Sign In | Join Free | My burrillandco.com
Home > Used Measuring & Analysing Instruments >

Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals

    Buy cheap Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals from wholesalers
     
    Buy cheap Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals from wholesalers
    • Buy cheap Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals from wholesalers
    • Buy cheap Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals from wholesalers
    • Buy cheap Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals from wholesalers

    Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals

    Ask Lasest Price
    Brand Name : Daruifuno
    Model Number : P9.3
    Certification : CE, ISO
    Price : Negotiable
    Payment Terms : T/T
    Delivery Time : 1-45 work days
    • Product Details
    • Company Profile

    Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals

    Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals


    The dual-electrode system membrane peracetic acid sensor P9.3 is used in all water treatments. It has a mechanically sturdy membrane system, is resistant to surfactants, and has high tolerance to chemicals. The maximum water temperature is 60°C, and the optional range is 0~200/2000/20000 ppm.


    It is a high-performance monitoring device for water treatment. Its design and process characteristics enable it to perform well in a variety of application scenarios. The following are its detailed process characteristics and advantages:


    Process characteristics


    Dual-electrode system design
    Working electrode and reference electrode:
    Provide stable and accurate signals through the dual-electrode system to ensure high-precision peracetic acid detection.
    Signal stability: The electrode configuration effectively reduces noise and background interference.


    Membrane separation technology
    Selective permeable membrane: The sensor surface is covered with a selective membrane that allows peracetic acid molecules to pass through while shielding interfering substances
    Enhanced durability: Protect the electrode, reduce chemical loss, and extend the service life of the equipment.


    Chemical corrosion resistance
    The material is selected with high chemical corrosion resistance, which can withstand complex chemical environments and is suitable for a variety of water treatment scenarios, such as industrial wastewater and highly polluted water monitoring.


    Real-time online monitoring
    The sensor can be directly connected to the automated monitoring system to achieve continuous monitoring and dynamic adjustment of the water treatment process.


    Automatic temperature compensation
    The built-in temperature compensation function provides consistent test results under different water temperature conditions.


    Advantages
    High precision and sensitivity
    The detection accuracy of low-concentration peracetic acid is high, which is suitable for scenarios with strict water quality requirements.


    Strong anti-interference ability
    The selective membrane effectively reduces the interference of other chemicals and ensures the accuracy of the measurement data.


    Low maintenance requirements
    The sensor diaphragm is durable and easy to replace, the equipment design is simple, and the maintenance cost is low.
    The automatic calibration function reduces the frequency of manual operation.


    Fast response
    The response time is short, and it can quickly capture water quality changes and provide timely feedback for water treatment process adjustments.


    Environmental protection and safety
    No reagents are required, which reduces the generation of chemical waste and is environmentally friendly.


    Long-term stability
    High-tolerance materials and membrane design ensure the reliability and stability of the equipment during long-term operation.



    Specifications




    P9.3

    IndicatorPeracetic acid

    Application

    All kinds of water treatment

    Tensides and conductivity acids are tolerated

    (e. g. bottle washing machine, CIP-plants)

    Measuring systemMembrane covered, amperometric 2-electrode system

    Electronic

    Analog version: - voltage output

    - not galvanically isolated electronics

    - analog internal data processing

    - output signal: analog (analog-out/analog)

    Digital version: - electronic is completely galvanically isolated

    - digital internal data processing

    - output signal: analog (analog-out/digital)

    or

    digital (digital-out/digital)

    mA-version: - current output analog

    - not galvanically isolated electronics

    - output signal: analog (analog-out/analog)


    Information about the measuring range

    The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope


    Note: With a slope > 100% the measuring range is reduced accordingly.

    (Ex.: 150% slope → 67% of the specified measuring range)

    Accuracy

    After calibration at repeat conditions (25 °C, in drinking water) from full scale value

    Measuring range 2000 mg/L: at 400 mg/l <2%

    at 1600 mg/l <3%


    Working temperature

    Measuring water temperature: 0 … +60 °C

    (no ice crystals in the measuring water)

    Ambient temperature: 0 … +55 °C
    Temperature compensation

    Automatically, by an integrated temperature sensor sudden temperature

    changes must be avoided

    T90: approx. 3.5 min.


