Sign In | Join Free | My burrillandco.com
Home > Measuring & Analysing Instrument Processing Services >

SAE-J1211 335L Stress Screening Environmental Test Chambers

    Buy cheap SAE-J1211 335L Stress Screening Environmental Test Chambers from wholesalers
     
    Buy cheap SAE-J1211 335L Stress Screening Environmental Test Chambers from wholesalers
    • Buy cheap SAE-J1211 335L Stress Screening Environmental Test Chambers from wholesalers
    • Buy cheap SAE-J1211 335L Stress Screening Environmental Test Chambers from wholesalers
    • Buy cheap SAE-J1211 335L Stress Screening Environmental Test Chambers from wholesalers

    SAE-J1211 335L Stress Screening Environmental Test Chambers

    Ask Lasest Price
    Brand Name : Envsin
    Model Number : ETS6340S3
    Certification : CE and ISO
    Price : To Be Negotiated
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 25 per month
    Delivery Time : 30-35 business days after received the payment
    • Product Details
    • Company Profile

    SAE-J1211 335L Stress Screening Environmental Test Chambers

    335L Environmental Stress Screening Test Chambers Water-Cooled Climatic Test Chamber


    The chamber used to test samples of non-heat dissipation or low heat dissipation. For test specimen with heat dissipation, the heat dissipating power can not exceed the cooling capacity of refrigeration system, otherwise it will affect the chamber temperature conversion speed and capacity. It is proposed test sample’s heat is less than 300W.


    Products Tech Specification(Feature):

    Test Space

    335L

    Internal size

    800*650*650mm(W×D×H)

    External size

    1800mm*2500mm*2300mm (W*D*H)

    Power supply

    AC380V±10%,50Hz±1 four wire three phase+ earth wire(3/N/PE),Earthing resistance<4Ω

    Max. Power

    65KW

    Max. Currency

    110A

    Cooling Method

    Water-Cooled

    System structure

    Three part structure:immobile independent test area.Preheating area. Precooling area

    Installation Site

    • No strong electromagnetic radiation source nearby
    • Close to drainage system ( within 2 meters to refrigeration unit,for condensate water)
    • The ground bearing capacity not less than 20000kg/m2
    • Prepare proper power supply and water supply
    • If need water or gas supply, should be equipped with in advance
    • Ambient Temp: 5℃~25℃suggested, 25℃~35℃ function well;(for air-cooled model);5℃~40℃ function well (for water-cooled model)
    • Ambient Humid:≤85%RH;
    • Ambient Pressure:86KPa~106KPa;
    • Installation space assurances, as following

    A:100cm

    B:80cm

    C:150cm

    D:80cm

    E:60cm

    Cooling water

    Water Temp:5℃≤Water Temp≤28℃ reach all technical index, 28℃<Water Temp≤33℃ function well(cooling time will change);

    Water source Temp ≤10℃,need to prevent condensate water arise

    1:If test chamber adopt air-cooled,no need cooling water


    2: If user need build cooling cycle water system, cooling tower specification≥15 ton or condensing unit refrigerating capacity≥40KW(20℃)


    3:Cooling water system should be GB50050-1995 industrial cycling cooling water treatment design regulation standard

    Water flow:≥15 ton/h

    Pipe diameter:G2.5 inches ×2

    hydraulic pressure:0.3MPa~0.6MPa

    Hydraulic Pressure Difference:≥0.2MPa

    Water quality requirement:GB50050-1995

    Air compression

    Compressed air supply pressure:0.6MPa~0.7MPa

    Humidity of compressed air under Pneumatic use:≤30g/m³

    Humidity of compressed air under dry air use:≤1.5g/m³


    Specifications:

    Working chamber temp shock test parameter

    Thermal Shock Test Chambers--S2:

    • Low-temp shock range:﹣55℃~﹣10℃
    • High-temp shock range:+60℃~+150℃

    Low-High+Room Temperature Shock Test Chamber-S3:

    • Low-temp shock range:﹣65℃~﹣10℃
    • High-temp shock range: +60℃~+150℃
    • PAMP Environmental Stress Screening
    • Low Temp. Range:﹣55℃~﹣10℃
    • High Temp. Range: +60℃~+125℃
    • Temp. Gradient:3~30℃/min
    • Temp. Fluctuation:±0.1℃~±1.0℃
    • Temp. Uniformity:±0.5℃~±2.0℃
    • Temp Deviation:<±2℃

    Note:

    1.Testing with no load, meeting GB/T5170-2008, if no other special notice.


    2.Temp. range in 0℃~+60℃, setting Shock temp. and RAMP Environmental Stress Screening function are disapprove.


    3. Air cooled test chamber test data at Ambient Temp. 25℃, good ventilation condition;35℃≥RT>25℃ function well; low temp range, cooling rate and thermal load capacity will be affected by the changeable environment temperature.


    4.Water cooled test chamber test data at water temp ≤28℃, Hydraulic pressure 0.3MPa~0.6Mpa, Hydraulic Pressure Difference≥0.2Mpa

    Preheat temp.

    Temp. SV: +50℃~+220℃

    Temp rise time: RT→+220℃ 50min

    Precool temp.

    Temp. PV:﹣75℃~+70℃

    Temp. reduction time: RT-75℃ 60min

    Temp. recovery time

    <15min(measure in air outlet)

    Test standard


    Experiment standard-S2:

    GB/T2423.22

    MIL STD 202F, method 107G

    IEC 60068-2-14, Test Na

    BS 2011

    DIN 40046, Test Na

    JESD22-A101-A

    Experiment standard-S3:

    GJB 150.5-1986

    MIL STD 883H

    MIL STD 202G

    IEC 60068-2-14

    JIS C 60068-2-14

    JASO D 014–4

    EIA JED-2531A

    Environmental Stress Screening Test Standard:

    IEC 60749-25(JESD22-A104D)

    IEC 60068-2-14NB(JIS C0025NB)

    IEC 61747-5(EIA JED-2531A)

    JESD22-A105-B

    IPC-9701

    SAE-J1211

    1.Chamber door

    2.Observation window

    3. Control Pad

    4. Preheat area

    5. Working Lights

    6. Cable port

    7. Precooling area

    8.Extensional control pad

    9.Power distribution board

    10.Refrigeration unit room

    Quality SAE-J1211 335L Stress Screening Environmental Test Chambers for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Envsin Instrument Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Climatic Test Chamber products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0