml vial | 
| Linearity | r > 0.9999 | 
| Cross-contamination | < 0.002% | 
| Sampling Error | ±0.2μL (sampling volume 10μL) | 
| Sampling Repeatability | < 0.3% RSD | 
| Injection Speed | 15s | 
| UV Detector | |
| Wavelength Range | 188 - 900 nm | 
| Wavelength Error | ≤ ±0.5 nm | 
| Wavelength Repeatability | ≤ ±0.1 nm | 
| Baseline Noise | 0.8 × 10-5 AU | 
| Drift | 1.0 × 10-4 AU/h | 
| Linearity | 2.5 AU | 
Features of Liquid Chromatography Instrument
1. Two optional modes: binary high pressure and quaternary low
pressure. The binary high pressure mode is equipped with a solvent
selector valve, which can be extended from binary to quaternary
system, greatly improving the flexibility of system configuration.
2. Wavelength scaning: the absorption spectrum can be scanned in the entire range of the light source.
3. A variety of detectors available, such as DAD, ELSD and FLD.
4. Dual-wavelength detection, two wavelengths canbe detected at the same time.
|   | 