    Max. allowed working pressure

    Operation without retaining ring:

    – 0.5 bar

    – no pressure impulses and/or vibrations

    Operation with retaining ring in flow cell

    – 1.0 bar,

    – no pressure impulses and/or vibrations

    (see option 1)

    Flow rate

    (Incoming flow velocity)

    approx. 15-30L/h (33 – 66 cm/s) in flow cell, small flow rate dependence is given
    pH-rangepH 1 – pH 8 (see Diagram „Slope of P9.3 and P10.1 versus pH“, p. 8)




    P9.3


    Run-in time

    Measuring range 200 mg/L: First start-up approx. 3 h

    Measuring range 2000 mg/L: First start-up approx. 1 h

    Measuring range 20000 mg/L: First start-up approx. 30 min.

    Response time

    T90: approx. 3.5 min. at 10 °C a

    pprox. 45 sec. at 50 °C

    Zero point adjustmentNot necessary
    CalibrationAt the device, by analytical determination

    Interferences

    O3: high increase of the measuring value

    ClO2: increases the measuring value

    H2O2: very low influence on the measuring value (reduce of the PAA-signal)

    Influence of conductivity acids

    1 % sulfuric acid, 1 % nitric acid or 1 % phosphoric acid in the water have no

    influence to the measuring behaviour

    Absence of the disinfectantMax. 24 h

    Connection

    mV version: 5-pole M12, plug-on flange

    Modbus version: 5-pole M12, plug-on flange

    4-20 mA version: 2-pole terminal or

    5-pole M12, plug-on flange

    Max. length of sensor cable

    (depending on internal signal processing)

    Analog< 30 m
    Digital

    > 30 m are permissible

    Maximum cable length depends on application

    Protection type

    5-pole M12 plug-on flange: IP68

    2-pole terminal with mA-hood: IP65

    MaterialElastomer membrane, PEEK, stainless steel 1.4571

    Size

    Diameter: approx. 25 mm

    Length: mV version approx. 190 mm (analog signal processing)

    approx.. 205 mm (digital signal processing)

    Modbus version approx. 205 mm

    4-20 mA version approx. 220 mm (2-pole-terminal)

    approx. 190 mm (5-pole-M12)

    Transport+5 … +50 °C (Sensor, electrolyte, membrane cap)




    P9.3

    Storage

    Sensor: dry and without electrolyte no limit at +5 … +40 °C

    Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min. 1

    year or until specified EXP-Date

    Membrane cap: in original packing no limit at +5 … +40 °C

    (used membrane caps cannot be stored)


    Maintenance

    Regularly control of the measuring signal, min. once a week

    The following specifications depend on the water quality:

    Change of the membrane cap: once a year

    Change of the electrolyte: every 3 - 6 months




    Option 1:

    Retaining ring

    – When operating with pressures >0.5 bar in flow cell

    – Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP

    – Different positions for groove selectable

    (on request)


    Technical Data

    1. P9.3 (Analog output, analog internal signal processing)

    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanic.

    Measuring rangeResolutionOutput Output resistanceNominal slopeVoltage supplyConnection

    P9.3H-M12

    0…200 ppm

    0.1 ppm

    0…-2000 mV


    1 kΩ


    -10 mV/ppm

    ±5 - ±15 VDC

    10 mA

    5-pole M12 plug-on flange

    Function of wires:

    PIN1: measuring signal

    PIN2: +U

    PIN3: -U

    PIN4: signal GND

    PIN5: n. c.

    P9.3N-M12

    5…2000 ppm

    1 ppm


    -1 mV/ppm

    P9.3L-M12

    0.005…2 % (20000 ppm)

    0.001 %

    (10 ppm)

    -1000mV/%

    (-0.1 mV/ppm)

    P9.3Up2000-M125…2000 ppm1 ppm

    0…+2000 mV


    1 kΩ

    +1 mV/ppm

    10 - 30 VDC

    10 mA

    5-pole M12 plug-on flange

    Function of wires: PIN1: measuring signal PIN2: +U

    PIN3: power GND PIN4: signal GND PIN5: n. c.

    P9.3Up5000-M12

    50…5000 ppm

    1 ppm

    +0.4 mV/ppm

    (Subject to technical changes.)


    2. P9.3 (analog output, digital internal signal processing)

    analog-out / digital

    - The power supply is galvanically isolated inside of the sensor.

    - The output signal is galvanically isolated too, that means potential-free.


