    Brand Name : HUATEC
    Model Number : HXRF-QP880
    Certification : ISO, CE, GOST
    Supply Ability : 100pcs per month
    • Product Details
    • Company Profile

    Cmos Signal 220V Ccd Spectrometer , Optical Emission Spectrometer

    CMOS Signal CCD Spectrometer Optical Emission Spectrometer Optical Emission Spectrometer


    1. Instrument Overview

    HXRF-QP880 Full Spectrum Optical Emission Spectrometer adopts the international standard of design and manufacturing technology. It uses the most advanced CMOS signal acquisition device from Japan Hamamatsu Co. Each CMOS can set the number of sparks separately. It adopts vacuum light chamber design and full digital excitation light source..This CMOS Spectrometer is not only contain the feature of full spectrum of CCD spectrometer but also have the advantages of PMT spectrometer which has very low detection limit for nonmetallic elements. The design of the whole machine is reasonable. It also has many advantages such as easy operation, high accuracy test result, long-term stability etc.

    1) Main Technical Parameters

    Application FieldMetallurgy, foundry, machinery, scientific research, commodity inspection, automobile, petrochemical, shipbuilding, electric power, aviation, nuclear power, metal and nonferrous metal smelting, processing and recovery industry.
    Analysis MatrixFe, Al, Cu, Zn, Ni, Mg, Pb etc.
    Optical SystemPara-Runge-Roland Circular Full-Spectral vacuum optical system
    Wavelength Range160~580nm
    Grating Focal Length401mm
    DetectorHigh performance CMOS array
    Light Source TypeDigital light source. High energy precombustion technology.
    Discharge Frequency100-1000Hz
    Discharge CurrentMax 400A
    Working PowerAC220V 50/60Hz 1200W
    Analysis TimeAccording to the sample type, normally is about 20s.
    Electrode TypeTungsten Spray Electrode
    Analytical Gap4mm
    Other FunctionsTemperature, software automatic control pressure, communication monitoring.

    2) Main Technical Features

    High Performance Optical SystemThe arc flame generated by the excitation of optical system is directly introduced into the vacuum optical chamber by the lens which realizes the optical path through and effectively reduces the loss of the optical path.
    High precision CMOS detector can accurately measure the nonmetallic elements such as C, P, S, As, B, N and all kinds of metal elements.
    The test results are accurate, reproducible and long-term stable.
    Automatic Optical Path CalibrationAutomatic optical path calibration. Optical system automatic spectral line scanning to ensure the correctness of the receiving and eliminating the tedious peak scanning work.
    The instrument automatically identifies a particular spectral line and compares it with the original storage line, determines the drift position, and finds out the current pixel position of the analytical line for measurement.
    Design of Plugged LensThe vacuum optical system adopts unique incident window and vacuum isolation which can be operated in the working state of the vacuum system. The optical lens adopts a plugged lens structure which is convenient for daily cleaning and maintenance.
    Open Spark TableThe flexible sample clamp design of the open spark table is designed to meet the sample analysis for various shapes and sizes at the customer site.
    The minimum analysis of the wire can reach 3mm using a small sample clamp.
    Jet Electrode TechnologyUsing the most advanced spray electrode technology in the world and using tungsten electrode. Argon jet flow will be formed around the electrode under the excited state. So the excitation point will not be in contact with the outside air during the excitation process and the excitation accuracy will be improved.
    By a unique argon gas design, greatly reduce the amount of argon gas consumption and save the customer’s cost.
    Integrated Gas Path ModuleThe air path system adopts the free maintenance design of the gas path module instead of the solenoid valve and the flow meter. The self-blowing function of the electrode creates a good environment for the excitation.
    Digital Excitation Light SourceDigital excitation light source adopts the most advanced plasma excitation light source in the world. The super stable energy is released in argon environment to stimulate the sample.
    The full digital excitation pulse is used to ensure the ultra-high resolution and high stability output of the sample plasma.
    The parameters of the light source can be adjusted arbitrarily to meet the excitation requirements of various materials.
    High-speed Data AcquisitionThe instrument adopts high performance CMOS detector and each CMOS has the function of collecting and analyzing the data. It can automatically monitor and control the operating state of the modules such as temperature, vacuum, argon pressure, light source, excitation chamber etc.
    Ethernet Data TransmissionThe Ethernet card and TCP/IP protocol are used between the computer and the spectrometer to avoid the disadvantages of electromagnetic interference and optical fiber aging. At the same time, the computer and printer are completely external which is convenient to upgrade and replace.
    Remotely monitor the instrument status, multi-channel control system and monitor all instrument parameters.
    Prefabricated Working CurveWith different materials and grades of the standard library, the factory prefabricated work curve before delivery which is convenient for installation and commissioning in order to timely production.
    The analysis program will be different according to the metals and elements. The excitation and test parameter of the instrument has been adjusted well before delivery. According to the analysis program, the optimal test condition can be automatically selected.
    The scope of analysis is attached to the specification and can be freely drawn or extended according to the standard sample supplied by the user.
    Fast Analysis SpeedThe analysis speed is very fast. It only takes 20s for one test.
    According to different analysis materials, by setting pre-burning time and measuring time, the instrument can achieve the best analysis effect with the shortest time.
    Multi-matrix AnalysisThe optical path design adopts a compass structure. The detectors are arranged alternately up and down so that all the spectral lines are received. Even though the hardware facilities are not added, the multi - matrix analysis can be realized.
    It’s easy to add matrix, material types and analytical elements without hardware cost according to production requirements.
    Chinese-English Language Software SystemThe instrument operation software is completely compatible with Windows7/8/10 system.
    The software is easy to operate even if no spectrometer knowledge and operational experience. Only after simple knowledge of training can be used.
    2. Technical Configuration

