Sign In | Join Free | My burrillandco.com
Home > Other Electrical Equipment >

Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station

    Buy cheap Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station from wholesalers
     
    Buy cheap Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station from wholesalers
    • Buy cheap Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station from wholesalers
    • Buy cheap Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station from wholesalers
    • Buy cheap Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station from wholesalers

    Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station

    Ask Lasest Price
    Brand Name : THOR
    Model Number : TRSW-UHF
    Certification : CE
    Price : Negotiation
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 20000 pieces/month
    Delivery Time : 3-7 work day
    • Product Details
    • Company Profile

    Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station

    The relay base station antenna lightning arrester lightning arrester lightning arrester coaxial antenna

    Working principle of product


    The lightning protection device is based on the principle of standing wave antenna and lightning wave spectrum design. The main part is a short rod equivalent to the end of the 1/4 wavelength. When the signal is sent out, a part of the impedance is reflected back because the impedance is not fully matched, and the wave will form a standing wave when the wave is superimposed on the incident wave originally emitted. The amplitude of standing wave at each point of the line is fixed first. For the transmission line with terminal short circuit, the terminal is short circuited, so the current is large and the voltage is small. For the signal end, the voltage and the current are small.
    That is, the most close to the open circuit of the signal terminal impedance, so the loss is small, but for the lightning wave because of its wide spectrum range, and most of the energy is concentrated in the frequency band below 10HZ, so the short circuit rod is short circuited to the lightning, and will not invade the equipment to cause damage.



    Product features


    1. core components have been strictly screened and selected internationally famous brand products with superior performance.


    2. low capacitance, inductance design, superior transmission performance


    3. the low attenuation coefficient ensures that the lightning arrester does not affect the system


    performance


    Model and specofocation TRSW-BNC
    Frequency range DC-1.5 GHz
    Working voltage 500V
    Nominal discharge currentIn(8/20μS)10kA
    Insulation resistance ≥5000 MΩ
    Dielectric withstanding voltage 1500V
    Impedance 75Ω
    Interface mode BNC.N.UHF.TNC and so on
    Operating condition Temp:-40℃~+70℃
     RH≤95%(25℃)
     Sea level elevation≤3km
    Remarks Other max continuous operating voltage can be customized

    Product introduction


    The lightning protector of antenna feeder is a lightning protection product designed for the antenna feeder system based on the relevant standards. It is suitable for radio communication, mobile base station, microwave communication, radio and television and other coaxial feed signal protection for lightning protection, effectively protecting the damage caused by direct lightning to the equipment.


    Use of attention


    1. identify the input / output interface identifier of the lightning protector, input the external line and output the connection device.


    2. when a signal transmission failure occurs on the line, we should find out the reason. If the lightning protector is damaged, the lightning protector will be changed immediately.


    3. the wire on the lightning arrester is welded to the shortest grounding wire (the wire area is not less than 2.5mm2), the other end is connected to the grounding bus of the lightning protection system, and the grounding resistance is not more than 4 Omega.


    Company profile


    Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support.
    has been designing new products to meet the RoHS directive since 2006. Thor’s ongoing commitment to RoHS compliance includes continuing efforts to reduce the presence of hazardous substances in the design and manufacture of a growing number of popular products.

    Quality Low Capacitance Coaxial Cable Surge Protector Long Service Time For Relay Base Station for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Zhejiang THOR Electric Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Coaxial Cable Surge Protector products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0