Sign In | Join Free | My burrillandco.com
Home > Analyzers >

Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment

    Buy cheap Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment from wholesalers
     
    Buy cheap Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment from wholesalers
    • Buy cheap Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment from wholesalers
    • Buy cheap Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment from wholesalers
    • Buy cheap Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment from wholesalers

    Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : P10.1
    Certification : CE, ISO
    Price : Negotiable
    Payment Terms : T/T
    Delivery Time : 1-45 work days
    • Product Details
    • Company Profile

    Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment

    Membrane-Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment Applications


    The two-electrode system membrane peracetic acid sensor P10.1 is used in all water treatments. It has a mechanically sturdy membrane system with high tolerance to chemicals. The maximum water temperature is 45°C. The optional range is 0~20/200/2000/5000/20000/50000 ppm. Its main features and advantages include the following:

    Features


    1. Simple two-electrode structure:
    Contains working electrode and reference electrode, compact design, easy to integrate into equipment or system.
    Reduces complex interactions between electrodes and improves signal stability.


    2. Selective detection:
    Isolates other interfering substances through membrane technology to achieve specific detection of peracetic acid.
    Provides a stable background signal to avoid cross-interference.


    3. Fast response time:
    The high mass transfer rate of the membrane enables the sensor to respond quickly to changes in peracetic acid concentration.


    4. Low maintenance requirements:
    The protective effect of the membrane reduces electrode contamination and loss, extending the service life of the sensor.
    Usually has automatic calibration and self-cleaning functions for daily use.


    5. Wide measurement range:
    It can detect peracetic acid from low concentration (ppm level) to high concentration, meeting various application requirements.


    Advantages
    1. High precision and stability:
    The membrane method effectively reduces external interference and improves the accuracy and long-term stability of detection.


    2. Chemical corrosion resistance:
    The sensor material is usually made of corrosion-resistant materials to adapt to the strong oxidizing environment of peracetic acid and other disinfectants.


    3. Low power consumption design:
    The two-electrode system has a simple design and low energy consumption, which is suitable for continuous online monitoring.


    4. Easy to install and operate on site:
    The miniaturized design and plug-and-play function make it easy to deploy under various field conditions.


    5. Flexible data output:
    Supports multiple signal output methods (such as analog signal 4-20mA or digital communication protocol), which is easy to integrate with the control system.


    6. Strong adaptability:
    It can be used in different water quality conditions (such as sewage, drinking water, industrial water), and has strong tolerance to flow rate and pressure changes.


    Specifications


    P10.1

    IndicatorPeracetic acid

    Application

    All kinds of water treatment, also sea water

    Conductivity acids are tolerated.

    (e. g. bottle washing machine, CIP-plants)

    The membrane system is mechanical resistant.

    The membrane system is highly resistant to surfactants (tensides).

    Measuring systemMembrane covered, amperometric 2-electrode system

    Electronics

    Analog version: - voltage output

    - not galvanically isolated electronics

    - analog internal data processing

    - output signal: analog (analog-out/analog)

    Digital version: - electronic is completely galvanically isolated

    - digital internal data processing

    - output signal: analog (analog-out/digital)

    or

    digital (digital-out/digital)

    mA-version: - current output analog

    - not galvanically isolated electronics

    - output signal: analog (analog-out/analog)


    Information about the measuring range

    The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

    Note: With a slope > 100% the measuring range is reduced accordingly.

    (Ex.: 150% slope → 67% of the specified measuring range)

    Accuracy

    After calibration at repeat conditions (25 °C, in drinking water) from full scale value

    Measuring range 2000 mg/L: at 400 mg/l <2%

    at 1600 mg/l <3%


    Working temperature

    Measuring water temperature: 0 … +45 °C

    (no ice crystals in the measuring water)

    Ambient temperature: 0 … +55 °C
    Temperature compensation

    Automatically, by an integrated temperature sensor

    sudden temperature changes must be avoided

    Response time t90: approx. 8 min.


    Max. allowed working pressure

    Operation without retaining ring:

    - 0.5 bar

    - no pressure impulses and/or vibrations

    Operation with retaining ring in flow cell:

    - 1.0 bar,

    - no pressure impulses and/or vibrations (see option 1)



    P10.1

    Flow rate (Incoming flow velocity)Approx. 15-30L/h (33 – 66 cm/s) in flow cell, small flow rate dependence is given
    pH-rangepH 1 – pH 8 (see Diagram “Slope of TARAtec P9.3 and P10.1 versus pH“, page 8)

    Run-in time

    Measuring range 200 mg/L: First start-up approx. 3 h

    Measuring range 2000 mg/L: First start-up approx. 1 h

    Measuring range 20000 mg/L: First start-up approx. 30 min.