    1) Specifications and Technical Parameters

    Item

    Index

    Analysis MatrixFe, Al, Cu, Zn, Ni, Pb, Mg etc.
    Analysis TimeAccording to the sample type, normally is 20s.
    Optical SystemPara-Runge
    Wavelength Range160~580nm
    Working Power(220±20)V AC,(50±1)Hz,Single-phase power supply with protective grounding.
    Working Temperature(10~30)℃
    Storage Temperature(0~45)℃
    Working Humidity20%~80%
    Argon Gas Purity Requirement99.999%
    Argon Gas Inlet Pressure0.5MPa
    Argon Gas Flow MeterExcitation flow rate 3.5L/min,Maintain flow rate 0.4L/min,Standby flow rate 0.1L/min.
    Maximum Excitation Power400VA
    Standby Average Power100VA
    Light Source TypePulse synthesis all digital light source (programmable pulse all digital light source)
    Discharge FrequencyMax 1000 Hz
    Discharge CurrentMax 400A
    Ignition Pulse1~14kV
    Spark Excitation Pulse20~230V
    Arc Excitation pulse20~60V
    Spark Table Hole Diameter13mm

    2) Optical System

    • Full spectrum optical system with lpa-Runge structure
    • Wavelength Range: 160~580nm
    • Multiple high performance CMOS detectors
    • Resistance to environmental temperature change
    • Integrated optical chamber design, CMOS detector ensures short wave to achieve the best performance.
    • Constant temperature control of optical roon temperature is 36

    3) Sample Spark Table

    • The special design of the excitation chamber makes the cleaning of the sample excitation chamber more convenient.
    • The optimized argon gas path is designed to ensure the effective cooling of the firing station and the effective entry of metal dust into the filter during the excitation process which makes the sample excitation more stable and greatly reduces the intake of metal dust by the human body. It’s for protect the health and safety of operators.
    • Smaller excitation space which makes less argon consumption.
    • Sample fixture which is easy to use.
    • The electrode has the function of self-blowing which makes the life of electrode longer and much easier to clean the electrode.
    • The size of 13mm excited pore is more favorable for sample analysis.
    • The open sample generator can be used for the analysis of samples of various sizes and shapes.
    • The design of lens structure makes the lens disassembling and wiping more convenient and argon washing design can prolong the lens cleaning cycle.

