Sign In | Join Free | My burrillandco.com
Home >

GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices

    Buy cheap GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices from wholesalers
     
    Buy cheap GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices from wholesalers
    • Buy cheap GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices from wholesalers
    • Buy cheap GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices from wholesalers
    • Buy cheap GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices from wholesalers
    • Buy cheap GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices from wholesalers

    GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices

    Ask Lasest Price
    Brand Name : GE
    Model Number : N216-8E-SHG 0061725
    Price : USD
    Payment Terms : T/T, Western Union,PayPal
    Supply Ability : In stock
    Delivery Time : 3-5 working days
    MOQ : 1 Piece
    • Product Details
    • Company Profile

    GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices

    GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 Used in Good Working Hospital Devices


    ► Brief Introduction


    The thermal print head temperature monitor measures the temperature of the heating head located on the print head. If the thermal print head temperature is too high, the signal REC_OVHEAT is activated and the signal STROBE is disabled to prevent the print head from heating up.

    As the print head temperature increases, the heating time is reduced, thus maintaining normal font over the entire temperature range.

    When the print head temperature drops below 50°C, the signal REC_OVHEAT_ is disabled and the heating is re-enabled by the signal STROBE.


    Specifications


    Brand nameGE
    Part NumberN216-8E-SHG 0061725
    Product NameThermal Print Head
    Product CategoryMac1200 ECG Machine
    TypeSpare parts
    MOQ1 Piece
    Payment TermsFull Before Shipment
    Warranty90 Days
    Delivery3-5 Working Days
    ConditionUsed in Good Working
    Delivery MethodDHL ,Fedex ,UPS
    Paypal MethodPaypal,T/T,Western Union
    Power Supply SourceElectric
    InventoryIn stock
    PackingCarton
    Method of TransportExpressage
    Product EdgeOriginal,Advanced equipment
    ApplicationMedical Equipment,ICU,Hospital Device


    ►Safety Information


    Warning

    1. All installation, expansion, changes, modifications and maintenance of this product must be performed by Mindray authorized personnel.

    2. High voltages are present inside the device. Do not remove the power supply or battery before disassembling the device.

    3. When removing/reinstalling the parameter module, a patient leakage current test must be performed before it can be reused for monitoring.

    4. The device must be connected to a properly installed outlet with only one protective ground. If your unit does not have a protective ground, disconnect it from the power cord and use battery power if possible.

    5. Dispose of packaging materials in accordance with local waste regulations and keep out of the reach of children.


    ► Cleaning


    To prevent wear and damage to the thermal head and ensure optimal performance and a long lifespan, clean the head surface with the provided thermal head cleaning pen after recording every 10 sets of paper.


    1.Turn off the electrocardiograph before cleaning the thermal head.

    2.Press the paper tray release button to open the paper tray.

    3.Use the thermal head cleaning pen to clean the gray area of ​​the thermal head.


    Any inquiry about GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 Used in Good Working Hospital Devices, Medical Device Hospital Equipment​ will be highly appreciated and thanks for your support.


    Quality GE Mac1200 ECG Machine Thermal Print Head SHEC N216-8E-SHG 0061725 In Hospital Devices for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: China World Technology Medical Equipment Service Group
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more ECG Machine Parts products from this supplier
    Inquiry Cart 0