    Response time

    T90: approx. 3.5 min. at 10 °C

    T90: approx. 1.5 min. at 45 °C

    Zero point adjustmentNot necessary
    CalibrationAt the device, by analytical determination

    Interferences

    O3: increases the measured value strongly

    ClO2: increases the measured value

    H2O2: very low influence on the measuring value (reduction of the PAA-signal)

    Influence of conductivity acids1 % sulfuric acid, 1 % nitric acid or 1 % phosphoric acid in the water have no influence to the measuring behaviour
    Absence of the disinfectantMax. 24 h

    Connection

    mV version: 5-pole M12, plug-on flange

    Modbus version: 5-pole M12, plug-on flange

    4-20 mA version: 2-pole terminal or

    5-pole M12, plug-on flange

    Max. length of sensor cable

    (depending on internal signal processing)

    Analog< 30 m
    Digital

    > 30 m are permissible

    Maximum cable length depends on application

    Protection type

    5-pole M12 plug-on flange: IP68

    2-pole terminal with mA-hood: IP65

    MaterialElastomer membrane, PVC-U, stainless steel 1.4571

    Size

    Diameter: approx. 25 mm

    Length: mV version approx. 190 mm (analog signal processing)

    approx.. 205 mm (digital signal processing)

    Modbus version approx. 205 mm

    4-20 mA version approx. 220 mm (2-pole-terminal)

    approx. 190 mm (5-pole-M12)

    Transport+5 … +50 °C (Sensor, electrolyte, membrane cap)



    P10.1


    Storage

    Sensor: dry and without electrolyte no limit at +5 … +40 °C

    Electrolyte: in original bottle protected from sunlight at +5 … +35 °C

    min. 1 year or until specified EXP-Date

    Membrane cap: in original packing no limit at +5 … +40 °C

    (used membrane caps cannot be stored)


    Maintenance

    Regular control of the measuring signal, min. once a week

    The following specifications depend on the water quality:

    Change of the membrane cap: once a year

    Change of the electrolyte: every 3 - 6 months



    Option 1: Retaining ring

    - When operating with pressures >0.5 bar in flow cell

    - Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

    - Different positions for groove selectable (on request)



    Technical Data

    1. P10.1 (Analog output, analog internal signal processing)

    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanic.



    Measuring rangeResolutionOutput Output resistanceNominal slopeVoltage supplyConnection

    P10.1-20-M12

    0…20 ppm

    0,01 ppm

    0…-2000 mV


    1 kΩ

    -100 mV/ppm

    ±5 - ±15 VDC


    10 mA

    Function of wires:

    PIN1: measuring signal

    PIN2: +U

    PIN3: -U

    PIN4: signal GND

    P10.1H-M120…200 ppm0.1 ppm-10 mV/ppm

    P10.1N-M12

    5…2000 ppm

    1 ppm

    -1 mV/ppm

    P10.1L-M120.005…2 % (20000 ppm)

    0.001 %

    (10 ppm)

    -1000mV/%

    (-0.1 mV/ppm)

    P10.1Up2000-M125…2000 ppm1 ppm

    0…+2000 mV

    1 kΩ

    +1 mV/ppm

    10 - 30 VDC

    10 mA

    5-pole M12 plug-on flange

    Function of wires:

    PIN1: measuring signal PIN2: +U

    PIN3: power GND

    PIN4: signal GND

    PIN5: n. c.

    P10.1Up5000-M12

    50…5000 ppm

    1 ppm

    +0.4 mV/ppm

    (Subject to technical changes.)

    2. P10.1 (analog output, digital internal signal processing)

    analog-out / digital

    - The power supply is galvanically isolated inside of the sensor.

    - The output signal is galvanically isolated too, that means potential-free.


    Measuring rangeResolutionOutput Output resistanceNominal SlopePower supplyConnection
    P10.1-20- An-M120…20 ppm0,01 ppm

    analog 0…-2 V

    (max. -2.5 V)

    -100 mV/ppm

    9-30 VDC

    approx. 20-56 mA

    5-pole M12 plug-on flange


    Function of wires:

    PIN1: measuring signal PIN2: +U

    PIN3: power GND

    PIN4: signal GND

    P10.1H-An-M120…200 ppm0.1 ppm-10 mV/ppm
    P10.1N-An-M125…2000 ppm1 ppm-1 mV/ppm
    P10.1L-An-M120.005…2% (20000 ppm)

    0.001%

    (10 ppm)

    -1000 mV/%

    (-0.1 mV/ppm)

    P10.1-20- Ap-M120…20 ppm0,01 ppm

    analog 0…+2 V

    (max. +2.5 V)

    -100 mV/ppm
    P10.1H-Ap-M120…200 ppm0.1 ppm+10 mV/ppm
    P10.1N-Ap-M125…2000 ppm1 ppm+1 mV/ppm
    P10.1L-Ap-M120.005…2% (20000 ppm)

    0.001%

    (10 ppm)

    +1000 mV/%

    (+0.1 mV/ppm)


    (Subject to technical changes.)