    4) Digital Light Source

    • Pulse synthesis full digital light source (programmable pulse full digital light source). The highest frequency up to 1000 Hz.
    • High energy pre-combustion technology
    • Optimal design of control and power circuit and perfect excitation safety protection function.
    • Provide optimal spark, arc or combination excitation waveform for different analysis samples.
    • Frequency:(100~1000)Hz
    • Discharge Current:max 400 A

    5) Data Acquisition System

    • High performance DSP processor with ultra-high speed data acquisition and control function.
    • Single spark acquisition and spectral delay acquisition to achieve more optimized element content measurement.
    • External computer (user optional)
    • High speed Ethernet data transmission

    6) Analysis Software

    • Graphical Analysis Software based on Windows operating system, convenient and practical.
    • Complete automatic system diagnosis function.
    • Perfect database management function, easy to query and summarize data.
    • Intelligent correction algorithm to ensure the stability and reliability of the instrument.
    • Complete spectral line information and interference deduction algorithm to ensure analysis more accurate.
    • Adapting to the latest Windows operating system.

    7) Main Core Components list and Origin

    No.NameBrandOrigin
    1CMOS ArrayHAMAMATSUJapan
    2GratingZeissGermany
    3Optical GlassesZeissGermany
    4Optical FiberAgilentChina
    5SlitlenoxlaserChina
    6FilterTDKJapan
    7Pressure SensorSSIChina
    8Valve BlockAirtacTaiwan
    9Digital Light Source ModularHUATECHUATEC
    10Master Control and Data AcquisitionHUATECHUATEC
    11Vacuum Optical SystemHUATECHUATEC
    12Firing Station ModuleHUATECHUATEC
    13System SoftwareHUATECHUATEC
    14ComputerLenovoChina
    15PrinterHPChina
    16Standard SamplesNational StandardChina or Foreign brand

    3. Analysis Elements and Range

    ProgramFe-Low alloyFe-Cr-Ni steelFe-Cr steel
    ElementsMinMaxMinMaxMinMax
    C0.00061.30.0082.50.042.2
    Si0.013.90.0940.11.4
    Mn0.032.10.12160.11.5
    P0.0020.120.0030.30.0060.05
    S0.0020.160.0010.40.0010.3
    Cr0.014.57.4327.824
    Ni0.0044.40.8480.094.2
    Mo0.00041.30.084.20.021
    Al0.0031.50.0051.70.11.7
    Cu0.00020.50.054.50.020.5
    Co0.0010.50.008170.010.5
    Ti0.0021.20.0051.10.0060.4
    Nb0.0020.30.022  
    V0.00030.90.029.50.031.1
    W0.032.10.0024.10.050.7
    Pb0.00030.030.00010.02  
    B0.00060.020.00070.02  
    Sn0.0010.090.00030.05  
    Zn0.0020.040.0060.008  
    As0.00070.10.00040.04  
    Bi0.00010.010.000040.003  
    Zr0.0040.35    
    Ca0.00040.0020.00030.001  
    Sb0.00020.020.00050.022  
    N0.0020.090.0040.9  
    FeMatrixMatrixMatrix

    ProgramFe-Cast ironFe-Cr-hard castFe-Mn steelFe-Tool steel
    ElementsMinMaxMinMaxMinMaxMinMax
    C1.84.50.93.40.52.40.082.2
    Si0.24.70.22.50.31.70.041.5
    Mn0.064.70.12.45.3230.041.7
    P0.020.80.010.30.010.20.0040.07
    S0.0030.20.010.150.0060.110.0010.06
    Cr0.0310.50.4340.083.81.814
    Ni0.056.80.05320.043.50.070.55
    Mo0.012.10.140.120.029.4
    Al0.0020.12  0.0080.120.0051.6
    Cu0.062.20.061.50.020.60.040.5
    Co0.0080.03  0.0070.10.0088
    Ti0.00710.010.140.0040.4  
    Nb0.0020.70.10.70.080.42  
    V0.010.70.021.20.010.840.032.5
    W0.0071    0.0619
    Pb0.00020.04    0.00010.07
    Mg0.0010.14      
    B0.0020.5  0.00090.02  
    Sn0.0030.3  0.0080.070.0070.05
    La0.0020.12
    Ce0.0040.09
    N    0.010.090.0080.05
    Te0.0140.016      
    FeMatrixMatrixMatrixMatrix