    Measuring rangeResolution

    Output

    Output resistance

    Nominal slopeVoltage supplyConnection
    P9.3H-An-M120 … 200 ppm0.1 ppm

    analog

    0…-2 V

    (max. -2.5 V)

    1 kΩ

    -10 mV/ppm

    9-30 VDC


    approx. 20-56 mA

    5-pole M12 plug-on flange


    Function of wires:

    PIN1: measuring signal

    PIN2: +U

    PIN3: power GND PIN4: signal GND PIN5: n. c.

    P9.3N-An-M125 … 2000 ppm1 ppm-1 mV/ppm
    P9.3L-An-M12

    0.005 … 2 %

    (20000 pm)

    0.001 %

    (10 ppm)

    -1000mV/%

    (-0.1 mV/ppm)

    P9.3H-Ap-M120 … 200 ppm0.1 ppm

    analog

    0…+2 V

    (max. +2.5 V)

    1 kΩ

    +10 mV/ppm
    P9.3N-Ap-M125 … 2000 ppm1 ppm+1 mV/ppm
    P9.3L-Ap-M12

    0.005 … 2 %

    (20000 pm)

    0.001 %

    (10 ppm)

    +1000mV/%

    (+0.1 mV/ppm)

    (Subject to technical changes.)

    3. P9.3 (digital output, digital internal signal processing)

    - The power supply is galvanically isolated inside of the sensor.

    - The output signal is galvanically isolated too, that means potential-free.

    Measuring rangeResolution

    Output

    Output resistance

    Voltage supplyConnection

    P9.3H-M0c


    0 … 200 ppm


    0.1 ppm

    Modbus RTU


    There are no terminating resistors in the sensor.

    9-30 VDC


    approx. 20-56 mA

    5-pole M12 plug-on flange

    Function of wires: PIN1: reserved

    PIN2: +U

    PIN3: power GND

    PIN4: RS485B

    PIN5: RS485A


    P9.3N-M0c


    5 … 2000 ppm


    1 ppm


    P9.3L-M0c

    0.005 … 2 %

    (20000 pm)

    0.001 %

    (10 ppm)

    (Subject to technical changes.)


    4. P9.3 4-20 mA (analog output, analog internal signal processing)

    A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanic.

    4.1 Electrical connection: 2 pole terminal clamp


    Measuring rangeResolutionOutput Output resistanceNominal slopeVoltage supplyConnection
    P9.3MA-2000 … 200 ppm0.1 ppm

    4…20 mA uncalibrated

    0.08 mA/ppm

    12…30 VDC

    RL = 50Ω (12V)… 900Ω (30V)

    2-pole terminal (2 x 1 mm²)

    Recommended: Round cableØ 4 mm

    2 x 0.34 mm²

    P9.3MA-20005 … 2000 ppm1 ppm0.008 mA/ppm
    P9.3MA-2%

    0.005 … 2 %

    (20000 ppm)

    0.001 %

    (10 ppm)

    8.0 mA/%

    (0.0008 mA/ppm)

    (Subject to technical changes.)


    4.2 Electrical connection: 5 pole M12 plug-on flange


    Measuring rangeResolutionOutput Output resistanceNominal slopeVoltage supplyConnection

    P9.3MA-200-M12


    0 … 200 ppm


    0.1 ppm


    4…20 mA
    uncalibrated

    0.08 mA/ppm


    12…30 VDC
    RL = 50Ω
    (12V)… 900Ω (30V)

    5-pole M12 plug- on flange


    Function of wires:

    PIN1: n. c.
    PIN2: +U
    PIN3: -U

    PIN4: n c.

    PIN5: n. c.

    P9.3MA-2000-M125 … 2000 ppm1 ppm0.008 mA/ppm

    P9.3MA-2%-M12

    0.005 … 2 %

    (20000 ppm)


    0.001 %

    (10 ppm)

    8.0 mA/%

    (0.0008 mA/ppm)

    (Subject to technical changes.)

    Spare Parts

    TypeMembrane capElectrolyteEmeryO-ring

    P9.3

    not P9.3L

    and P9.3MA-2%

    M9.3N


    Art. no. 11058

    EPS9H/W, 100 ml

    Art. no. 11025

    S2

    Art. no. 11906

    20 x 1.5 silicone

    Art. no.. 11803

    P9.3L

    P9.3MA-2%

    EPS9L/W, 100 ml
    Art. no. 11024

    (Subject to technical changes.)


    Solope of P9.3 and P10.1 versus pH

    Quality Two-Electrode System Peracetic Acid Sensor For All Water Treatments High Tolerance To Chemicals for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Suzhou Delfino Environmental Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Disinfectant Analyzer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0