    3. P10.1 (digital output, digital internal signal processing)

    - The power supply is galvanically isolated inside of the sensor.

    - The output signal is galvanically isolated too, that means potential-free.



    Measuring rangeResolution

    Output

    Output resistance

    Power supplyConnection

    P10.1-20- M0c


    0…20 ppm


    0,01 ppm

    Modbus RTU

    There are no terminating resistors in the sensor.

    9-30 VDC

    5-pole M12 plug-on flange

    Function of wires:

    PIN1: reserved

    PIN2: +U

    PIN3: power GND

    PIN4: RS485B

    PIN5: RS485A

    P10.1H-M0c0…200 ppm0.1 ppm
    P10.1N-M0c5…2000 ppm1 ppm

    P10.1L-M0c

    0.005…2% (20000 ppm)

    0.001%

    (10 ppm)

    (Subject to technical changes.)

    4. P10.1 4-20 mA (analog output, analog internal signal processing)

    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanic.

    4.1 Electrical connection: 2 pole terminal clamp


    Measuring rangeResolutionOutput Output resistanceNominal slopeVoltage supplyConnection
    P10.1MA200…20 ppm0,01 ppm

    4…20 mA uncalibrated

    0,8 mA/ppm

    12…30 VDC


    RL = 50Ω (12V) RL 900Ω (30V)

    2-pole terminal

    (2 x 1 mm²)


    Recommended:

    Round cable

    φ4 mm

    P10.1MA-2000…200 ppm0.1 ppm0.08 mA/ppm
    P10.1MA-5005…500 ppm1 ppm0.032 mA/ppm
    P10.1MA-20005…2000 ppm1 ppm0.008 mA/ppm
    P10.1MA-500050…5000 ppm1 ppm0.0032 mA/ppm
    P10.1MA-2%0.005…2 %
    (20000 ppm)
    0.001 %
    (10 ppm)

    8.0 mA/%

    (0.0008 mA/ppm)

    P10.1MA-5%0.05…5 %
    (50000 ppm)
    0.01 %
    (100 ppm)

    3.2 mA/%

    (0.00032 mA/ppm)

    (Subject to technical changes.)

    4.2 Electrical connection: 5 pole M12 plug-on flange


    Measuring rangeResolutionOutput Output resistanceNominal slopeVoltage supplyConnection
    P10.1MA20-M120…20 ppm0,01 ppm

    4…20 mA uncalibrated

    0,8 mA/ppm

    12…30 VDC


    RL = 50Ω (12V) … RL 900Ω (30V)

    5-pole M12 plug- on flange


    Function of wires:

    PIN1: n. c.

    PIN2: +U

    PIN3: -U

    PIN4: n c.

    P10.1MA-200-M120…200 ppm0.1 ppm0.08 mA/ppm
    P10.1MA-500-M125…500 ppm1 ppm0.032 mA/ppm
    P10.1MA-2000-M125…2000 ppm1 ppm0.008 mA/ppm
    P10.1MA-5000-M1250…5000 ppm1 ppm0.0032 mA/ppm
    P10.1MA-2%-M120.005…2 %
    (20000 ppm)
    0.001 %
    (10 ppm)

    8.0 mA/%

    (0.0008 mA/ppm)

    P10.1MA-5%-M120.05…5 %
    (50000 ppm)
    0.01 %
    (100 ppm)

    3.2 mA/%

    (0.00032 mA/ppm)

    (Subject to technical changes.)


    Spare Parts


    TypeMembrane capElectrolyteEmeryO-ring

    P10.1

    not: - P10.1L

    - P10.1MA-2%

    - P10.1MA-5%

    M10.3N
    Art. no. 11057

    EPS9H/W, 100 ml

    Art. no. 11025

    S2
    Art. no. 11906
    20 x 1.5 silicone
    Art. no. 11803

    P10.1L

    P10.1MA-2%

    P10.1MA-5%

    EPS9L/W, 100 ml

    Art. no. 11024

    (Subject to technical changes.)

    Quality Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All Water Treatment for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Disinfectant Analyzer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0