    ProgramAl-Si alloyAl-Zn alloyAl-Cu alloyAl-Mg alloyPure-Al alloy
    ElementsMinMaxMinMaxMinMaxMinMaxMinMax
    Si0.02240.029.40.0270.022.30.011.2
    Fe0.0240.0310.051.90.070.80.014
    Cu0.00560.014.30.01130.00710.0021
    Mn0.00510.0210.0510.032.40.0011
    Mg0.011.50.0140.012.70.00610.20.0021
    Cr0.0050.50.010.40.010.140.010.40.0010.15
    Ni0.022.50.010.20.012.30.0050.250.0010.16
    Zn0.0053.50.01120.053.50.0110.0020.5
    Ti0.0050.40.0050.30.0010.20.0070.30.0010.15
    Be0.0010.2    0.0010.009  
    Bi0.020.60.0020.60.020.60.020.60.020.6
    Ca0.0020.03        
    Cd0.0010.30.0020.30.010.30.010.30.0010.3
    Ce      0.050.30.050.3
    Co0.0030.40.010.050.030.40.030.40.0090.4
    Ga0.0050.2    0.0090.020.0020.06
    La      0.020.120.020.12
    Pb0.0050.50.0050.50.010.50.0010.50.0020.5
    Sb0.0050.4  0.10.4    
    Sn0.0030.50.0050.20.020.30.00070.20.010.2
    Sr0.0050.1        
    V0.0050.20.0050.030.010.030.0020.030.0040.05
    Zr0.0050.20.010.30.0010.20.0030.120.0010.12
    Pr      0.0050.030.0050.03
    Nd      0.020.120.020.12
    Sm      0.0010.0060.0010.006
    P0.0020.005        
    AlMatrixMatrixMatrixMatrixMatrix

    ProgramBrassCopper-nickel-ZnAluminum BronzeTin-lead Bronze
    ElementsMinMaxMinMaxMinMaxMinMax
    Zn0.5450.010.80.0470.00311.3
    Zn  1833.5    
    Pb0.0160.0021.30.0020.120.00121
    Sn0.0099.50.0095.80.0032.50.00519
    P0.0020.20.0030.070.0020.20.0011
    Mn0.0015.30.00091.80.0012.40.0010.4
    Fe0.0230.032.70.00560.0031
    Ni0.0091.85.5340.00260.0015
    Si0.0014.60.00090.80.0040.30.0021.4
    Mg0.0010.010.0030.7    
    Cr0.0010.20.00031.8    
    Te        
    As0.0010.20.0030.050.0010.030.0040.2
    Sb0.0010.4  0.0010.10.0010.6
    Cd0.0010.02  0.0010.01  
    Bi0.0025.50.0010.10.0020.120.0061
    Ag0.0070.10.0020.1  0.0010.06
    Be        
    Co0.0040.50.0070.3  0.0010.2
    Al0.0016.70.000923.0120.010.6
    S0.0010.150.00040.08  0.0010.5
    B0.0020.0050.0030.009    
    Ti  0.0030.15    
    Se0.0031.4    0.0050.5
    CuMatrixMatrixMatrixMatrix

