    Automatically Controlled Electric Heat Trace With Fast Reaction

    Ask Lasest Price
    Brand Name : MICH
    Model Number : ACEHTFR
    Certification : ISO9001
    Price : USD0.5-USD5 per meter
    Supply Ability : 10 million meters per year
    Delivery Time : in one month
    • Product Details
    • Company Profile

    Automatically Controlled Electric Heat Trace With Fast Reaction

    Automatically Controlled Electric Heat Trace With Fast Reaction

    Automatically Controlled Electric Heat Trace with Fast Reaction is an electrical heat trace solution based on mineral insulated heating cable element against conventional steam or hot water heat trace. The operation of the electric heat trace system can be controlled in CCR with one button kicking process to start, stop or modify performance of the system. As soon as the button is kicked, the required performance is theoretically achieved soon after that.


    The solution is very simple compared to traditional steam heating or hot water tracing because the product is easy to be laid and operated. While it possesses good property of uniform heating for the media.


    Cable Structure


    Application


    Copper sheathed heating cable (MICU)Maximum output power(W/m)
    Freezing Prevention for metal gutters and downpipes49
    Freezing Prevention for non-metal gutters and downpipes16
    Vessel and piping process temperature maintaining59
    Freezing Prevention for metal containers and pipes59
    Metal roof snow-melting49
    High-density polyethylene outer sheathed copper sheathed heating cable (MIHC)
    Freezing Prevention for metal containers and pipes26
    Freezing Prevention non-metallic containers and pipes13
    Snow melting on asphalt slopes82
    Non-metallic roof ice or snow melting26
    Freezing Prevention for metal gutters and downpipes26
    Freezing Prevention for non - metallic gutters and downpipes16
    Concrete floor heating33
    Rising or defrosting prevention for cold storage ground23
    Freezing Prevention for metal containers and pipes99

    Note: when heating cables are used for heat tracing of vessels and pipes, the maximum output power must be controlled to ensure that the sheath temperature does not exceed its maximum allowable temperature or the spontaneous combustion temperature of the area (for hazardous areas).


    Specification

    Heating cable instruction code


    MI CU-B 16K320/60/2520/220/E1

    No. 1 2 3 4 5 6 7


    No.Instruction
    1Sheath materialCU
    2structure of cable componentsshown in table 1
    3cable codesshown in table 2, 3 and 4
    4length of heating cableIn meter
    5Heating cable powerIn Watt
    6heating cable voltageIn Volt
    7heating cable voltageSee table 5

    Cable Code


    1 6 K 320

    No. 1 2 3 4


    Serial NO.Instruction
    1core number1 or 2
    2Voltage grade3=300V, 6=600V
    3conductor materialsC,K
    4cold resistance ×1000320=0.32Ω/m×1000

    Table 1 Structure of Cable Element


    Note: Model C, F and G are suitable for being used at temperature under 65


    Table 2 Heating Cable Specification (600V Single Conductor)


    Cable CodeDiameterHDPE DiameterStandard resistance value at +20Maximum Production LengthUnit weight
    mmmmΩ/mmkg/km
    16C1.78.2100.0017350366.54
    16C2.27.69.40.0022380307.77
    16C2.97.08.80.0029400264.45
    16C45.97.70.004600190.88
    16C75.37.10.007600154.08
    16C114.96.70.011600132.25
    16C134.66.40.013600 (300)☆125.7
    16C174.66.40.017600 (300)☆117.16
    16C214.66.40.021600 (300)☆111.9
    16C253.75.50.025600 (480)☆68.83
    16C333.75.50.033600 (480)☆63.76
    16C403.45.20.04600 (560)☆58.87
    16C633.250.06360051.47
    16K806.88.60.08370 (140)☆254.18
    16K1005.270.1450 (240)☆162.11
    16K1404.96.70.14600 (270)☆122.55
    16K1974.456.250.197600 (330)☆111.32
    16K2204.56.30.22600 (330)☆102.89
    16K3154.36.10.315600 (350)☆91.44
    16K3454.26.00.345600 (370)☆85.9
    16K4504.05.80.45600 (400)☆80.73
    16K6304.05.80.63600 (400)☆77.26
    16K8003.55.30.8600 (530)☆61.48
    16K12502.84.61.2560040.83
    16K20002.84.62.060038.96

    Table 3 Heating Cable Specification (600V Double Conductors)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    26C3.412.90.0034150783.76
    26C4.412.20.0044160701.56
    26C5.811.30.0058170606.16
    26C8.69.900.0086180451.43
    26C11.49.300.0114200400.05
    26C13.89.000.0138210375.20
    26C17.28.600.0172220344.90
    26C238.000.023250303.25
    26C34.47.500.0344280269.20
    26C49.27.100.0492300243.84
    26K2409.900.24180451.43
    26K3209.300.32200400.05
    26K3849.000.384210375.20
    26K4808.600.48220344.90
    26K6408.000.64250303.25
    26K9607.500.96280269.20

    Table 4 Heating Cable Specification (300V Double Cores)


    Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
    mmΩ/mmkg/km
    23C3.412.00.0034200708.10
    23C4.411.30.0044220629.07
    23C5.810.40.0058240537.73
    23C8.69.000.0086260392.56
    23C11.48.400.0114280343.89
    23C13.88.000.0138300314.57
    23C17.27.600.0172320286.27
    23C237.100.023340252.98
    23C34.46.600.0344360221.19
    23C49.26.200.0492380197.64
    23K16010.40.16220508.37
    23K2409.000.24240392.56
    23K3208.400.32265343.89
    23K3848.000.384280314.57
    23K4807.700.48300291.91
    23K6407.100.64320252.98
    23K9606.500.96350216.11

    Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

    For the use of 660V voltage occasions, please contact our company professionals;

    Mark of (300)☆ is a recommended production length by MICH


    Table 5 terminal specifications


    Model: A, D, EModel: B
    Maximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)Maximum Current (A)Terminal SpecificationMaximum Voltage(V)
    60015E220E115E1
    60020E225E220E1
    60030E340E230E2
    60050E370E250E2
    60070E3100E370E2

    Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

    Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.


    Corresponding reference table between the output power and sheath temperature


    Note: when applying a copper conductor heating cable, please pay attention to the conversion of its heated hot resistance and unheated cold resistance.


    Anticorrosive specification


    Material

    MICU

    MIHC
    SulfateNot recommendExcellent
    Hydrochloric acidNot recommendExcellent
    Hydrofluoric acidAcceptableAcceptable
    PhosphateAcceptableAcceptable
    CarbonateNot recommendAcceptable
    Organic acidAcceptableNot recommend
    Alkali metalAcceptableAcceptable
    Sea waterNot recommendAcceptable
    ChlorideData checking requiredAcceptable

    Explosion-proof instructions


    MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, Ⅱ C (C1D2) level of explosion-proof electrical equipment.


    Quality Automatically Controlled Electric Heat Trace With Fast Reaction for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Pasia Industries Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Electric Heat Tracing products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0