    ProgramRed CopperBe-BronzeSi-Bronze
    ElementsMinMaxMinMaxMinMax
    Zn0.0010.30.0050.230.26
    Zn      
    Pb0.0011.50.0050.30.010.8
    Sn0.0010.30.0050.180.050.7
    P0.0010.02  0.0050.08
    Mn0.00010.10.0050.080.21.8
    Fe0.0010.20.020.280.11.7
    Ni0.0010.50.0050.350.051
    Si  0.020.31.55
    Mg0.0010.01  0.0020.01
    Cr0.0010.030.0020.006  
    Te0.0050.05    
    As0.0050.3  0.0050.08
    Sb0.0050.35  0.0050.07
    Cd0.0010.03    
    Bi0.0010.07  0.0020.02
    Ag0.0060.05    
    Be  0.323.2  
    Co0.0010.050.152  
    Al0.0020.020.020.20.020.35
    S0.0010.05  0.0050.02
    B0.0010.03    
    Se0.0010.06    
    CuMatrixMatrixMatrix

    Note:

    • This program sheet is filled out according to the actual contract requirement of the customer.
    • If customers have standard sample requirements, provide sample numbers and purchase by themselves. If sales personnel buy it, the standard samples will be shipped separately from Wuxi.
    • If the customer uses is special application and is willing to provide sample for developing the curve, the customer must provide the accurate sample element content and ensure the uniformity of sample, but this curve cannot act as the acceptance index of instrument.

    4. Laboratory environment

    1)Environment requirement

    The instrument must be placed in a special laboratory with an indoor area greater than 10 square meters, and ensure the lab is no harmful, flammable and corrosive gas around.

    Caution: it is forbidden to place this instrument in chemical analysis laboratory.

    Working temperature: 10℃~30℃, and room temperature fluctuation within 3 hours is less than 2 degrees. the laboratory is required to install air conditioning.

    Storage temperature: 0℃~45℃

    Relative humidity of environment: 20% ~ 80%. For wet areas, a dehumidifier is required.

    If not meet the above requirements, the service life and measurement accuracy of the instrument may be will be affected.

    2)Power requirement

    Power supply: single phase 220 + 20V, 1KVA.

    Ensure the normal use of the Innovate NJ-QP880 spectrometer, please install a voltage regulator with 1kVA to 3kVA single phase 220V AC.

    Ensure the reliable use of the instrument, please prepare a single ground wire for the instrument, and the grounding resistance is less than 4 ohms.

    3)Argon requirement

    Purity≥99.999%, oxygen content≤2ppm, H2Ocontent≤5ppm,( The argon gas cylinder cannot be stored in the open air, and the rain is strictly prohibited.)

    If no have high purity argon, it is recommended to use argon purifier.

    Argon gas flow: standby flow approx 0.1L/min, Maintain flow approx(0.4-0.5)L/min, Excitation flow approx 3.5L/min.

    Argon gas controlled pressure: 0.5Mpa.

    4)Argon connection tube

    It is necessary to use the special stainless steel argon connection tube.

    5) Exhaust bottle

    The instrument exhaust gas is discharged through a PVC enhancement tube (14mm inner diameter) into a filter bottle. Need to clean up and replace in time.

    6) Sample preparation

    For iron base samples, the samples must be prepared by special grinding mechanism, a double disc grinding machine and a ground grinder required, which for grinding on the surface of iron and steel samples. The white cast iron sample must be uniformity.

    The user needs to prepare a cutting machine for the treatment of samples which are not suitable for spectroscopic analysis.

    The samples must be uniform, no pores and no casting defects, the surface must be smooth, no oxide, no oil stain and no burrs.

    7) Standard sample requirement

    One standard sample is given at random to correct the overall spectral curve of the instrument, In addition, users need to prepare extra suitable standard samples for their own product types for calibration of instrumental analysis curves.

    8) Computer and printer requirement

    Prepare a computer with conventional configuration, memory 1GB or above, CPU dual core 1.8G Hz or more, to install Innovate T5 spectrometer analysis software.

    Prepare a printer to printing the analysis reports.

    Quality Cmos Signal 220V Ccd Spectrometer , Optical Emission Spectrometer for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: HUATEC GROUP CORPORATION
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more X-ray Pipeline Crawlers products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0